GE Monogram ZV800 User manual

Installation
Instructions
36" ChimneyVent Hood
ZV800
Monogram:

Safety Information
BEFORE YOU BEGIN
Readthese instructionscompletelyandcarefully.
"IMPORTANT-save theseinstructionsfor
localinspector's use.
IMPORTANT- Observeall governing
codes and ordinances.
•Note to Installer -- Besureto leavethese
instructions with the Consumer.
•Note to Consumer -- Keeptheseinstructions
with your Owner's Manual for future reference.
•Skill Level --Installation of this appliance requires
basic mechanical and electrical skills.
• Completion "13me -- 1 to 3 Hours.
• Proper installation is the responsibility of the installer.
Product failure dueto improper installation is not covered
under the warranty.
ForMonogramlocal service in your area, 1.800.444.1845.
ForMonogramservice in Canada1.888.880.3030
ForMonogramParts and Accessories,call 1.800.626.2002.
CAUTION:
Dueto the weight and size of these vent hoods andto
reduce the risk of personal injury or damageto the product,
13/VOPEOPLEAREREQUIREDFORPROPERINSTALLATION.
PRUDENCE:
_,cause du poids et de la taille de ces hottes et pour
reduire le risque de blessures et de dommages,IL FAUT
DEUXPERSONNESPOURFAIREL'INSTALLATION
CORRECTEMENT.
WARNING:
Toreduce the risk of fire or electrical shock, do not
usethis range hood with any external solid-state speed
control device. Any such alteration from original factory
wiring could result in damageto the unit and/or create an
electrical safety hazard.
ADVERTISSEMENT :
Pour rCduirele risque d'incendie ou de choc 61ectrique,
il ne faut pasutiliser cette hotte avec un rCgulateur de
vitesse 61ectroniqueexterne. Toutemodification de ce
type du branchement d'usine peuteendommager
I'appareil ou crCer un risque de choc 61ectrique.
TO REDUCETHERISKOFFIRE,USEONLYMETAL
DUCTW0RK.
WARNING: TOREDUCETHERISKOFFIRE,
ELECTRICALSHOCKORINJURYTOPERSONS,OBSERVE
THE FOLLOWING:
A. Usethis unit only in the manner intended bythe
manufacturer. If you have any questions, contact the
manufacturer.
S. Before servicing or cleaning unit, switch power off at
the service panel and lock service panel to prevent
power from being switched on accidentally. If the
service panel cannot be locked, fasten a tag or
prominent warning label to the panel.
ADVERTISSEMENT :
POURRI_DUIRELERISQUED'INCENDIE,DECHOC
I_LECTRIQUEOUDEBLESSURES,IL FAUTOBSERVERLES
REGLESSUIVANTES:
A. Utiliser cet appareil uniquement de la maniCre prCvue
par le fabricant. En cas de question, consulter le
fabricant.
B. Avanttoute intervention ou nettoyage, couper
I'alimentation 61ectriqueau disjoncteur et verrouiller
le panneau du disjoncteur pour 6viter la raisesous
tension accidentelle. S'il n'est pas possible de
verrouiller le panneau du disconcteur, attacher un
placard ou une 6tiquette trCs visible au panneau.
• Forgeneral ventilating useonly. Do not useto exhaust
hazardous or explosive materials or vapors.
• Structural framing, installation work and electrical
wiring must be done byqualified person(s).
In accordance with all applicable codes and
standards including fire-rated construction.
• Sufficient air is needed for proper combustion and
exhausting of gasesthrough the flue (chimney) of fuel
burning equipment to prevent back drafting. Followthe
heating equipment manufacturer's guideline and safety
standards such as those published bythe National Fire
Protection Association (NFPA),and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE),and the local code authorities.
• Local codes vary. Installation electrical connections and
grounding must comply with applicable codes. In the
absence of local codes, the vent should be installed in
accordance with National Electrical CodeANSI/NFPA
70-1990or latest edition.
"^_ UTION: Toreduce risk of fire and to
properly exhaust air, be sure to duct air outside - do not
vent exhaust air into spaces within walls or ceilings or into
attics, crawl spaces, or garages.
PRUDENCE : IIfautprendre soind'installer
un conduit vers I'extCrieur pour rCduirele risque d'incendie
et pouvoir 6vacuer I'air correctement. II ne faut pas6vacuer
I'air correctement. II ne faut pas6vacuer I'air dans I'espace
entre les parois d'un tour,un plafond ou ungrenier,
un espace sanitaire ou un garage.
2

