GE DCVH680EJWW User manual

WARNING RISK OF FIRE
7RUHGXFHWKHULVNRIVHYHUHLQMXU\RUGHDWKIROORZDOOLQVWDOODWLRQ
LQVWUXFWLRQV
&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HG
LQVWDOOHU
,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHVHLQVWUXFWLRQVDQGLQ
DFFRUGDQFHZLWKORFDOFRGHV
7KLVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\ULJLGPHWDOµGLDPHWHUGXFWZRUNLQVLGHWKHGU\HUFDELQHW
DQGXVHRQO\8/DSSURYHGWUDQVLWLRQGXFWLQJEHWZHHQWKHGU\HUDQG
WKHKRPHGXFW
'2127LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJ
PDWHULDOV,IÀH[LEOHPHWDOVHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHG
LWPXVWEH8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFHZLWKWKH
LQVWUXFWLRQVIRXQGLQ´&RQQHFWLQJ7KH'U\HU7R+RXVH9HQWµRQ
SDJHVRIWKLVPDQXDO)OH[LEOHYHQWLQJPDWHULDOVDUHNQRZQ
WRFROODSVHEHHDVLO\FUXVKHGDQGWUDSOLQW7KHVHFRQGLWLRQVZLOO
REVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLWFRXOG
EHH[SRVHGWRZDWHUDQGRUZHDWKHU
6DYHWKHVHLQVWUXFWLRQV,QVWDOOHUV%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
NOTE: Installation and service of this dryer requires basic
mechanical and electrical skills. It is your responsibility
to contact a quali¿ed installer to make the electrical
connections.
Installation
Instructions
Electric Dryer
01
Questions on Installation? Call: 800.GE.CARES (US)
RUYLVLWRXUZHEVLWHDWwww.GEAppliances.com (US)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT-6DYHWKHVHLQVWUXFWLRQVIRUORFDO
LQVSHFWRU·VXVH
IMPORTANT-2EVHUYHDOOJRYHUQLQJFRGHV
DQGRUGLQDQFHV
Note to Installer -%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
Note to Customer -.HHSWKHVHLQVWUXFWLRQVZLWK
\RXU2ZQHU·V0DQXDOIRUIXWXUHUHIHUHQFH
%HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRU
GLVFDUGHGUHPRYHWKHGU\HUGRRU
6HUYLFHLQIRUPDWLRQDQGWKHZLULQJGLDJUDPDUH
ORFDWHGLQWKHFRQWUROFRQVROH
'RQRWDOORZFKLOGUHQRQRULQWKHDSSOLDQFH&ORVH
VXSHUYLVLRQRIFKLOGUHQLVQHFHVVDU\ZKHQWKH
DSSOLDQFHLVXVHGQHDUFKLOGUHQ
,QVWDOOWKHGU\HUZKHUHWKHWHPSHUDWXUHLVDERYH
)IRUVDWLVIDFWRU\RSHUDWLRQRIWKHGU\HUFRQWURO
V\VWHP
3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRW
FRYHUHGXQGHUWKH:DUUDQW\
TOOLS YOU
WILL NEED
PHILLIPS SCREWDRIVER
SLIP JOINT PLIERS
LEVEL
FLAT BLADE SCREWDRIVER
MATERIALS YOU WILL NEED
GLOVES
SAFETY
GLASSES
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
3/4" STRAIN
RELIEF
UL RECOGNIZED
4" DIA. METAL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT (IF NEEDED.)
DUCT TAPE
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.
4” COVER PLATE (IF NEEDED
(KIT WE1M454)
234D1582P001 31-16680 03-12 GE
6WHS 3UHSDUHWKHDUHDDQGH[KDXVWIRULQVWDOODWLRQRIQHZGU\HU
VHHVHFWLRQ
6WHS &KHFNDQGHQVXUHWKHH[LVWLQJH[WHUQDOH[KDXVWLVFOHDQVHH
VHFWLRQDQGPHHWVDWWDFKHGLQVWDOODWLRQVSHFL¿FDWLRQVVHH
VHFWLRQ
6WHS 5HPRYHWKHIRDPVKLSSLQJSDGVVHHVHFWLRQ
6WHS 0RYHWKHGU\HUWRWKHGHVLUHGORFDWLRQ
6WHS &RQQHFWWKHSRZHUVXSSO\VHHVHFWLRQ
6WHS &RQQHFWWKHH[WHUQDOH[KDXVWVHHVHFWLRQ
6WHS /HYHO\RXUGU\HUVHHVHFWLRQ
6WHS &KHFNWKHRSHUDWLRQRIWKHSRZHUVXSSO\DQGYHQWLQJ
6WHS 3ODFHWKH2ZQHU·V0DQXDODQGWKH,QVWDOODWLRQ,QVWUXFWLRQV
LQDORFDWLRQZKHUHWKH\ZLOOEHQRWLFHGE\WKHRZQHU
)RUDOFRYHRUFORVHWLQVWDOODWLRQVHHVHFWLRQ
)RUEDWKURRPRUEHGURRPLQVWDOODWLRQVHHVHFWLRQ
)RUPRELOHRUPDQXIDFWXUHGKRPHVHHVHFWLRQ
)RUJDUDJHLQVWDOODWLRQLIDOORZHGE\ORFDOFRGHVVHHVHFWLRQ
)RU)RUVLGHRUERWWRPH[KDXVWVHHVHFWLRQ
PEDESTALS FOR DRYERS
(comes with individual installation instructions)
Three models available: - SBSD107H
- SBSD137H - SBSD227F

