GE AW18 Training manual

Use and
Care
& Installation Guide
Air Conditioner
Contents
Adapter Plug
3
Air Direction
5
Appliance Registration
2
Care
and
Cleaning
6
Air Filter
6
Grille & Cabinet
6
Outdoor Coil
6
Consumer Services
15
Control Settings
4,5
Electrical Requirements
3
Ener~-Saving Tips
7
Extension Cords
3
Freezing Up 4
Grounding
3
Installation Instructions
8-14
Model and Serial Numbers 2,6
Problem Solver
7
Safety Instructions
2
User Maintenance Instructions 6
Warranty
Back Cover
GE Answer
Centera
800.626.2000
Model
AW18
GE Appliances

Help us help you...
Before using your air
conditioner, read this book
carefully.
It
is
intended
to
help you operate
and
maintain your new air
conditioner properly.
Keep it handy
for
answers
to
your
questions.
If
you don’t understand something
or
need
more help, write (include
your phone number):
Consumer Affairs
GE Appliances
Appliance Park
Louisville, KY 40225
Write down the mode
serial numbers. and
You’ll find them on
a
label behind
the
front
grille on the left-hand
side
of
the air discharge duct.
These numbers
are
also
on the
Consumer Product Ownership
Registration
Card
that
ca[ne
with
your
air
conditioner. Before
sending in this card, please write
these numbers here:
Model Number
Serial Number
Use
these
numbers in
any
correspondence or service calls
concerning your
air
conditioner.
If you received a damaged
air conditioner...
immediately contact the dealer (or
builder) that sold you the
tiir
conditioner.
Save time and money.
Before you request service...
Check the Problem Solver
section of this
&uide.
It
lists causes
of minor operating problems that
you can correct yourself.
2
WPORTANT
SAFETY
~STRUCTIONS
Read all instructions before
using this appliance.
When
using this appliance, always
exercise basic safety precautions,
including the following:
●
Use this
appliance
only for its
intended purpose
as described
in this
Use
and Care Guide.
●
This air conditioner must be
properly installed in accordance
with the Instillation Instructions
before it is used. See
grounding
instructions.
●
Never unplug your air
conditioner by pulling on the
power cord.
Always grip plug
firmly and
pull
straight out from
the receptacle.
●
Repair or replace immediately
all electric service cords that
have become frayed or otherwise
damaged.
Do not use a cord that
shows cracks or abrasion damage
along its length or at either the
plug or connector end.
●
Unplug your air conditioner
before making any repairs.
Note: We strongly recommend
that any servicing be performed
by a qualified individual.
●
For your safety..
.do
not store
or use combustible materials,
gasoline or other flammable
vapors or liquids in the vicinity of
this or any other appliance.
SAVE THESE
~STRUCTIONS
H
you need
sertice
To obtain service, see the
Consumer Services page in the
back of this book.
We’
re
proud
of
our service
and
want you to be pleased.
If
for some
reason you
are
not happy with the
service you receive, here
are
three
steps to follow for further help.
FIRST, contact the people who
serviced your appliance. Explain
why you
are
not pleased. In most
cases, this will solve the problem.
NEXT, if you are still not pleased,
write
all
the details—including
your phone number—to:
Manager, Consumer Relations
GE Appliances
Appliance Park
Louisville, KY 40225
FINALLY, if your problem is still
not resolved, write:
Major Appliance Consumer
Action Panel
20 North
Wacker
Drive
Chicago, IL 60606