Design Information
CONTENTS
Design Information
Product Dimensions and Clearances .................................................. 3
Installation Options ................................................................................ 3
Advance Planning, Ductwork, Framing .............................................. 4
Power Supply .......................................................................................... 4
Duct Fittings .............................................................................................. 5
Installation Preparation
Tools and Materials Required .............................................................. 6
Remove the Packaging .......................................................................... 6
Wall Mount Installations ........................................................................ 7
Installation Below a Wall Cabinet ........................................................ 7
Check Installation Hardware ................................................................ 8
Ductwork, Wiring Locations .................................................................. 9
Wall-Mounted Installation -Vented to the Outside
Step 1, Install Framing for Hood Support ............................................ 9
Step 2, Install Mounting Bracket ........................................................ 10
Step 3, Install Duct Bracket ................................................................ 10
Step 4, Prepare the Hood .................................................................... 11
Step 5, Mount the Hood ...................................................................... 11
Step 6, Connect Ductwork .................................................................. 12
Step 7, Connect Electrical .................................................................... 12
Step 8, Install Duct Covers .................................................................. 13
Step 9, Install Filters .............................................................................. 13
Step 10, Finalize Installation ................................................................ 13
Wall-Mounted Installation -Recirculating
Ductwork, Wiring Locations ................................................................ 14
Step 1, Install Framing for Hood Support .......................................... 14
Step 2, Install Mounting Bracket ........................................................ 15
Step 3, Prepare the Hood .................................................................... 15
Step 4, Mount the Hood ...................................................................... 16
Step 5, Size and Cut Duct Piece ........................................................ 16
Step 6, Connect Electrical .................................................................... 17
Step 7, Install Duct Covers .................................................................. 17
Step 8, Install Filters .............................................................................. 18
Step 9, Finalize Installation .................................................................. 18
Under-Cabinet Installation
Cabinet Requirements .......................................................................... 19
Ductwork, Wiring .................................................................................. 19
Step 1, Install Framing for Hood Support .......................................... 20
Step 2, Prepare the Hood .................................................................... 20
Step 3, Cut the Opening ........................................................................ 21
Step 4, Install Side "L" Brackets ........................................................ 21
Step 5, Remove Side Screw ................................................................ 21
Step 6, Mount the Hood ...................................................................... 22
Step 7, Complete Installation and Connect Ductwork ....................22
Step 8, Connect Electrical .................................................................... 23
Step 9, Install Rear Mounting Screws .............................................. 23
Step 10, Install Filters ............................................................................ 23
PRODUCT DIMENSION AND
CLEARANCE
* Heightto
Ceiling
NOTE:Theventhood
canopyextends
forward5-7/8".
1-1/2"
12-15/16"atSides,
13-11/16"at Center
35-7/8"
* TheSuppliedDuctCoverFits8ft.to10ft.
CeilingHeights
Thevent hoodmustbeinstalled24" min.,and 30"max.above
the cookingsurface.Thetelescopic duct cover concealsthe
ductwork runningfrom thetop ofthehoodtothe ceiling.
Theduct coverissizedto reach8ft.to 10fL ceilingheights.
Thehoodinstallationheight,fromthe cookingsurfaceto the
bottomofthe hood,dependsuponceilingheighL
INSTALLATION OPTIONS
24" Min.
30" Max.
WALL-MOUNTED INSTALLATIONS
Thishoodmaybe installedontoa wall andventedtothe
outdoors,or it canbeinstalledfor recirculatingoperation.
All necessarypartsfor a recirculatingoperationareshipped
with the hood.Nokitsrequired.
*24" Min.
*Depending on CabinetHeight
UNDER-CABINET INSTALLATIONS
Thehood maybeinstalledbeneatha cabinet.Thecabinetmust
measureat least20"from the bottomframetothe insidetop.
Seepage 19.
•Bothventedandrecirculatingoperationcanbe accomplished
in an under-cabinetinstallation.(Customcabinetmodification
is requiredfor recirculatingoperation.)
3