Installation Instructions
Minimum Clearance Other Than Alcove or Closet Installation
0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVDQGLQUHDU&RQVLGHUDWLRQ
mustEHJLYHQWRSURYLGHDGHTXDWHFOHDUDQFHIRULQVWDOODWLRQDQGVHUYLFH
1PREPARING FOR INSTALLATION
OF NEW DRYER
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer exhaust.
REMOVING LINT FROM WALL EXHAUST
OPENING
Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition duct.
2
ELECTRICAL CONNECTION INFORMATION
WARNING - TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCK AND PERSONAL INJURY:
DO NOT USE AN EXTENSION CORD OR AN
ADAPTER PLUG WITH THIS APPLIANCE.
'U\HUPXVWEHHOHFWULFDOO\JURXQGHGLQDFFRUGDQFHZLWK
ORFDOFRGHVDQGRUGLQDQFHVRULQWKHDEVHQFHRIORFDO
FRGHVLQDFFRUGDQFHZLWKWKHNATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70.
CONNECTING DRYER USING 4-WIRE
CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTE: Since January 1,1996, the National Electric code requires
that the new constructions utilize a 4-wire connection to an
electric dryer.
7XUQRȺWKHFLUFXLWEUHDNHUVDPSRUUHPRYHWKH
GU\HU·VFLUFXLWIXVHDWWKHHOHFWULFDOER[
%H VXUH WKH GU\HU FRUG LV XQSOXJJHG IURP WKH ZDOO
UHFHSWDFOH
5HPRYH WKH SRZHU FRUG FRYHU ORFDWHG DW WKH ORZHU
EDFN
5HPRYH DQG GLVFDUG JURXQG VWUDS .HHS WKH JUHHQ
JURXQGVFUHZIRUVWHS
,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG
HQWU\KROH%ULQJSRZHUFRUGWKURXJKVWUDLQUHOLHI
&RQQHFWSRZHUFRUGDVIROORZV
$&RQQHFWWKHKRWOLQHVWRWKHRXWHUVFUHZVRI
WKHWHUPLQDOEORFNPDUNHG/DQG/
%&RQQHFWWKHQHXWUDOZKLWHOLQHWRWKHFHQWHURI
WKHWHUPLQDOEORFNPDUNHG1
$WWDFK JURXQG ZLUH RI SRZHU FRUG ZLWK WKH JUHHQ
JURXQGVFUHZKROHDERYHVWUDLQUHOLHIEUDFNHW7LJKWHQ
DOOWHUPLQDOEORFNVFUHZVVHFXUHO\
3URSHUO\VHFXUHSRZHUFRUGWRVWUDLQUHOLHI
5HLQVWDOOWKHFRYHU
L1
N
L2
RELOCATE GREEN
GROUND SCREW
HERE
STRAIN
RELIEF
BRACKET
GREEN OR
YELLOW WIRE
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
SCREWS
(3)
HOT
WIRE
COVER
NEUTRAL
(White)
REMOVE GROUND STRAP
AND DISCARD. KEEP GREEN
GROUND SCREW
4 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).
INTERNAL DUCT
OPENING CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
ELECTRICAL REQUIREMENTS
7KLVGU\HUPXVWEHFRQQHFWHGWRDQLQGLYLGXDOEUDQFK
FLUFXLWSURWHFWHGE\WKHUHTXLUHGWLPHGHOD\IXVHVRU
FLUFXLWEUHDNHUV$IRXURUWKUHHZLUHVLQJOHSKDVH
9RU9+]DPSFLUFXLWLVUHTXLUHG
GROUNDING INSTRUCTIONS
7KLVGU\HUPXVWEHFRQQHFWHGWRDJURXQGHGPHWDOSHUPD
QHQWZLULQJV\VWHPRUDQHTXLSPHQWJURXQGLQJFRQGXFWRU
PXVWEHUXQZLWKWKHFLUFXLWFRQGXFWRUVDQGFRQQHFWHGWR
WKHHTXLSPHQWJURXQGLQJWHUPLQDORQWKHDSSOLDQFH
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.