Electrical
Safety—MPORTANT...pleaSe
Read
Carefully.
How to connect
that mates respectively with a
230/208-volt perpendicular,
electricity
tandem
or
lar&e
tandem type wall
outlet. These types of outlets
are
For personal safety,
available at most hardware stores,
this appliance must be
properly grounded.
Electrical requirements
115-volt models
require a
115/120-
volt
a.c.,
60
hz
grounded outlet
protected with a 15 amp time
delay
fuse or circuit breaker.
The power cord on these models has
a three-prong (grounding)
plug
that
mates with a
standwd
three-prong
(grounding) wall outlet (Fig.
1)
to
minimize the possibility of electric
shock hazard from these appliances.
PREFERRED ,
METHOD
b
Q*
.3
Y,
INSURE PROPER
GROUND EXISTS
Fig. 1 BEFORE USE
Where a standard
two-prong
wall
outlet is encountered, it is your
personal responsibility and
obligation to have it replaced with
a properly grounded three-prong
wall outlet.
DO NOT, UNDER ANY
CIRCUMSTANCES, CUT
OR REMOVE THE THIRD
(GROUND) PRONG FROM
THE POWER CORD.
230/208-volt models
reuuire
their
,
own single branch circuit supplying
230/208-volt
a.c.,
protected with a
time delay fuse or circuit breaker.
This is recommended
for
best
performance and to prevent
overloading house wiring circuits,
which could
cause
a possible fire
hazard
from
overheating wires.
The power cord on these models
has
;i
230/208-volt perpendicular,
tandem or large tandem type plug
*UT
0
B,@
Q
1-
●
MATCHING
PERPENDICULAR TYPE WALL OUTLET
LINE CORD PLUG
REQUIRES 20 AMP TIME DELAY FUSE
OR CIRCUIT BREAKER PROTECTION
go
230/208-VOLT
MATCHING
TANDEM TYPE WALL OUTLET
LINE CORD PLUG
REQUIRES 15 AMP TIME DELAY FUSE
OR CIRCUIT BREAKER PROTECTION
go
0-0
0
mm
●
230/208-VOLT
MATCHING
WRGETANDEM
TYPE WALL OUTLET
LINE CORD PLUG
REQUIRES 30 AMP TIME
DELAY
FUSE
OR CIRCUIT BREAKER PROTECTION
Whether your air conditioner is
a 115-volt or a 230/208-volt unit,
TEMPORARYMETHOD
(ADAPTER PLUGS NOT
PERMITTED IN CANADA
~
The larger slot in the adapter must
be aligned with the larger slot in the
wall
outlet
to provide proper polarity
in the connection of the power cord.
CAUTION: Attaching the adapter
ground terminal to wall
outlet
cover screw does not ground the
appliance unless cover screw is
metal,
and not insulated, and
wall
outlet is grounded through house
wiring.
YOLI
should have the circuit
checked by a qualified electrician
to make sure the outlet is properly
grounded.
When disconnecting the power
cord from the adapter, always
hold
the adapter with one hand.
If
this is not done, the adapter ground
terminal is very
likely
to break
with repeated use.
Should the adapter ground
terminal break, DO NOT USE
the appliance
until
a proper
ground has again been
established.
it is important to have the wall
outlet and circuit checked by a
Use of extension cords
qualified electrician if there is
any doubt as to whether a
Because
of
potential safety hazards
proper ground exists.
under certain conditions, we
strongly recommend against the
Use of adapter plug
use of an extension cord.
However, if you
still
elect to use an
(115-volt models
onlv)
extension cord. it is absolutely
Because
of
potential safety hazards
under certain conditions, we
strongly recommend against use
of an adapter plug. However, if
you still elect to use
an
adapter,
where
local
codes permit, a
TEMPORARY CONNECTION
may be made to
a
properly grounded
two-prong
wall
outlet
by use
of
a
UL
listed adapter
(Fig.
2) available at
most
local
hardware stores.
necessary that
it
be a
UL
listed
3-
wire grounding type appliance
extension cord and that the current
carrying
rating of the cord in
amperes be equal to or greater
than
the branch circuit size shown on
the rating nameplate
of
the
appliance.

Operating Your Air Conditioner Controls
HI FAN
LO FAN LO COOL
+
+
OFF
■
&
\
9
HI COOL
SELECTOR
Selector Switch
OFF turns air conditioner off.
LO FAN provides low fan speed
operation without cooling.
HI FAN provides high fan speed
operation without cooling.
LO COOL provides cooling with
low fan speed operation.
HI COOL provides cooling with
high
fan
speed operation.
COOLER
b
4
5
2
1
THERMOSTAT
Thermostat Control
When you move the Thermostat
Control to the desired setting,
the thermostat will automatically
control the temperature of the
indoor air. The higher the number
selected, the cooler the indoor air
will become.
-
OPEN VENT CLOSE
(ON THE LOWER RIGHT
SIDE
OF THE DISCHARGE GRILLE)
Ventilation Control
When you move the Ventilation
Control to CLOSE, the vent door
is closed and only the air inside
the room will be circulated and
conditioned. Moving the control
to OPEN opens the vent door,
allowing a small amount of indoor
air to be exhausted from the room.
However, cooling effectiveness is
reduced when this control is set at
OPEN, so we suggest you don’t
keep it there long—especially in
hot, humid weather.
Freezing up
Outside
a;r
temperature
dropping
If you notice that your air
conditioner is not cooling as it
should, it may be that ice has formed
on the cooling coils. The ice blocks
air flow and stops the unit from
cooling the room. This “freezing up”
is a temporary condition that most
often occurs at night when the
Thermostat is set at a higher number
and the Selector is set on LO COOL.
To correct the condition, set the
Selector at HI FAN or HI COOL
and move the Thermostat to the
warmest setting.
A