Installation Preparation
ADVANCE PLANNING
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible.
For satisfactory performance, duct run should not
exceed 100ft. equivalent length for any duct
configurations.
•Refer to "Duct Fittings" chart to compute the
maximum permissible length for duct runs to the
outdoors.
UTION: To reduce risk of fire and to
properly exhaust air, be sure to duct air outside -
do not vent exhaust air into spaces within walls or
ceilings or into attics, crawl spaces, or garages.
PRUDENCE : Ilfautprendre soin
d'installer un conduitvers I'ext_rieur pour r_duire le
risque d'incendie et pouvoir _vacuer I'air correctement.
II ne faut pas _vacuer I'air correctement. II ne faut pas
_vacuer I'air dans I'espace entre les parois d'un mur,
un plafond ou un grenier, un espace sanitaire ou un
garage.
•Use metal ductwork only. These hoods must use
6" round duct. It can transition to 3-1/4" x 12",
reducing the maximum equivalent duct length to
75 feet.
• Install a wall cap with damper or roof cap at the
exterior opening. Order the wall or roof cap and any
transition needed in advance.
Wall Framing for Adequate Support
• This vent hood is heavy. Adequate structural support
must be provided in all types of installations. The
hood must be secured to vertical studs in the wall,
or to a horizontal support. For wall mounting
installations, see pages 9 and 14. For under-cabinet
installations, see page 20.
• The vent hood and wall cabinet, if used, should be on
site before final framing and wall finishing. This will
also help to accurately locate the duct work and
electrical service.
POWER SUPPLY
IMPORTANT- (Please read carefully)
WARNING:
FOR PERSONAL SAFETY,THIS APPLIANCE MUST BE
PROPERLYGROUNDED.
ADVERTISSEMENT :
POUR DES RAISONS DE SI_CURITI_,CET APPAREIL
DOlT ETRECORRECTEMENT MIS _, LA TERRE.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National electrical codes or
prevailing local codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V,60Hz, and
connected to an individual, properly grounded branch
circuit, and protected by a 15 or 20 amp circuit breaker
or time delay fuse.
•Wiring must be 2 wire with ground.
•If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
•Route house wiring through conduit as close to the
installation location as possible, in the ceiling or
backwall.
•Use a conduit connector to secure the conduit to
the junction box.
•Connect the wiring to the house wiring in accordance
with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING: The improper connection of
the equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service representative if you are in doubt whether the
appliance is properly grounded.
ADVERTISSEMENT :
Le mauvais branchement du fil de mise _ la terre peut
causer un choc _lectrique. En cas de doute, consulter
un _lectricien qualifi_ ou un technicien pour d_terminer
si I'appareil est _ la terre.

Installation Preparation
DUCT FITTINGS
Use this chart to compute maximum
permissable lengths for duct runs
to outdoors.
NOTE: Do not exceed maximum
permissable equivalent lengths!
Maximum duct length:
100 foot for 6" round duct
75 foot for 3-1/4" x 12" duct
Flexible ducting:
If flexible metal ducting is used,
all the equivalent feet values in
the table should be doubled.
The flexible metal duct should be
straight and smooth and extended
as much as possible.
DO NOT use flexible plastic ducting.
NOTE: Any home ventilation system,
such as a ventilation hood, may
interrupt the proper flow of
combustion air and exhaust
required by fireplaces, gas
furnaces, gas water heaters and
other naturafly vented systems. To
minimize the chance of interruption
of such naturafly vented systems,
follow the heating equipment
manufacturer's guidelines and
safety standards such as those
published by NFPA and ASHRAE.
Equivalent Quantity
DuctPiece Dimensions Length* Used
Round, I ft.
straight (per foot
length)
3-1/4" x 12" 1ft.
3-1/4" x 24" (per foot
straight length)
(_ 6" Round
90° elbow 15ft.
6" Round
45° elbow 8 ft.
] 3-V4" x 12"
90° elbow 11ft.
3-1/4" x 12" or
45° elbow 6 ft.
3-1/4" x 12"
90° flat elbow 24ft.
_,_,_ 6" round to
3-1/4" x 12"
or 3-1/4" x 24" transition 1ft.
_,_ 3-1/4" x 12"to 6"
round transition 8 ft.
_ 6" round
to 3-1/4" x 12" or
transition 90° elbow 16ft.
_ 3-1/4" x 12"to 6" round
round transition 90° elbow 17ft.
_ 6" round
wall cap
with damper 30ft.
[_ 3-1/4" x 12" wall cap
with damper 30ft.
1) 6" Round
roof cap 26ft.
6" Round
roof vent 26ft.
*Actual length of straight duct plusduct
fitting equivalent. Equivalent length of duct
pieces are based on actual tests conducted Total Duct Run
by 6E Evaluation Engineering and reflect
requirements for good venting performance
with anyventilation hood.
Total
Equivalent
Length
5

