Listed by 
Underwriters 
Laboratories
For answers to your Monogram,® GE Profile™or 
GE®appliance questions, visit our website at 
ge.com or call GE Answer Center®service, 
800.626.2000.
Alcove or Closet Installation: 
• If your dryer is approved for installation in an alcove or closet, it will be 
stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other 
surfaces are: 0" either side, 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and must contain a 
minimum of 60 sq. in. of open area equally distributed. If this closet contains 
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of 
open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with 
a gas dryer.
Bathroom or Bedroom Installation: 
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of 
local codes, with the National Fuel Gas Code, ANSI Z223.
Minimum Clearance other than Alcove or Closet Installations: 
• Minimum clearances to combustible surfaces 0" both sides, 3" rear.
For more information on venting kits and accessories, 
please call 1-800-GE-CARES.
Stacked Dimensions (in inches) 
Pedestal Dimensions (in inches) 
SBSD137HWW - white
This optional 13" pedestal raises 
the door opening and height of 
the washer or dryer. Feet on 
13" pedestal allow it to adjust to 
13-3/8" height.