For normal cooling
1. Set the Selector Switch at HI
COOL.
2. Set the Thermostat Control
at
the desired number (usually 4-6 is
a
good starting position). If room
temperature is not satisfactory
after a reasonable time, set the
Thermostat Control at a higher
number for a cooler room or at a
lower number for a warmer room.
3. Set the Ventilation Control at
CLOSE except for brief periods
when you want to exhaust room air
to the outside.
For maximum cooling
1. Set the Selector Switch at
HI COOL.
2. Turn the Thermostat Control
to
8.
3. Set the Ventilation Control at
CLOSE.
For quieter operation
1. Set the Selector Switch
at
the
LO COOL position.
2. Turn the Thermostat Control to
the desired number.
3. Set the Ventilation Control at
CLOSE.
For nighttime operation
During the cooler evening hours,
we recommend that you set the
Selector Switch at LO COOL
for quieter operation and the
Thermostat Control at mid-range
(4 or 5). Set the Ventilation Control
at CLOSE.
For extreme temperatures
For greatest economy and best
performance, we suggest you set
the Selector Switch at HI COOL in
extremely hot weather.
To adjust air direction
Up and down
The up-and-down air direction
louvers are controlled by tabs
thal
let you position the louvers to
discharge the air up, down or
straight out.
Side to Side
I
CIRCUUIRE
OFF
m
I
111111]
ON
For fixed side-to-side air
direction, set the
Circulaire
Switc
to ON until the desired air directio
is obtained, then move it to OFF.
For continuous side-to-side air
circulation,
set the Circulaire
Switch to ON and leave it there.

Care and Cleating
USER MAINTENANCE
INSTRUCTIONS
Turn
air
conditioner off and
remove the plug from the wall
outlet before cleaning.
Grille & Cabinet
Wipe
front
grille with
a
clean
cloth
lightly dampened with mild liquid
dishwashing detergent. Wash
cabinet with mild
soap
or detergent
and lukewarm
water.
Outdoor Coil
This coil on the outdoor side
of
the unit should be checked
periodically and cleaned if
clogged with dirt
or
soot from
the atmosphere.
If
extremely
soiled, it may need to be steam
cleaned,
a
service available
through your GE service outlet.
Front Grille
Remove the front grille if you
need to read the model and
serial numbers.
To remove the grille:
1. Remove
air
filter
from
the grille
by sliding it to the right.
2. Remove and save the screw that
holds the
grille
to the chassis.
3. Press inward on the lower right
side of the cabinet until the tab is
clear
of the slot
and
allow the
grille to come toward you slightly.
4. Repeat this process for the lower
left side.
Do
not
pull the bottom
edge
toward you more than 3 inches or
damage to the top 2 tabs of the
grille may occur.
5. Grasp the grille’s lower right
and
left
corner and carefully lift
straight upward
to
disengage the
2 top tabs from their
slots
in the
cabinet front edge.
CABINET
:
“o
SCREW
To attach the grille:
The grille is attached on the
front
of
the cabinet by
four
tabs and a screw.
1. Remove air filter from the
grille
by sliding it to the right.
2.
Engage two tabs on the grille’s
top inside edge with two
slots
in
the cabinet front edge.
3. Press inward on the lower right
side of the
metal
cabinet at the
location of the slots and then
carefully push the grille in
until
the
tab engages with the
slot.
Do not strike or forcibly hit the
plastic grille or damage to the
tabs will occur.
4. Repeat this process for the lower
left side.
5. Mount the grille on the front of
the cabinet with the screw attached
to the grille during shipping, and
slide the filter back into place.
Air Filter
The air filter behind the
inlet
grille
should be washed at least every
30
days or as often as it needs cleaning.
To remove the filter,
Grasp the tab
on the filter and pull to the right.
Vacuum the filter on the dusty side
to remove light dust. Wash the
filter, cleaner side up, under gently
flowing water to wash out
accumulated dust and lint. If the
filter is very dirty, use a mild
household detergent in the wash
water. Let the filter dry thoroughly
before replacing it.
When replacing the filter,
be sure
the word FRONT is facing you as
you slide the filter back into place.
6