Installation Preparation
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
[] Tapemeasure
[] Knife
[] Spirit level
[] Wire cutter/stripper
[] Wire nuts
[] Electric drill with 1/8"and 3/8"bits
[] Phillips and flat blade screwdrivers
[] Hammer
[] Pliers
[] Safetyglasses
[] Ducttape
[] Tapeto mount template
[] Glovesto protect against sharp edges
[] 120V60Hz.15or 20Amp, 2wire with
ground Properly grounded branch circuit
[] Strain relief for junction cover
[] 6" round metal duct, lengthto suit
installation
[] Saw or jig saw
[] Conduitfor housewiring
and conduit connector
Measuring Tape
Pliers
Duct Tape
Strain relief for
junction cover
Spirit level
Electric drill
with 1/8" and
3/8" Bits
Safety glasses
Phi_ Flat blade
head "_ screwdriver
screwdriver
Wire nuts Masking tape Conduit
Gloves
Knife
Wire
cutter/stripper
Hammer
Saw or jig saw
REMOVE THE PACKAGING
2-piece duct
cover
• Remove the duct cover, parts box and other
packaging.
• Lift the hood out of the box.
• Remove and properly discard the plastic wrapping.
• Remove junction box cover.
6

Installation Preparation
WALL MOUNT INSTALLATIONS
These hoods may be installed onto a wall or below a
wall cabinet.
• Telescopic duct covers are provided to conceal the
ductwork, running to the ceiling.
• This hood can be installed for recirculating operation.
No kits required.
36" Min.
o
The vent hood must be installed 24" min, and 30" max,
above the cooking surface. The hood installation
height, from the cooking surface to the bottom
of the hood, depends upon ceiling height,
INSTALLATION BELOW A CABINET
24" Min.
*The cabinet must measure at least 20"from the bottom
frame to the inside top. The hood housing will occupy the
interior cabinet space.
Actual
Celing
Height
7'11"
8'0"
8'1"
8'2"
8'3"
8'4"
8'5"
8'8"
8'7"
8'8"
8'9"
8' 10"
8'11"
9'0"
9'1"
9'2"
9'3"
9'4"
9'5"
9'6"
9'7"
9'8"
9'9"
9'10"
9'11"
10'
*Possible VENTED
InstallationHeight
24"to 27"
24"to 28"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
25"to 30"
26"to 30"
27"to 30"
28"to 30"
29"to 30"
30"
*Possible
RECIRCULATING
InstallationHeight
24"to 25"
24"to 28"
24"to 27"
24"to 28"
24"to 29"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
24"to 30"
25"to 30"
26"to 30"
*Based on 36" countertop height.
INSTALLATION BELOW
A WALL CABINET
Order a cabinet that is at least 20" high from the
bottom frame to the inside top. The cabinet must be
at least 12" deep.
• The hood installation height is determined bythe
ceiling height.
• The hood installation height must be 24" Min. above
the cooking surface.

Installation Preparation
CHECK INSTALLATION HARDWARE
Locate the hardware accessory box packed with the hood and check contents.
i4 wood
screws 4 wall
fasteners
I j
Air deflector for
recirculating
installations only
Duct bracket
Discharge damper
2 stainless steel filters
"L" Brackets with hardware
package for cabinet-mounted
installations.
Contains10Phillips head screws
to secure the brackets to the
cabinet (8 required, 2 extra)
Mounting bracket
3 Phillips head
screws to secure
electrical boxto
top of motor
compartment
TTTT
4 Phillips head decorative
screws to secure duct cover
to ceiling bracket
29 j4
2-piece decorative duct
cover (dimension shown
for reference only)
1 charcoal filter for
recirculating installations
I
it i"
_ii_I _
=_i i."l
i!'_II_ _
TOP CABINETTEMPLATE
I
Cabinet installation template
RE,_RWAI
t
TEMPLATE
41-
Wall mount template
8