Installation Instructions
CONNECTING DRYER USING 3-WIRE
CONNECTION
3-wire Connection
1RWIRUXVHLQ&DQDGD
'2127XVHIRU0RELOH+RPH,QVWDOODWLRQV
127IRUXVHRQQHZFRQVWUXFWLRQ
127IRUXVHRQUHFUHDWLRQDOYHKLFOHV
127IRUXVHLQDUHDVZKHUHORFDOFRGHVSURKLELWJURXQGLQJ
WKURXJKWKHQHXWUDOFRQGXFWLRQ
7XUQ RȺ WKH FLUFXLW EUHDNHUV DPS RU UHPRYH WKH
GU\HU·VFLUFXLWIXVHDWWKHHOHFWULFDOER[
%HVXUHWKHGU\HUFRUGLVXQSOXJJHGIURPWKHZDOO
5HPRYH WKH SRZHU FRUG FRYHU ORFDWHG DW WKH ORZHU
EDFN
,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG
HQWU\KROH%ULQJSRZHUFRUGWKURXJKVWUDLQUHOLHI
&RQQHFWSRZHUFRUGDVIROORZV
$&RQQHFWWKHKRWOLQHVWRWKHRXWHUVFUHZVRIWKH
WHUPLQDOEORFNPDUNHG/DQG/
%&RQQHFWWKHQHXWUDOZKLWHOLQHWRWKHFHQWHURI
WKHWHUPLQDOEORFNPDUNHG1
%H VXUH JURXQG VWUDS LV FRQQHFWHG WR QHXWUDO FHQWHU
WHUPLQDORIEORFNDQGWRJUHHQJURXQGVFUHZRQFDELQHW
UHDU7LJKWHQDOOWHUPLQDOEORFNVFUHZVVHFXUHO\
3URSHUO\VHFXUHSRZHUFRUGWRVWUDLQUHOLHI
5HLQVWDOOWKHFRYHU
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
L1
L2
STRAIN RELIEF
BRACKET
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
HOT
WIRE
GROUND
STRAP
GREEN
GROUND
SCREW
NEUTRAL
(White)
SCREWS
(3)
IF REQUIRED, BY LOCAL CODE,
INSTALL EXTERNAL GROUND
(NOT PROVIDED) TO GROUNDED
METAL, COLD WATER PIPE, OR
OTHER ESTABLISHED GROUND
DETERMINED BY A QUALIFIED
ELECTRICIAN.
COVER
3 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH CLOSED
LOOP OR SPADE TERMINALS WITH
UPTURNED ENDS (NOT SUPPLIED).
3EXHAUST INFORMATION
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\RI
ELUGVRURWKHUZLOGOLIH
7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWR
WKHH[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQR
PDLQWHQDQFHWRSUHYHQWFORJJLQJ
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
FRXOGFDXVHOLQWEXLOGXS
:DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQGOHYHO
RUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHGGRZQ
SEPARATION OF TURNS
)RUEHVWSHUIRUPDQFHVHSDUDWHDOOWXUQVE\DWOHDVWIW
RIVWUDLJKWGXFWLQFOXGLQJGLVWDQFHEHWZHHQODVWWXUQDQG
H[KDXVWKRRG
TURNS OTHER THAN 90º
2QHWXUQRIRUOHVVPD\EHLJQRUHG
7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ
(DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ
WARNING - IN CANADA AND IN THE
UNITED STATES, THE REQUIRED EXHAUST
DUCT DIAMETER IS 4 in (102mm). DO NOT USE
DUCT LONGER THAN SPECIFIED IN THE EX-
HAUST LENGTH TABLE.
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
,QFUHDVHWKHGU\LQJWLPHVDQGWKHHQHUJ\FRVW
5HGXFHWKHGU\HUOLIH
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
The correct exhaust installation is YOUR
RESPONSIBILITY. Problems due to incorrect installation
are not covered by the warranty.
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO
WUDQVLWLRQGXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW
7KHMAXIMUM ALLOWABLEGXFWOHQJWKDQGQXPEHURI
EHQGVRIWKHH[KDXVWV\VWHPGHSHQGVXSRQWKHW\SHRI
GXFWQXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRGZDOO
FDSDQGDOOFRQGLWLRQVQRWHGEHORZ7KHPD[LPXPGXFW
OHQJWKIRUULJLGPHWDOGXFWLVVKRZQLQWKHWDEOHEHORZ
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90°
Elbows Rigid
Metal Rigid
Metal
90 Feet
60 Feet
45 Feet
35 Feet
25 Feet
60 Feet
45 Feet
35 Feet
25 Feet
15 Feet
0
1
2
3
4
Use only for short
run installations
EXHAUST LENGTH