Energ-Saving
Tips
● Keep
the
air
filter
clean.
●
For
most efficient cooling,
keep the Ventilation Control in
the CLOSE position except when
you want to exhaust air, smoke or
odors from the room.
● Don t
let
the room
get
too
hot. Whenever possible, turn the
unit on
before
the room heats up.
When heat is “stored up” in walls,
furniture, rugs
and
draperies, your
air
conditioner
takes
longer to
produce the desired comfort
condition.
● Keep windows
and
doors
closed. Cool, dry
air
escapes
when they’re open.
● Keep furnace tloor registers
and
cold
air
returns closed. Cold
air
can
easily
escape
through them.
●
Don’t let
drapes
or furniture block
the top or front
of
unit
and
restrict
air
flow when it is operating.
●
It’s best to operate your
air
conditioner
at
high
speed during
extremely hot weather.
●
Keep the outdoor condenser
coil clean.
●
Turn
air
conditioner off before
vacations or extended absences
from home.
<~-:
Questions
~;
Use This Problem Solver
~
-
PROBLEM
AIR CONDITIONER
DOES NOT OPERATE
AIR CONDITIONER
“DOES NOT COOL
AS IT SHOULD”
OPERAT NC
SOUNDS
WATER DRIPPING
OUTSIDE
WATER DRIPPING
INSIDE
WATER IN BASE PAN
(ON OUTDOOR SIDE)
POSSIBLE CAUSE
● Not plugged in. Plug may have been bumped
loose by vacuum cleaner or furniture.
● If plugged in, fuse could have blown or
circuit breaker may have tripped.
●
Curtain, blinds or furniture blocking the top or
the front of the air conditioner will restrict air
flow.
● Thermostat Control
may
not be set high
enough. Move the knob to a higher number.
Highest setting should provide maximum
cooling.
● Air filter dirty, should be cleaned at
least
every
30
days.
●
Room may have been very hot when air
conditioner was first turned on. Allow time
for it to cool down.
●
Cold air may be escaping through open
furnace floor registers and cold air returns.
● Ventilation Control may be set at OPEN
position, allowing hot outside air to enter the
room.
● Cooling coils have iced up. To melt
ice,
move
the Selector Switch to HI FAN and the
Thermostat Control to a lower number.
● Thermostat click, a metallic sound, may be
heard when compressor cycles on and off. This
is normal.
● Fan runs continuously when Selector
Switch is in COOL or FAN position.
This is normal.
● Excess water may
oveflow
in extremely hot
and humid weather. This is normal.
●
Air conditioner must be installed level or tilted
slightly to the outside for proper water disposal.
● This is normal for a short period in areas with
little humidity; normal for a longer period in
very humid areas. Moisture removed from
indoor air drains to rear of cabinet where it is
picked up by a fan and thrown against the
outdoor condenser coil.
If you need more help... call,
toll
free:
GE
Answer
Center’”
800.626.2000
consumer information service
7