Installation Instructions
WALL-MOUNTEDINSTALLATION--VENTEDTO THEOUTSIDE
DUCTWORK, WIRING LOCATIONS
Determine the exact location ofthe vent hood,
• Locate the template packed with the literature.
- Measure 36" from the floor to the top of the cooking
surface. Add hood installation height determined on
page 7. Markthat location,
- Use a level to draw a straight pencil line on the wall,
3-3/4" ceoterlioe to wall --4"j_,_- FORCEILINGVENTBUCTING
i _ Ceiling
6-1/2" din. hole _/
\\ Centerline 3-3/4"
\ min. abovetop
mounting bracket
FORWALLVENTDUCT-_----- holes
o
!
!
I
fI
REARWAL!TEMPLATE
- Tapethe template in position along the penciled
line. CHECKTO BE SURETHE TEMPLATEIS LEVEL.
Ceiling ducting:
If ductwork will vent straight up to the ceiling:
• Use a level to draw a line straight up,from the centerline
on the template to the ceiling.
•Measure 3-3/4" from the back wall to the centerline of
a 6-1/2" hole on the ceiling.
NOTE:If drvwall is not present, add drvwall thickness to
the 3-3/4" dimension.
Wall Ducting:
If ductwork will vent to the rear:
•Use a level to draw a line straight up from the centerline
on the template.
• Measure at least 3-3/4" above the top mounting bracket
holes shown on the template to the centerline of a
6-1/2" dia. duct hole. (Hole may be elongated for
duct elbow.)
HOUSEWIRING LOCATION:
• The junction box is located on the top right side of the
hood.
• Wiring should enter the back wall 20" to 26" above the
bottom of the hood, and within 4" of the right side of the
centerline. Wiring should enter at least 4" above the
bracket on the right side. 9
INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT- Framingmustbe capable of
supporting100Ibs.
6" min. opening for ductwork
View from rear
cleats
1" x 6" rain.
mounting
support
Centerline of
installation ]
If drywall is present, markthe screw hole locations for
the top mounting brackets. Remove the template.
• Cut away enough drywall to expose 2 vertical studs at
the bracket location indicated on the template,
• Install a horizontal support at least 1" x 6" between
two wall studs atthe top bracket installation location,
The horizontalsupportmust beflushwith the room
side ofthe studs.Usecleats behind both sides ofthe
support to secure to wall studs,
• Reinstall drywall.

Installation Instructions
WALL-MOUNTEDINSTALLATION--VENTEDTO THEOUTSIDE
[] INSTALL MOUNTING BRACKET
This vent hood must be secured to the horizontal
support or wall studs.
•With the template taped in place, use a punch to
mark all mounting screw locations,
• Drill 1/8" pilot holes atthe 6 punched locations.
• Remove the template,
• The 2 holes in the support bracket holes must enter
studs or the horizontal support,
• Use wood screws to secure the mounting bracket
to the wall, The screws must engage wall studs or
the installed horizontal mounting support.
• Check to be sure that the bracket is level. There is
no way to level the hood after hanging it from this
bracket.
[_ INSTALL DUCT BRACKET
The duct bracket must be intalled against the ceiling.
This bracket will hold the duct cover in place atthe top.
Secure the bracket to the ceiling and wall:
• Align the marked centerline on the bracket with the
centerline on the wall,
• Mark the 2 screw hole locations in the ceiling,
• Drill 1/8" plot holes in the marked locations.
• If pilot holes do not enter studs, enlarge the holes
to 3/8" and install wall fastener anchors.
• Drive screws, by hand, into the fasteners to allow
anchors to expand. Remove the screws.
• Secure the bracket to the ceiling and wall with
wood screws and/or fasteners,
I
i
10

Installation Instructions
WALL-MOUNTEDINSTALLATION--VENTEDTO THEOUTSIDE
I_ PREPARE THE HOOD
•Remove the hood from the box. Remove packaging
and tape,
_<--- Remove2 side
Y
Electrical j cover screws
panel_- u
• Remove one screw on each side of the cover on the
electrical panel. Lift off the cover and set aside with
screws.
=_-----Junction box
,ii- Inside screw
Secure
electrical panel
with 3 screws
• Stand the electrical panel upright.
• Align the screw holes in the bottom of the panel with
the holes on the base of the hood atthe front side.
• Install 3 screws provided.
• Snap the damper into the Install
exhaust outlet on the top damper
of the hood,
[_ MOUNT THE HOOD
Install a wood screw
on each side of the
mounting frame _
Mounting
bracket
• Lift the hood onto the mounting bracket.
• Check to be sure it is level.
• Install wood screws through the hood and into the
wall on each side of the mounting bracket,
Install bottom
mounting
screws
• Extend the canopy forward for better access to the
rear mounting screw holes.
• Install 2 wood screws or fasteners through the
bottom of the hood into the wall,
11