Installation Instructions
SEALING OF JOINTS
$OOMRLQWVVKRXOGEHWLJKWWRDYRLGOHDNV7KHPDOHHQGRI
HDFKVHFWLRQRIGXFWPXVWSRLQWDZD\IURPWKHGU\HU
7KHGXFWVKDOOQRWEHDVVHPEOHGZLWKVFUHZVRURWKHU
IDVWHQLQJPHDQVWKDWH[WHQGLQWRWKHGXFWDQGFDWFKOLQW
'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\
ZUDSSLQJWKHRYHUODSSHGMRLQWVZLWKGXFWWDSH
+RUL]RQWDOUXQVVKRXOGVORSHGRZQWRZDUGWKHRXWGRRUV
LQFKSHUIRRW
INSULATION
'XFWZRUNWKDWUXQVWKURXJKDQXQKHDWHGDUHDRULV
QHDUDLUFRQGLWLRQLQJVKRXOGEHLQVXODWHGWRUHGXFH
FRQGHQVDWLRQDQGOLQWEXLOGXS
4EXHAUST CONNECTION
THIS DRYER COMES READY FOR REAR EX-
HAUSTING. IF SPACE IS LIMITED, USE THE
INSTRUCTIONS IN STEP 9 TO EXHAUST
DIRECTLY FROM THE SIDE OR BOTTOM
OF THE CABINET.
WARNING - TO REDUCE THE RISK
OF FIRE OR PERSONAL INJURY:
7KLVFORWKHVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\µULJLGPHWDOGXFWLQJIRUWKHKRPHH[KDXVW
GXFW
8VH RQO\ µ ULJLG PHWDO RU 8/OLVWHG ÀH[LEOH PHWDO
VHPLULJLGRUIRLOW\SHGXFWWRFRQQHFWWKHGU\HUWRWKH
KRPHH[KDXVWGXFW,WPXVWEHLQVWDOOHGLQDFFRUGDQFH
ZLWKWKHLQVWUXFWLRQVIRXQGLQ´&RQQHFWLQJWKH'U\HUWR
+RXVH9HQWµRQSDJHVRIWKLVPDQXDO
'R QRW WHUPLQDWH H[KDXVW LQ D FKLPQH\ D ZDOO D
FHLOLQJJDVYHQWFUDZOVSDFHDWWLFXQGHUDQHQFORVHG
ÀRRURULQDQ\RWKHUFRQFHDOHGVSDFHRIDEXLOGLQJ7KH
DFFXPXODWHGOLQWFRXOGFUHDWHDSRWHQWLDO¿UHKD]DUG
1HYHUWHUPLQDWHWKHH[KDXVWLQWRDFRPPRQGXFWZLWK
D NLWFKHQ H[KDXVW V\VWHP $ FRPELQDWLRQ RI JUHDVH
DQGOLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG
'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVW
OHQJWK WDEOH /RQJHU GXFWV FDQ DFFXPXODWH OLQW
FUHDWLQJDSRWHQWLDO¿UHKD]DUG
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
ZLOOFDXVHOLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UH
KD]DUG
'R QRW DVVHPEOH GXFWZRUN ZLWK DQ\ IDVWHQHUV WKDW
H[WHQGLQWRWKHGXFW7KHVHIDVWHQHUVFDQDFFXPXODWH
OLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
'RQRWREVWUXFWLQFRPLQJRUH[KDXVWHGDLU
3URYLGHDQDFFHVVIRULQVSHFWLRQDQGFOHDQLQJRIWKH
H[KDXVWV\VWHPHVSHFLDOO\DWWXUQVDQGMRLQWV([KDXVW
V\VWHPVKDOOEHLQVSHFWHGDQGFOHDQHGDWOHDVWRQFHD
\HDU.
CONNECTING THE DRYER TO HOUSE VENT
RIGID METAL TRANSITION DUCT
)RU EHVW GU\LQJ SHUIRUPDQFH D ULJLG PHWDO WUDQVLWLRQ
GXFWLVUHFRPPHQGHG
5LJLGPHWDOWUDQVLWLRQGXFWVUHGXFHWKHULVNRIFUXVKLQJ
DQGNLQNLQJ
UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT
,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOH
PHWDOVHPLULJLGGXFWLQJFDQEHXVHG.LW:;;
1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
RWKHUHQFORVHGVSDFHV
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHG
IHHWP
DUCT TAPE OR
DUCT CLAMP
DUCT TAPE OR
DUCT CLAMP
4" METAL DUCT CUT
TO PROPER LENGTH
EXTERNAL DUCT
OPENING
For straight line installation, connect
the dryer exhaust to the external
exhaust hood using duct tape or
clamp.
NOTE: WE STRONGLY RECOMMEND SOLID
METAL EXHAUST DUCTING. HOWEVER, IF
FLEXIBLE DUCTING IS USED IT MUST BE
UL-LISTED METAL, NOT PLASTIC.
STANDARD REAR EXHAUST
(Vented at Àoor level)
STANDARD REAR EXHAUST
(Vented above Àoor level)
NOTE: ELBOWS WILL PREVENT DUCT
KINKING AND COLLAPSING.
ELBOW HIGHLY
RECOMMENDED
ELBOW HIGHLY
RECOMMENDED
RECOMMENDED
CONFIGURATION
TO MINIMIZE
EXHAUST
BLOCKAGE.