BEFORE YOU
BEG/fl
Read these instructions completely and
carefully.
IMPORTANT–Observe all governing codes
and ordinances.
lNSTALLER—Be
sure to leave these
instructions with the consumer.
CONSUMER–Keep these instructions for
future reference.
ELECTRICAL REQUIREMENTS
FOR PERSONAL SAFETY:
●
THIS APPLIANCE MUST BE PROPERLY
GROUNDED. See grounding instructions.
● DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVE THE THIRD GROUNDING
PRONG FROM THE POWER CORD.
● WE RECOMMEND THAT YOU DO NOT USE
AN EXTENSION CORD OR AN ADAPTER
PLUG WITH THIS APPLIANCE.
● DO NOT CHANGE THE PLUG ON THE
POWER CORD OF THIS APPLIANCE.
● FOLLOW NATIONAL ELECTRICAL CODES
OR LOCAL CODES AND ORDINANCES.
115V 230V/208V 230V/208V 230V/208V
15 AMP circujt 20 AMP
circunt
15 AMP circuit 30 AMP circuit
“parallel” type “perpendicular” type “tandem” type “tandem” type
@@@@
● If the electrical supply provided does not meet
the above specifications, call a licensed electrician.
● Aluminum house wiring may pose special
problems—consult a qualified electrician.
● This unit requires a separate circuit serving only
this appliance.
WINDOW REQUIREMENTS
● Standard double-hung window with actual
opening width of 29” to 46”.
● Clear vertical opening of 18“ minimum from
bottom of sash to stool.
● Install the air conditioner in a window where
there will be enough clearance around the cabinet
to allow ample circulation of air through the unit.
//’
I
I
t
2g”
tO
46”
w
.
18“
min.
1
J
Note:
All
supporting parts should be secured to
firm wood, masonry or metal.
8

WINDOW INSTALLATION
TOOLS NEEDED
● Phillips head screwdriver
● Blade-type screwdriver
● Sharp knife or razor blade
● Rule or tape measure
● Pencil ● Level ● Box wrench
SCREWS FURNISHED (see samples)
Type A
Type
B
Type C Type D Type E Type F
Qty-7 Qty-3 Qty-8 Qty-3 Qty-2 Qty-4
Type A
screw
\
Type A
screw support
iller
Type A
w
(right)
screw
(continued next page)
9

WINDOW INSTALLATION
(cont,””e~,
❑
REMOVEFRONTGRllLE
See Front Grille section.
❑
PREPARE CHASSIS.
1. Remove chassis locking bracket and chassis
locking screw with a Phillips head screwdriver.
(Save for reuse.)
Y
\
Chassis locking screw
Chassis locking bracket
2. Remove ground screw and ground wire. (Save
for reuse.)
Ground
wire
3. Remove chassis from cabinet using the base pan
as a handle.
❑
PREPARE CABINET
+
-
Top mounting rail
Room side
+
~
\Cablnettop
Type D screw
1. Install top mounting rail onto top of cabinet with
3 Type D screws.
Ill
II
Type B screw Type B
o
screw
\
2. Install bottom sill channel onto cabinet by
inserting notches on channel into slots located on
bottom of cabinet and securing with 3 Type B
screws.
10

wA~ACH
WINDOWFILLER
PANELS.
1. Sl;de left window f;ller panel ;nto top and bottom
mounting rails.
2. Slide retainer panel into window filler panel and
attach to cabinet with 2 Type F screws.
3,
Repeat for right side.
Window —
filler panel
0
I
c
o
Y
Top mounting rail
Bottom mounting rail
— Retainer panel
❑
lNS~LL
CABINETIN WINDOM
1. Cut sealing ribbon to window width and stick it
to bottom of the lower window sash.
2. Measure and mark center of window sill to
establish mounting position of cabinet.
3. Install cabinet into opening and center on line
marked on window sill. Put top of cabinet toward
you and lower window sash behind top mounting
rail.
Center line
– Sealing
ribbon
(ADHESIVE
SIDE)
4. Extend and secure left and right window filler
panels to window sash with Type A screws, one on
each side.
5. Secure top mounting rail with two Type E screws.
Ier
❑
INSMLL
SUPPORTBRACKETS.
1. Install large adjusting bolts into the support
brackets.
2. Select matching pair of holes on bottom flange
of cabinet, just past the outer edge of sill. Attach left
and right support brackets to bottom flange of
cabinet with 2 Type C screws, ensuring that
locations match.
—--
—..—
-. —--
—..—
Match holes for
bracket support
3. Level cabinet
by rotating the
/
Window
adjusting bolt.
Cabinet should
be level or have a
1/8” pitch toward
the outside.
4. Attach a 90°
bracket on each
T
;
‘
;:;:;:
side of the bottom
Wood
of the cabinet with
Q
Sealing
ribbon
.
Cabinet Outdoor
~y
v?
II
screw
\
Type C screws to
Wall
Adjustable bolts
secure the cabinet position in the window. If the
window frame is wood, fasten the lower part of the
brackets to the frame with Type A screws.
(continued next page)
11