Installation Instructions
WALL-MOUNTEDINSTALLATION--VENTEDTO THEOUTSIDE
[_ CONNECT DUCTWORK
•Install ductwork, making connections in direction of
airflow as illustrated.
• Push duct over the exhaust outlet and damper.
• Secure joints in ductwork with sheetmetal screws.
• Wrap all duct joints with duct tape for an airtight seal.
• Use duct tape to seal the flange connections.
CAUTION: Do not use sheet metal
screws atthe hood flange connection. Doing so
will prevent proper damper operations, Seal
connection with tape only.
Ducttape
over seam
and screw
Air flow
io
PRUDENCE ."
-- Screw
II ne faut pas utiliser de vis autoraurdeuses _ la
connexion du collet de la hotte, Ceci emp_cherait
le bon fonctionnement du registre, N'utiliser que du
ruban adh_sif pour assurer I'_tanch_it_ du raccord.
[] CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING: If house wiring is not 2-wire
with a ground wire, a ground must be provided by the
installer, When house wiring is aluminum, be sure to
use U.L, approved anti-oxidant compound and
aluminum-to-copper connectors.
ADVERTISSEMENT :
Si la maison n'est pas c_blee avec deux fils et un fil
de terre, I'installateur doit installer un fil de terre. Quand
les fils sont en aluminium, il faut prendre soin d'utiliser
des connecteurs aluminium _ cuivre avec une p_te
antioxydante approuv_e par Ui.
• Remove junction box cover and knockout.
• Use a conduit connector to secure the conduit to
the junction box.
• Connect white leads to branch circuit white lead.
• Connect black leads to branch circuit black lead.
• Connect green/yellow leads to branch circuit green
lead or bare ground lead,
• Secure all connections with wire nuts on each
electrical connector.
• Push wires into junction box and replace cover.
Be sure wires are not pinched.
• Secure electrical panel cover with original screws.
12

Installation Instructions
WALL-MOUNTEDINSTALLATION--VENTEDTO THEOUTSIDE
[] INSTALL DUCT COVERS
• Place the decorative duct
covers on top of the hood.
NOTE: The inside (upper)
duct piece has holes on one
end. The holes are intended
for use when the hood is
installed for recirculating
purposes. Slide the vented
end into the outer piece,
the vent holes should not
be visible in this installation.
Mounting,,,_"_ _ ]
screws _ _J
The inside duct piece must slip into the folded ends of
the outer section.
Install 2 screws,
duct cover and
into ceiling
bracket
Insta
2 bottom
duct cover
screws
• Extend the inner duct upwards to the ceiling bracket.
• Secure duct cover to ceiling bracket with 2 screws.
• Secure the lower duct cover to the hood by
installing 2 screws from the bottom of the hood
into the duct cover.
[_ INSTALL FILTERS
• Remove protective film on the filters.
Filter Locks
NOTE:The charcoal filter is not required for this installation.
• Tip the filter into the slots atthe rear of the opening,
Lift the filter lock and pull forward until the filter
rests in the slots.
• Install both metal grease filters.
• To remove the filters, press inwards on the handle
and pull the filter downwards.
[_ FINALIZE INSTALLATION
• Remove all packaging materials.
• Refer to the Owner's Manual for operating
instructions.
13

Installation Instructions
WALL-MOUNTED INSTALLATION--RECIRCU LATING
DUCTWORK, WIRING LOCATIONS
•Determine the exact location of the vent hood,
• Locate the template packed with the literature.
• Measure 36" from the floor to the top of the cooking
surface. Add hood installation height determined on
page 7.Markthat location.
_-Ceiling
<REAR WAL! TEMPLATE
...... ! .......
Au_ BOSOMEDgEWITH
PENCILUNEINDICATI_
BOTTO_E H_D
• Tape the template in position along the penciled line,
CHECKTO BE SURETHE TEMPLATEIS LEVEL.
• Use a level to draw a line straight up,from the centerline
on the template to the ceiling,
HOUSEWIRING LOCATION:
• The junction box is located on the top right side of the
hood.
• Wiring should enter the back wall 20" to 26" above the
bottom of the hood, and within 4" of the right side of the
centerline.
[_ INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT:Framing mustbe capable of
supporting100Ibs.
J
View from rear
cleats
1"x 6" rain.
mounting
__@po rt
Centerline of
installation
space
If drywall is present, markthe screw hole locations for
the top mounting brackets. Remove the template.
• Cut away enough drywall to expose 2vertical studs at
the bracket location indicated on the template.
• Install a horizontal support at least 1" x 6" between
two wall studs at the top bracket installation location.
The horizontalsupportmust beflushwith the room
side ofthe studs.Usecleats behind both sides ofthe
support to secure to wall studs.
• Reinstall drywall.
14