Installation Instructions
LEVELING YOUR DRYER
6WDQGWKHGU\HUXSULJKWQHDUWKH¿QDOORFDWLRQDQGDGMXVW
WKHOHYHOLQJOHJVDWWKHFRUQHUVWRHQVXUHWKDWWKHGU\HU
LVOHYHOIURPVLGHWRVLGHDQGIURQWWRUHDU
6ALCOVE OR CLOSET INSTALLATION
,I\RXUGU\HULVDSSURYHGIRULQVWDOODWLRQLQDQDOFRYHRU
FORVHWLWZLOOEHVWDWHGRQDODEHORQWKHGU\HUEDFN
7KH GU\HU MUST EH YHQWHG WR WKH RXWGRRUV 6HH WKH
EXHAUST INFORMATIONVHFWLRQV
0LQLPXPFOHDUDQFHEHWZHHQGU\HUFDELQHWDQGDGMDFHQW
ZDOOVRURWKHUVXUIDFHVLV
LQHLWKHUVLGH
LQIURQW
LQUHDU
0LQLPXPYHUWLFDOVSDFHIURPÀRRUWRRYHUKHDGFDELQHWV
FHLOLQJHWFLVLQ
&ORVHW GRRUV PXVW EH ORXYHUHG RU RWKHUZLVH YHQWLODWHG
DQGPXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHD
HTXDOO\GLVWULEXWHG,IWKHFORVHWFRQWDLQVERWKDZDVKHU
DQGDGU\HUGRRUVPXVWFRQWDLQDPLQLPXPRIVTLQ
RIRSHQDUHDHTXDOO\GLVWULEXWHG
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF
THE DRYER, MINIMUM CLEARANCE FROM THE WALL IS 5.5 in.
5
LEVEL
SIDE-TO-SIDE
4 LEVELING
LEGS
LEVEL
FRONT-TO-BACK
)RUPDQ\DSSOLFDWLRQVLQVWDOOLQJHOERZVDWERWKWKHGU\HU
DQG WKH ZDOO LV KLJKO\ UHFRPPHQGHG VHH LOOXVWUDWLRQV
EHORZ (OERZV DOORZ WKH GU\HU WR VLW FORVH WR WKH ZDOO
ZLWKRXW NLQNLQJ DQG RU FUXVKLQJ WKH WUDQVLWLRQ GXFW
PD[LPL]LQJGU\LQJSHUIRUPDQFH
$YRLGUHVWLQJWKHGXFWRQVKDUSREMHFWV
UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT
,Q VSHFLDO LQVWDOODWLRQV LW PD\ EH QHFHVVDU\ WR FRQQHFW
WKH GU\HU WR WKH KRXVH YHQW XVLQJ D ÀH[LEOH PHWDO IRLO
W\SH GXFW $ 8/OLVWHG ÀH[LEOH PHWDO IRLOW\SH GXFW PD\
EHXVHG21/<LQLQVWDOODWLRQVZKHUHULJLGPHWDORUÀH[LEOH
PHWDOVHPLULJLGGXFWLQJFDQQRWEHXVHG$1'ZKHUHDµ
GLDPHWHUFDQEHPDLQWDLQHGWKURXJKRXWWKHHQWLUHOHQJWK
RIWKHWUDQVLWLRQGXFW
,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDO
IRLOW\SHGXFWVWKDWFRPSO\ZLWKWKH´2XWOLQHIRU&ORWKHV
'U\HU7UDQVLWLRQ'XFW6XEMHFW$µVKDOOEHXVHG
1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
RWKHUHQFORVHGVSDFHV
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW
P
$YRLGUHVWLQJWKHGXFWRQVKDUSREMHFWV
For best drying performance
6OLGH RQH HQG RI WKH GXFW RYHU WKH FORWKHV GU\HU RXWOHW
SLSH
6HFXUHWKHGXFWZLWKDFODPS
:LWKWKHGU\HULQLWVSHUPDQHQWSRVLWLRQH[WHQGWKHGXFW
WRLWVIXOOOHQJWK$OORZµRIGXFWWRRYHUODSWKHH[KDXVW
SLSH&XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDV
VWUDLJKWDVSRVVLEOHIRUPD[LPXPDLUÀRZ
6HFXUHWKHGXFWWRWKHH[KDXVWSLSHZLWKWKHRWKHUFODPS
7
BATHROOM OR BEDROOM INSTALLATION
7KHGU\HU0867EHYHQWHGWRWKHRXWGRRUV6HH(;+$867
,1)250$7,21VHFWLRQ
7KHLQVWDOODWLRQPXVWFRQIRUPZLWKORFDOFRGHVRULQWKH
DEVHQFHRIORFDOFRGHVZLWK WKH 1$7,21$/ (/(&75,&$/
&2'($16,1)3$12