WINDOW INSTALLATION (Continued)
❑
lNSMLL SASH
GASKEZ
Cut foam sash gasket to window width and stuff
between top of lower sash and glass panes of
upper sash. Make sure foam gasket is flush with
top of lower sash.
❑
lNS~LL
SASH LOCK
Install sash locking bracket using Type A screws.
Type A
screw
~
INSULL
CHASSIS IN CABINED
1. Slide chassis into cabinet. (Make sure tubing on
unit is not touching wall case. )
2. Lock chassis into cabinet by reinstalling chassis
locking bracket and chassis locking screw removed
in Step 2.
Chassis locking bracket
3. Reconnect ground wire removed in Step 2 to
chassis.
4. Remove enough line cord to reach the wall
receptacle.
❑
CHECKFORAIR
LEAKS.
I
Seal small openings around cabinet with gum-type
sealer, provided.
I
❑
INSMLL
FRONTGRILLE
See Front Grille section.
12

I
THROUGH-THE-WALL INSTALLATION
THE CABINET MAY BE INSTALLED
THROUGH THE WALL IN BOTH EXISTING
BUILDINGS AND NEW CONSTRUCTION.
IMPORTANT
●
Any side louvers must project on
the
oudoor
side of the wall.
● The room side of the cabinet must project into
the room at least 1“ from the finished wall.
● The cabinet must be installed level from side to
side and with a 3/8” tilt from front to rear.
TOOLS REOU/RED
●
●
●
●
✎
●
✎
Phillips head screwdriver
Blade-type screwdriver
Magnetic stud finder (optional)
Tin snips
Handsaw ● Hammer
Level ● Caulking gun
Chisel ● Tape measure
Concrete saw (if installing through a masonry
I
●
wall)
ADDITIONAL
MATERIAISIEEDED
(obtain locally)
● 12 #10 wood screws, 1“ long
● 1 tube high grade caulking compound
● Wooden framing studs
● Lintel, if required, to support bricks or blocks
above opening
● Flashing, alum inure or galvanized steel
❑
PREPARE
WA[l
OPENING.
1.
Determine size of opening.
Measure width and
height of cabinet and add 1/8” to each dimension.
2.
Choose the
wall opening location.
Be sure a
power receptacle is (or will be) installed nearby.
3. Make the opening. Frame it to support the
weight of the air conditioner.
Add metal flashing over bottom of frame opening
and 1“ up on sides to reduce the possibility of
moisture entering the area between the inner and
outer wall. The flashing lip should be 1“ wide and
bent down
45:
See the illustration, page 14.
❑
PREPARE THE CABINED
1. Remove chassis from cabinet. See
W;ndow
Installation, Step 2.
2. With caulking compound or electrical tape, seal
all holes provided in the cabinet for window
installation hardware not used in this installation.
❑
/NS~LL
CABINETIN WALL.
1.
Place cabinet in wall opening.
2. Secure cabinet bottom rail to wooden frame
with two 1“ long #10 wood screws.
.=:
>::=
-.
<.Z
.-
-<:=
>
,...
=
>=
.:.=-
-~
.*
~,>:
+
:*
+~q
*
+
v
-<
(continued next page)
13

❑
INSMLL CABINETIN WALL
(continued)
3. Secure cabinet sides to wooden frame with six
1“ long #10 wood screws and secure cabinet top
to frame with four 1“ long #10 wood screws.
Drill holes in cabinet sides and top, if necessary for
proper installation. If frame is oversize, use shims to
prevent cabinet distortion.
4. Caulk all four sides on the outdoor side of
cabinet to prevent moisture from getting
through to the interior wall. Use of flashing (a
piece of aluminum or galvanized steel available at
most hardware stores) will further prevent moisture
from getting into interior walls.
5. Install wood trim molding (obtained locally)
around roomside projection of cabinet, if desired.
1
~
SLIDE CHASSIS INTO CABINEZ
Lift the chassis and carefully slide it into cabinet. Do
not push on controls or finned coils. Make sure
chassis is firmly seated toward rear of cabinet.
❑
lNS~LL
CHASSIS IN CABINED
See Step 9 of Window Installation.
I
❑
lNS~LL
FILTER AND GRILLE
See Care and Cleanlng page.
ster
Line
Trim
Molding
(if desired)
——
——
\
I
==Flashing,
j
,
~l~s~ingJ--:::’”’
k-
1
—..
.
11
Ill
I
J
min.
INSIDE
14