Installation Instructions
WALL-MOUNTED INSTALLATION--RECIRCU LATING
I_ INSTALL MOUNTING BRACKET
This vent hood must be secured to the horizontal
support or wall studs.
•With the template taped in place, use a punch to
mark all mounting screw locations.
• Drill 1/8" pilot holes atthe 6 punched locations.
• Remove the template.
• The 2 holes in the support bracket holes must enter
studs or the horizontal support,
• Use wood screws to secure the mounting bracket to
the wall. The screws must engage wall studs or the
installed horizontal mounting support.
• Check to be sure that the bracket is level.
There is no way to level the hood after hanging
it from this bracket,
I_ PREPARE THE HOOD
• Remove the hood from the box. Remove packaging
and tape.
ElectriCalp_ j,_ _e---- Remove2 side
_ariel cover screws
IJ
• Remove one screw on each side of the cover on the
electrical panel. Lift off the cover and set aside with
screws.
7Junction box
Inside screw
Secure
electrical panel
with 3 screws
• Stand the electrical panel upright.
• Align the screw holes in the bottom of the panel with
the holes on the base of the hood at the front side.
• Install 3 screws provided.
• Snap the damper into the
exhaust outlet on the top of Install
the hood, damper
/
15

Installation Instructions
WALL-MOUNTED INSTALLATION--RECIRCU LATING
[_ MOUNT THE HOOD
Install a wood screw
on each side ofthe
mounting frame
Mounting
bracket
•Liftthe hood onto the mounting bracket,
• Check to be sure it is level.
• Install wood screws through the hood and into the
wall on each side of the mounting bracket,
Install bottom
mounting
screws
• Extend the canopy forward for better access to the
rear mounting screw holes.
• Install 2 wood screws or fasteners through the
bottom of the hood into the wall.
[_ SIZE AND CUT DUCT PIECE
• Hold upper air deflector with
duct connector against the
ceiling,
• Measure from the bottom of
the air deflector to the top of
the hood as shown. Reduce
that dimension by 1" to
facilitate installation,
The duct will cover
and overlap the
deflector and the Measure
hood outlets, length
[_ SIZE AND CUT DUCT PIECE
(cont.)
• Place the assembly over
the hood outlet,
• Cut the duct piece to size and
slip onto the bottom of the duct
connector.
• Use duct tape to seal and secure
the duct piece to the connector.
• Hold the assembly against
the ceiling. The penciled
centerline should show
through the slot in the
deflector. Mark the screw
holes on the sides of the
assembly.
• Remove the assembly and
drill 1/8" pilot holes into
the wall studs.
• Enlarge holes that did not enter studs to 3/8" and
tap plastic or metal anchors into the holes, flush
with the wall.
• Mount the assembly onto the hood outlet, push up
against the ceiling and install the screws provided,
CAUTION: Donotusesheetmetalscrews
atthe hood flange connection. Doing so will prevent
proper damper operations. Seal connection with
tape only,
ATTENTION : N'utilisez pas de
vis autotaraudeuses pour connecter le rabat de
la hotte, En utilisant des vis, vous emp_chez le
bon fonctionnement du volet de fermeture. Scellez
la connection uniquement avec du ruban adh_sif.
16

Installation Instructions
WALL-MOUNTED INSTALLATION--RECIRCU LATING
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING: If house wiring is not 2-wire
with a ground wire, a ground must be provided by
the installer. When house wiring is aluminum, be sure
to use U.L. approved anti-oxidant compound and
aluminum-to-copper connectors.
ADVERTISSEMENT
Si la maison n'est pas c_blee avec deux fils et un fil
de terre, I'installateur doit installer un fil de terre. Quand
les fils sont en aluminium, il faut prendre soin d'utiliser
des connecteurs aluminium _ cuivre avec une p_te
antioxydante approuv_e par U.L.
•Remove junction box cover and knockout.
• Use a conduit connector to secure the conduit to
the junction box.
•Connect white leads to branch circuit white lead.
•Connect black leads to branch circuit black lead.
•Connect green/yellow leads to branch circuit green
lead or bare ground lead.
•Secure all connections with wire nuts on each
electrical connector.
• Push wires into junction box and replace cover.
Be sure wires are not pinched.
• Secure electrical panel cover with original screws.
INSTALL DUCT COVERS
•Place the decorative duct
covers on top of the hood.
NOTE: The inside piece has
holes on one end intended for
use when the hood is installed
for recirculating purposes.
Be sure the vented end is at
the top, the vent holes will
be visible in this installation.
The inside duct piece must slip
into the folded ends on the outer
section.
Mounting
screw holes
vent Install 2 screws,
duct cover and
into ceiling
bracket
Install
2 bottom
duct cover
screws
• Extend the inner duct piece upwards to the ceiling
mounted air deflector.
• Secure the duct cover to the air deflector, driving one
screw on each side.
•Locate the screw holes on the bottom outside edge
of the hood.
•Secure the lower duct cover to the hood by installing
2 screws from the bottom of the hood into the duct
cover.
17