Installation Instructions
10 DRYER EXHAUST TO RIGHT, LEFT OR
BOTTOM CABINET
WARNING - BEFORE PERFORMING
THIS EXHAUST INSTALLATION, BE SURE
TO DISCONNECT THE DRYER FROM ITS
ELECTRICAL SUPPLY. PROTECT YOUR
HANDS AND ARMS FROM SHARP EDGES
WHEN WORKING INSIDE THE CABINET.
BE SURE TO WEAR GLOVES.
Detach and remove the bottom, right or left side knockout
as desired. Remove the screw inside the dryer exhaust duct
and save. Pull the duct out of the dryer.
REMOVE
SCREW
AND SAVE.
REMOVE DESIRED
KNOCKOUT (ONE ONLY).
Cut the duct as shown and keep portion A.
11 1/4"
AB
FIXING HOLE
MOBILE OR MANUFACTURED HOME
INSTALLATION
,QVWDOODWLRQPXVWFRQIRUPWRWKH0$18)$&785('+20(
&216758&7,21 6$)(7< 67$1'$5' 7,7/( 3$57
RU ZKHQ VXFK VWDQGDUG LV QRW DSSOLFDEOH ZLWK
$0(5,&$1 1$7,21$/ 67$1'$5' )25 02%,/( +20(
$16,1)3$12%
7KH GU\HU 0867 EH YHQWHG WR WKH RXWGRRUV ZLWK WKH
WHUPLQDWLRQ VHFXUHO\ IDVWHQHG WR WKH PRELOH KRPH
VWUXFWXUH6HH(;+$867,1)250$7,21VHFWLRQ
7KHYHQW0867127EHWHUPLQDWHGEHQHDWKDPRELOHRU
PDQXIDFWXUHGKRPH
7KHYHQWGXFWPDWHULDO0867%(0(7$/
'RQRWXVHVKHHWPHWDOVFUHZVRURWKHUIDVWHQLQJGHYLFHV
ZKLFKH[WHQGLQWRWKHLQWHULRURIWKHH[KDXVWYHQW
6HHVHFWLRQIRUHOHFWULFDOFRQQHFWLRQLQIRUPDWLRQ
8
GARAGE INSTALLATION (IF ALLOWED
BY LOCAL CODES)
'U\HUV LQVWDOOHG LQ JDUDJHV PXVW EH HOHYDWHG LQFKHV
FPDERYHWKHÀRRU
9
TAB LOCATION
ADDING NEW DUCT
5HFRQQHFWWKHFXWSRUWLRQ$RIWKHGXFWWRWKHEORZHU
KRXVLQJ0DNHVXUHWKDWWKH¿[LQJKROHLVDOLJQHGZLWKWKH
WDELQWKHEDVH8VHWKHVFUHZVDYHGSUHYLRXVO\WRVHFXUH
WKHGXFWLQSODFHWKURXJKWKHWDERQWKHDSSOLDQFHEDVH
ADDING ELBOW AND DUCT FOR
EXHAUST TO LEFT SIDE OF CABINET
3UHDVVHPEOHµHOERZZLWKµGXFW:UDSGXFWWDSH
DURXQGMRLQW
,QVHUWGXFWDVVHPEO\HOERZ¿UVWWKURXJKWKHVLGH
RSHQLQJDQGFRQQHFWWKHHOERZWRWKHGU\HULQWHUQDOGXFW
CAUTION: Be sure not to pull or damage the
electrical wires inside the dryer when inserting the duct.
$SSO\GXFWWDSHDVVKRZQRQWKHMRLQWEHWZHHQWKHGU\HU
LQWHUQDOGXFWDQGWKHHOERZ
Through the rear opening, locate the tab in the middle of
the appliance base. Lift the tab to about 45º using a flat
blade screwdriver.
BEND TAB
UP 45 o
RIGHT OR
LEFT SIDE
EXHAUST
PORTION "A"
FIXING
HOLE
EXHAUST CAN
BE ADDED TO
LEFT OR RIGHT SIDE
DUCT
TAPE

