Installation Instructions
265 VOLT ELECTRICAL SUPPLY
./k WARNING:
Connection of this 965 V AC product to a branch circuit
MUST be done b) direct connection in accordance with
the National Electrical Code. Plugging this unit into a
building mounted exposed receptacle is not permitted
b) code.
These inodels must be installed using the api)ropriate
GE power supi)l } kit tor the branch circuit amperage
and the electrical resistance heater wattage desired.
Use the POWER CONNECTION CHART on page 17
to determine the correct kit required. One of the
fl)llowing installation methods (A or B) must be used.
HOW TO CONNECT
1Remove the room cabinet.
2Connect to electrical power,
3See the special instructions below fi}r applicable
supply voltages.
4 Reinstall the room cabinet.
A. FOR SUBBASE INSTALLATION
Electrical subbase kits are a_ailable to provide a flexible
enclosure fi)r direct connection,
Branch Circuit and Proper GE Power
UnitAmperage Bating Suhhase Kit Supply Kit
15 ILM_204E 15 ILM(5172
20 IL_K204E20 I,L_K5202
30 IL_K204E30 I,L_K5302
The instructions pr{wided wifll the selected subba_ kit must
be cm'efifl b tbllo_vvd. It is the responsibilit) of the installer
to ensure the connection of COlnponents is done in
accordance with these insu ucfions and all elecu'ical codes.
B. FOR DIRECT CONNECT
INSTALLATION
If an electrical subbase is not used, direct connection to
branch circuit wiring inside the provided junction box must
be done in accordance with the following steps.
[] REMOVE JUNCTION BOX
1 Remo_e the junction box co_er b) remoqng the
_]'ont tv_o s(rev_s.
2 Remo_e the junction box b) removing the top and
bottom rear scre_s. Note ho_ the tabs on the lo_er
lett side of the junction box ser_e to hold the side in
place. This will help Mien the box is being reinstalled.
Unit connector
Junction Junction
boxcover box
[] CUT AND STRIP THE CORDSET
1Remove the cordset ti'om the power supply kit.
Measure G" down the cord fl'om where it elnerges
fix)in the back of the nylon plastic connector
and cut the cord through at this point.
2 Carefully remove 3" of the cordset insulation
so as to expose the three insulated wires.
3Strip 3/4" of the insulation away at the end
of each of the three wires (i,1, Neutral and
Ground). Plug the connector flfllv into place
in the trait nmting connector. Be sure the
locking robs at the sides are engaged.
3/4"
NOTE: Order Kit RAK4002(M to enable a quick I