Installation Instructions
WALL-MOUNTED INSTALLATION--RECIRCU LATING
[] INSTALL FILTERS
Charcoal filter
•Remove protective film on the filters.
• Install the black charcoal filter into the center
opening,
Metal grease filters
• -5p filters into the slots at the rear of the opening.
Lift the filter lock and pull forward until the filter
rests in the slots.
Filter Locks
• Install both metal grease filters.
• To remove the filters, press inwards on the handle
and pull the filter downwards.
[_ FINALIZE INSTALLATION
• Remove all packaging materials.
• Refer to the Owner's Manual for operating
instructions.
18

Installation Instructions
UNDER-CABINET INSTALLATION
CABINET REQUIREMENTS
This hood may be installed beneath a wall-mounted
cabinet.
• If the cabinet has been installed, it must be removed
so that wall framing supports can be added.
The cabinet must be at least 20" high between the
bottom frame and the inside top. If the cabinet is not
20" from bottom to inside top, a custom cabinet or
modifications to a different size cabinet and/or soffit
may be required to accommodate the hood housing.
• The cabinet must be 36" wide and at least 12" deep.
• The cabinet must be firmly secured to wall studs or
the added framing support and capable of supporting
100pounds.
19-1/2"
10-3/4"
I
'- 11-3/4"
19
DUCTWORK, WIRING
• Determine the exact location of the vent hood,
• Locate the RearWall Template packed with the
literature.
• Measure 36" from the floor to the top of the cooking
surface. Add the pre-determined hood installation
height. Mark that location.
• Use a level to draw a straight pencil line on the wall.
C5"-3-3/4" centerline
to wall
:eiling
Topframe mounting
screw locations
i
REAR WAL! TEMPLATE
i
• Tape the template in position along the penciled line.
Check to be sure the template is level.
• Use the level to draw a line straight up,from the
centerline on the template to the ceiling,
• Measure 3-3/4" from the back wall to the centerline of
a 6-1/2" hole on the ceiling,
NOTE:If drywall is not present, add drywall thickness to
the 3-3/4" dimension.
HOUSE WIRING LOCATION:
• Thejunction box is located on the top right side of the
hood,
• Wiring should enter the back wall 20" to 26" above the
bottom of the hood, and within 4" of the right side ofthe
centerline. Wiring should enter at least 4" above the
right side of the frame.

Installation Instructions
UNDER-CABINET INSTALLATION
[] INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT: Framingmustbe capable of
supporting100Ibs.
View from rear
cleats
1"x 6" rain.
mounting
support
/
Centerline of
installation
space
/
If drywall is present, mark the screw hole locations for
the top mounting brackets. Remove the template.
• Cut away enough drywall to expose 2vertical studs at
the bracket location indicated on the template.
• Install a horizontal support at least 1" x 6" between
two wall studs atthe top bracket installation location,
The horizontalsupportmustbe flushwith the room
side ofthe studs.Use cleats behind both sides of the
support to secure to wall studs.
• Reinstall drywall.
[] PREPARE THE HOOD
• Remove the hood from the box. Remove packaging
and tape.
--_" _rl'<----Remove 2 side
Electrical cover screws
panel/
• Remove one screw on each side of the cover on
the electrical panel. Lift off the cover and set aside
with screws,
........_,...___Junctionbox
Inside screw
Secure
electrical panel
with 3 screws
• Stand the electrical panel upright.
• Align the screw holes in the bottom of the panel with
the holes on the base of the hood at the front side.
• Install 3 screws provided.
• Snap the damper into the
exhaust outlet on the top of
the hood,
Install
damper
/
20
Other manuals for Monogram ZV800
4
Table of contents
Other GE Ventilation Hood manuals

GE
GE PVX7360 Original instructions

GE
GE Monogram ZV925 User manual

GE
GE PVB98DTBB Manual

GE
GE PVWC924 Operating instructions

GE
GE UVC9420 Original instructions

GE
GE Monogram ZV750 User manual

GE
GE PVB94STSS Manual

GE
GE Monogram ZV42I User manual

GE
GE JVB36 User manual

GE
GE Appliances JVE40 Operating instructions

GE
GE Monogram ZV30H User manual

GE
GE JV650 User manual

GE
GE GE Profile PVB94SN Manual

GE
GE JVB94SHSS User guide

GE
GE Monogram ZV950 User manual

GE
GE GE Monogram ZVC30 User manual

GE
GE JVB37 Original instructions

GE
GE JVB94 Operating instructions

GE
GE Profile JVB37HBB User manual

GE
GE Monogram ZV900 User manual