Wdll
Be There
With the purchase of your new GE appliance, receive the
assurance that if you ever need information or assistance
from GE,
wdll
be there. All you have
to
do is call–toll-free!
GEAnswer
Center@
80~6262000
In-Home Repair
Service Contracts
Service
80MEXARES
(80M32-273~
A
(;E1
consllnlet-
serlrice
rrt)fkssi(}niil
will
rrovide
expert
rep:tir
selvice,
schedLIled
itl
ii
time
th:~t
convenient
for”
yoLI.
Many
(;E
(;onsunler
Service
(()]rlp;~~ly-()reratecl locations”
offer
you service> today
or
(ornor-row,”
or
at
your
convenience
(7:()()
;~.m.
to
7:()()
r.nl.
()()()
~,~n.
LO
2:()()
J>.
rn.
S:itur-
weekdiiys,
. .
d:iys).
Our
f>{c(oq-t12iitlecl
technicians
know
yoLrr
iipJ~liLmce
inside
~uld
oLlt-
SC) most repairs c:ul he
h~mdled
in,j~]s[
one visit.
80&626-2224
Wh:l[t’veryol]t
qtl~s[ion
:]1}0111
;tr]y
(;
Ill:tjot-;{rrli;in(e,
(;kl Answet(:enlet-’
inf;
)rrn2Ltion
scrvicc
isi~vitil:lhlc
10
heir. Yotlr-c:ill-itnd ?()(lr([Llesli()ll-
will he iinswered
rtomptly
:ind
coLrr’leoLlsly.”
Arid
J’OLl
can
Cidl
iiny
titne.
(; F; Arrswer(:etltet-’”
sc[l’ice
is
OJ)en
24
ho
Llt”S
il
[l:[y,
7
(t;ivs
ii
week.
YC)LI
can
h:lve
the
secLu-e
fkcling
th~it
(;E
(;{)nsurner Service will still be
there
:tf’ter
your
w;irranty
exJ}ires.
I)ur-
ch:tse:{
CZE
contrilct while your
w2tr-
r:lrrty
is
slill
in eflkct
iirrd
)()(1’11
receive
<1
sLll)stan[.i;~l
clisco
Lint. With
;L
nlultiple-
yeilr
corllr:ict,
yell’r-
c
>
:issllrcd
of
future
service
at
tod:ly’s prices.
Telecommunication
Detice for the Deaf
Parts
andAccessories
Individuds
qudfied
to service their
o-
appliances
c:m
h:{ve needed
p:u-ts
or-
:~ccessor-ics
sent
dir-cctly
to
their home, free
of
shipping ch:uge!
‘rhe
(;E
r:rrls system pro~ides :lccess
to over
47,()()()
r:~rts...z~nd
all
(1E
(;enuine
Renewal Paris
~tre
fully
warrzurtecf.
VISA, Master-(;ard and
Discover cards are acceJ]ted.
User
maintenance instructions
contained in this booklet cover proce-
dures intended to be performed by
any user. Other servicing
generdy
shodd
be referred to
qufified
ser-
vice personnel. Caution must be
exercised, since improper servicing
may
cause
unsafe operation.
,ECTIONA.A
...,..
..,
!..,”
..,..,
”,7.
”..”
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.=..,
,..
kr
Customers With
Special Needs...
80~6262000
Uron
reqLlesl,
(;klwill
rro~ride
Br:iillc’
corrltolsfot
- ;lv:irie[yof’(
;k:2iJ>Jlli2illcc’s,
;Irrd;iht’(
)cll
Llt’t’
toilssist
irr
p12ulnin,4y
ii
h:u-t-ier-fret
ki{chenfi)rrersons
with
lir]li(e{l
rll<)l)ilit?.
T()()l)tilirl these
itenrs,
fiec’of’ch:~rge,(:~ll
800.62(i.2000.
(;orlsLlnlerswitll imp;lired
he~tring
ot”SJ)eCChW
h{)
t12iVC21CCCSS
{();tTDI)
ol.iicc)rlvetlt.i~)rl;il
Lelet.ypcwriler
m:l}’
(::ill
800-TIJD-(;W(:”
(800 -8:33-4:322j”
10
reqL]est
infi)rrn:ltion or service.
.
.
a

