GEM PBA-860 User manual

PBA-860 Micro Switch Bar
Magnet Lock Door Loop
PBA-860
Connect to the request-to-exit contact
N.C.
Com.
N.O.
N.C.
Com.
N.O.
Power
Supply
EM
Lock
(fail-safe)
Fig.A
Directly control the fail-safe magnet lock
Time delay or access
control request to exit
N.C.
Com.
N.O.
N.C.
Com.
N.O.
N.C.
Com.
N.O.
Com.
N.O.
Power
Supply
Time
delay
relay
EM
Lock
(fail-safe)
The PBA-860 Mechanical Micro Switch Bar is focus on emergency exit doors (or other large-scale
type doors) , with a pressure push immediately cut the interior micro switch unlocking the
electromagnet lock or other similar devices.
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-PBA860 Ver. H Publish:2010.12.15
N.C.
Com.
N.O.
N.C.
Com.
N.O.
Double pole
micro sw itch output
875
835
60
875(L)*66(W)*61.5mm(D)
Finish: Clear anodized
Switch rated 5 Amp/125VAC
Fig.B
Switch 2 output
(Switch 1 output)
START
Red (N/C)
Black (COM.)
White (N/O)
RESET contact
Adjustable delay timer (1-30 SECONDS)
95db Sounder
RESET
RESET
N.C.
COM.
N.O.
CUT INPUT
CUT INPUT
out-
out+
RELAY
V-
V+
30 1
Power input
Power output
GEM
Electromagneti c lock
(Fail-s afe )
J1 Set contact time for triggering
J2
N.C. / N.O. trigger selectable
Key switch
J3
N.C. / N.O. trigger selectable
for emergency condition
N.O. Tigger
N.C. Tigger
N.O.Tigger
N.C.Tigger
3 seconds constant contacting
(Power)
( )Buzzer
Buzzer
signal output
Signal input for emergency
OUT +/- (Over pass timer
setting prior to cut out power
instantly for emergency
condition)
0.5 second
Manual Instructions
* J1,J2 setting for trigger N.O. or N.C. contact and timer adjustable.
* OUT +/- voltage output eliminated after 1~30 seconds delay timer set, an over pass timer setting OUT +/- prior to cut out power
instantly when emergency (CUT INPUT) condition.
* J3 setting for trigger N.C. or N.O. contact on emergency condition.
* Buzzer and signal output for termination control purpose, contact rated 1.0 Amp.
* Reset Setting to RESET the control system.
* Electromagnet lock is fail-safe version, recommend to use UL approved power supply unit for UPS (Uninterruption Power Supply)
system integration at any time.
* Current rating of 1.25Amp.
* Any accessory that is powered from the out-,out+ has to be able to operate at a minimum voltage of 8.5VDC.
Power supply
PBA-860TDI Micro Switch Bar
The PBA-860TDI Mechanical Micro Switch Bar is focus on emergency exit doors (or other large-scale
type doors) , with a pressure push immediately to cut the interior of micro switch unlocking the
wlwctromagnet lock or other similar devices. Available in 36 “ Standard Sizes in Satin Silver , Red and
Green for versatile applications.
PBA-860TDI control panel wiring diagram
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-PBA860 Ver. H Publish:2010.12.15

This manual suits for next models

1

Other GEM Accessories manuals

GEM GEM KT-10 User manual

GEM

GEM GEM KT-10 User manual

GEM GEM IP67 User manual

GEM

GEM GEM IP67 User manual

GEM 127 Series User manual

GEM

GEM 127 Series User manual

GEM GD-900 User manual

GEM

GEM GD-900 User manual

GEM 4232 User manual

GEM

GEM 4232 User manual

GEM PBT-020-4 User manual

GEM

GEM PBT-020-4 User manual

GEM LHS-50 User manual

GEM

GEM LHS-50 User manual

GEM PBT-010 User manual

GEM

GEM PBT-010 User manual

GEM PBT-020B-2 User manual

GEM

GEM PBT-020B-2 User manual

GEM RTS-500 User manual

GEM

GEM RTS-500 User manual

GEM 2026 Assembly instructions

GEM

GEM 2026 Assembly instructions

GEM LHS-50LH User manual

GEM

GEM LHS-50LH User manual

GEM 4242 User manual

GEM

GEM 4242 User manual

GEM PBT-211UK User manual

GEM

GEM PBT-211UK User manual

GEM 127 Series User manual

GEM

GEM 127 Series User manual

Popular Accessories manuals by other brands

Netvue Belle quick guide

Netvue

Netvue Belle quick guide

Stobag TP7100 manual

Stobag

Stobag TP7100 manual

Alesis AcousticLink quick start guide

Alesis

Alesis AcousticLink quick start guide

Hubbell Direct Drive Electric Cable Reels MMD32 Installation and maintenance instructions

Hubbell

Hubbell Direct Drive Electric Cable Reels MMD32 Installation and maintenance instructions

Honeywell SiXCT Quick installation guide

Honeywell

Honeywell SiXCT Quick installation guide

KIT PWRP2BKNK user manual

KIT

KIT PWRP2BKNK user manual

Konifera BW13000LED instruction manual

Konifera

Konifera BW13000LED instruction manual

SCORPION ERS WATCH DISPLAY instructions

SCORPION

SCORPION ERS WATCH DISPLAY instructions

Monitor TrueCap MK-2 Installation & operation

Monitor

Monitor TrueCap MK-2 Installation & operation

arpal GULF SUPERNOVA SN35 PRODUCT GUIDANCE SHEET

arpal GULF

arpal GULF SUPERNOVA SN35 PRODUCT GUIDANCE SHEET

Lexing LX16C Instruction

Lexing

Lexing LX16C Instruction

Bungard sprint 3000 manual

Bungard

Bungard sprint 3000 manual

Samsung SIS-0001 user manual

Samsung

Samsung SIS-0001 user manual

Safeguard Supply ERA-PRXPG owner's manual

Safeguard Supply

Safeguard Supply ERA-PRXPG owner's manual

WeighTech MicroWeigh Standard Checkweigher product manual

WeighTech

WeighTech MicroWeigh Standard Checkweigher product manual

NeuLog NUL-202 Guide

NeuLog

NeuLog NUL-202 Guide

PCB Piezotronics 352M208 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 352M208 Installation and operating manual

Gira 0384 00 operating instructions

Gira

Gira 0384 00 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.