Installation Instructions
$SSO\GXFWWDSHDVVKRZQRQWKHMRLQWEHWZHHQWKH
GU\HULQWHUQDOGXFWDQGWKHHOERZ
ADDING ELBOW FOR EXHAUST
THROUGH BOTTOM OF CABINET
,QVHUWWKHHOERZWKURXJKWKHUHDURSHQLQJDQGFRQ
QHFWLWWRWKHGU\HULQWHUQDOGXFW
$SSO\GXFWWDSHRQWKHMRLQWEHWZHHQWKHGU\HULQWHU
QDOGXFWDQGHOERZDVVKRZQDERYH
ADDING COVER PLATE TO REAR
OF CABINET (SIDES AND BOTTOM
EXHAUST
&RQQHFWVWDQGDUGPHWDOHOERZVDQGGXFWVWRFRPSOHWH
WKHH[KDXVWV\VWHP&RYHUEDFNRSHQLQJZLWKD
SODWH.LW:(0DYDLODEOHIURP\RXUORFDOVHUYLFH
SURYLGHU3ODFHGU\HULQ¿QDOORFDWLRQ
DUCT
TAPE
CAUTION:
Internal duct joints must be
secured with tape, otherwise
they may separate and cause a
safety hazard.
CAUTION:
Internal duct joints must be secured with tape,
otherwise they may separate and cause a
safety hazard.
PL ATE
(KIT WE1M454)
WARNING-NEVER LEAVE THE
BACK OPENING WITHOUT THE PLATE
(Kit WE1M454).
REVERSING THE DOOR SWING
(OPTIONAL)
IMPORTANT NOTES
5HDGWKHLQVWUXFWLRQVDOOWKHZD\WKURXJKEHIRUHVWDUWLQJ
+DQGOHSDUWVFDUHIXOO\WRDYRLGVFUDWFKLQJSDLQW
6HW VFUHZV GRZQ E\ WKHLU UHODWHG SDUWV WR DYRLG XVLQJ
WKHPLQWKHZURQJSODFHV
3URYLGHDQRQVFUDWFKLQJZRUNVXUIDFHIRUWKHGRRUV
1RUPDOFRPSOHWLRQWLPHWRUHYHUVHWKHGRRUVZLQJLV
PLQXWHV
IMPORTANT:2QFH\RXEHJLQGRQRWPRYHWKH
FDELQHWXQWLOGRRUVZLQJUHYHUVDOLVFRPSOHWHG
7KHVH LQVWUXFWLRQV DUH IRU FKDQJLQJ WKH KLQJHV
IURPWKH ULJKW VLGH WR WKH OHIWVLGHLI\RXHYHU
ZDQW WR VZLWFK WKHP EDFN WR WKH ULJKW VLGH
IROORZ WKHVH VDPH LQVWUXFWLRQV DQG UHYHUVH DOO
UHIHUHQFHVWRWKHOHIWDQGULJKW
11
TOOLS YOU WILL NEED
&UHVFHQW:UHQFK
$GMXVWDEOH
3KLOOLSV+HDG6FUHZGULYHU
3XWW\.QLIHRU7KLQ
%ODGH6FUHZGULYHU
DOOR PARTS
/DUJH7DSSLQJ
6FUHZ²
+LQJH
$VVHPEO\
+LQJH
&RYHU 3ODVWLF&RYHU
:DVKHU²
1XW²
0DFKLQH
6FUHZ
²
7DSSLQJ6FUHZ
²

BEFORE YOU START
8QSOXJWKHGU\HUIURPLWVHOHFWULFDORXWOHW
Installation Instructions
REMOVE DOOR ASSEMBLY
2SHQWKHGRRUWRDSSUR[LPDWHO\GHJUHHV5HPRYHWKH
VFUHZVVWDUWLQJIURPWKHERWWRPWRWKHWRS0DNHVXUH
WKHGRRULVVXSSRUWHGZKLOHUHPRYLQJWKHVFUHZV
/RRVHQ WKH WRS VFUHZ DV VKRZQ 8QKRRN WKH GRRU E\
OLIWLQJDQGSXOOLQJDVVKRZQE\WKHDUURZV
Remove the
four screws.
/D\ WKH GRRU GRZQ RQ D VRIW SURWHFWHG ÀDW VXUIDFH VR
WKDW WKH LQQHU SDUW IDFHV XSZDUG GRRU UHVWLQJ RQ WKH
KDQGOHVLGH
5HPRYHWKHODUJHWDSSLQJVFUHZVORFDWHGDURXQG
WKHSHULPHWHURIWKHGRRURXWOLQLQJWKHJDVNHWDQGWKH
PDFKLQHVFUHZVRQWKHKLQJHVLGH
:LWK WKH VFUHZV UHPRYHG WXUQ WKH GRRU RYHU DQG
VHSDUDWHWKHVLOYHUFRYHUSDUWRIWKHGRRUIURPWKHGRRU
IUDPHDQGVHWDVLGH
8QORFN WKH WDEV RQ WKH SODVWLF FRYHU DQG VHSDUDWH
WKHSODVWLFFRYHUIURPWKHIUDPH
NOTE:'LVUHJDUGWKH´'21275(029(µODEHORQWKHSODVWLF
FRYHU
6 #10 Large
Screws
2 #8 Machine
Screws
2 #8 Machine
Screws

Installation Instructions
REMOVE HINGE
IMPORTANT: 1RWH WKH ORFDWLRQ RI WKH KLQJH OHIW RU ULJKW
EHIRUHUHPRYLQJ
:LWK WKHGRRUIUDPHSDUW RI WKH GRRU ODLG GRZQRQD
SURWHFWHG VRIW VXUIDFH UHPRYH WKH KLQJH FRYHU E\
UHPRYLQJWKHWDSSLQJVFUHZVWKDWIDVWHQLWWRWKH
IUDPH7KHKLQJHFRYHULVORFDWHGDWWKHRSSRVLWHVLGHRI
WKHKLQJHDVVHPEO\
5HPRYHWKHQXWVZDVKHUVDQGWKHPDFKLQHVFUHZV
5HPRYHWKHKLQJHDVVHPEO\E\UHPRYLQJWKHPDFKLQH
VFUHZVWKDWIDVWHQLWWR WKH IUDPH 3XOO WKH KLQJH
DVVHPEO\RXWDQGVHWLWDVLGH
REINSTALL HINGE ASSEMBLY
3ODFHWKHKLQJHDVVHPEO\LQWKHRSSRVLWHVLGHRIWKH
GRRU
/RRVHO\IDVWHQWKHKLQJHDVVHPEO\WRWKHHGJHXVLQJ
PDFKLQHVFUHZV
+ROG WKH GRRU RQ LWV VLGH ZLWK RQH KDQG DQG IDVWHQ
WKHUHPDLQLQJVFUHZVDVVKRZQ7KHQWLJKWHQWKH
VFUHZVKROGLQJWKHKLQJHDVVHPEO\