YOUR GE ROOM AIR CONDITIONER
WARRANTY
Save proof of original purchase date such as your sales slip or
cancelled
check to establish warranty period.
WHAT IS COVERED
FULL ONE-YEAR WARRANTY
For one year from date of original
purchase, we will provide, free of
charge, parts and service labor in
your home to repair or replace
any part of the room air
conditioner that fails because
of a manufacturing defect.
FULL-FIVE
YEAR WARRANTY
For five years from the date of
original purchase, we will provide,
free of charge, parts and service
labor in your home to repair or
replace any part of the sealed
refrigerating system (the
compressor, condenser,
evaporator and all connecting
tubing) that fails because of a
manufacturing defect.
For each of the above warranties:
Transportation expense to and from
a service shop and shop service
labor if required will be free of
charge.
This warranty is extended to
the original purchaser and any
succeeding owner for products
purchased for use in the 48
mainland states, Hawaii and
Washington, D.C. In Alaska the
warranty is the same except that it
is LIMITED because you must pay
to ship the product to the service
shop or for the service technician’s
travel costs to your home.
All warranty service will be
provided by our Factory Service
Centers or by our authorized
Customer Care” servicers during
normal working hours.
Look in the White or Yellow Pages
of your telephone directory for
GENERAL ELECTRIC
COMPANY, GENERAL
ELECTRIC FACTORY SERVICE,
GENERAL ELECTRIC-HOTPOINT
FACTORY SERVICE or GENERAL
ELECTRIC CUSTOMER CARE(”)
WHAT IS NOT COVERED
● Service trips to your home to
teach you how to use the product.
Read your Use and Care material.
If you then have any questions
about operating the product please
contact your dealer or our
Consumer Affairs office at the
address below, or call, toll free:
GE Answer Center(’)
800.626.2000
consumer information semice
● Improper installation.
If you have an installation
problem, or if the air conditioner is
of improper cooling capacity for the
intended use, contact your dealer
or installer. You are responsible for
providing adequate electrical
connecting facilities.
● Replacement of house fuses or
resetting of circuit breakers.
Q
I n commercial locations labor
necessary to move the unit to a
location where it is accessible for
service by an individual technician.
● Failure of the product resulting
from modifications to the product or
due to unreasonable use including
failure to provide reasonable and
necessary maintenance.
. Failure due to corrosion on
models not corrosion-protected,
● Damage to product caused
by improper power supply voltage,
accident, fire, floods or acts of God.
WARRANTOR IS NOT
RESPONSIBLE FOR
CONSEQUENTIAL DAMAGES.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion
may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which
vay
from state to state.
To know what your legal rights are in your state, consult your local or state consumer affairs office or your state’s Attorney General.
Warrantor:GeneralElectricCompany
If further help is needed concerning this warranty, write:
Manager—Consumer Affairs, GE Appliances, Louisville, KY 40225
I
I pub
No.
49-7265
I
.
.
.
.
.
I
I
AMV1
11-91
CG
Table of contents
Other GE Air Conditioner manuals

GE
GE Appliances AEE18 Operating instructions

GE
GE AEW10A Operating instructions

GE
GE Zoneline AZ28E15DA User manual

GE
GE AHE12 Series Original instructions

GE
GE AEM24DQ Original instructions

GE
GE AEM12 Series Operating instructions

GE
GE Zoneline AZ29E07DAC Manual

GE
GE AED25DN Assembly instructions

GE
GE AKM18DN User instructions

GE
GE ENERGY STAR AEM08LN Manual
Popular Air Conditioner manuals by other brands

LG
LG UM30F installation manual

Trane
Trane Duplex Water-Cooled Hermetic CenTraVac Installation

Carrier
Carrier 38QUS014DS2 series installation manual

HEIL
HEIL FEM4X installation instructions

Keith Products
Keith Products TR-134 System service manual

Mitsubishi Electric
Mitsubishi Electric City Multi PCFY-P15NGMU-E Technical & service manual