Installation Instructions
REINSTALL NUTS AND HINGE COVER
3ODFHWKHGRRURQLWVHGJH$VVHPEOHWKHPDFKLQH
VFUHZVZDVKHUVDQGQXWV7LJKWHQXVLQJDZUHQFK
DQGVFUHZGULYHU
3ODFHWKHKLQJHFRYHULQSRVLWLRQ$OLJQWKHKLQJHFRYHU
KROHVZLWKWKHKROHVLQWKHGRRU
6HFXUHWKHKLQJHFRYHUZLWKWKHWDSSLQJVFUHZV
REASSEMBLE DOOR ASSEMBLY
IMPORTANT: 0DNHVXUHWKHUHLVQRGLUWRUDQ\RWKHUIRUHLJQ
PDWHULDOLQEHWZHHQWKHZLQGRZSDQHV
3ODFHWKHSODVWLFFRYHURQWRWKHLQQHUGRRUDQGORFNLQ
SODFHZLWKWKHWDEV
3ODFHWKHRXWHUGRRURQWRWKHLQQHUGRRU
$IWHUUHYHUVLQJGRRUWKHUHZLOOEHDPLVPDWFKEHWZHHQ
WKHRXWHUGRRUDQGWKHLQQHUGRRU
0DNHVXUHWKDWWKHKDQGOHSDUW RI WKH RXWHU GRRU LV
RSSRVLWHWKHKLQJHDVVKRZQ

Installation Instructions
7XUQWKH GRRURYHUDQGIDVWHQWKHRXWHUGRRUWRWKH
LQQHUGRRUXVLQJWKHODUJHWDSSLQJVFUHZV
MOVE STRIKE BRACKET
8VLQJDSXWW\NQLIHRUDQ\RWKHUÀDWWRROUHPRYHWKH
SODVWLFVFUHZFDSVORFDWHGRQWKHGU\HUZKHUHWKH
GRRUZLOOEHLQVWDOOHGDQGLQVWDOOWKHPRQWKHRSSRVLWH
VLGH
6ZLWFKWKHVWULNHEUDFNHWDQGLWVFRYHUWRWKHRSSRVLWH
VLGHE\UHPRYLQJWKHVFUHZVWKHQUHLQVWDOOERWKRQWKH
RSSRVLWHVLGH
REINSTALL DOOR ASSEMBLY
7KH GRRU LV QRZ UHDG\ WR EH LQVWDOOHG RQ WKH GU\HU
7RHDVHWKLVVWHSWKHKLQJHKDVNH\KROHVWKDWDOORZD
SDUWLDOO\IDVWHQHGVFUHZWREHXVHGDVDKRRN
3DUWLDOO\IDVWHQDVFUHZWRWKHXSSHUPRVWVFUHZKROH
+RRNWKHGRRURQWKHSDUWLDOO\IDVWHQHGVFUHZ
)DVWHQWKHKLQJHE\LQVWDOOLQJWKHRWKHUVFUHZVDQG
WLJKWHQLQJWKHSDUWLDOO\IDVWHQHGVFUHZDERYH
5(*,67(5<2851(:$33/,$1&(725(&(,9($1<
,03257$17352'8&7127,),&$7,216
3OHDVHJRWR www.GEAppliances.comRUPDLOLQ
\RXUSURGXFWUHJLVWUDWLRQFDUG
)RUTXHVWLRQVRQLQVWDOODWLRQFDOO86RU
&DQDGD
12
SERVICING
WARNING-LABEL ALL WIRES
PRIOR TO DISCONNECTING WHEN
SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION AFTER
SERVICING/INSTALLATION.

Installation Instructions
30 5/8"27"
40 1/4"
53 5/8"
39 1/8"
13 3/8"
11 3/4"
17"
27" 1 5/8"
4 1/2"
31 1/8"
41 1/2"
11 3/4"
ROUGH-IN DIMENSIONS
Other manuals for DCVH680EJWW
1
This manual suits for next models
1
Table of contents
Other GE Dryer manuals
Popular Dryer manuals by other brands

Alliance Laundry Systems
Alliance Laundry Systems Drying Tumbler 110 Pound Capacity Part No.... operating & maintenance manual

NEFF
NEFF R8580X2ES Installation and operating instructions

Samsung
Samsung DVE54CG7550 Series user manual

Cissell
Cissell L28FD30 Installation & operation

Dolphin Velocity
Dolphin Velocity BC220IISS user manual

Whirlpool
Whirlpool WGD5590VQ1 installation instructions