NAPCO’s Gemini™ GEM-P3200 a popular,
all-around 8 zone hybrid control expandable
to 32 zones or 48 wireless points.
P3200
Gemini
Gemini
•K1CA
•K2AS
•K3DGTL
•K4RF
•K4
•RP1CAe2
•RP2ASe2
•RP3DGTL
RP8LCD
RP8/K800
GEMP3200
Gemini keypads compatible with the GEMP3200
Control panel features
• 8 End-of-line-resistor burglary zones program-
mable for area, exit/entry delay, interior, follower,
day zone, chime, fire options, sensor watch,
swinger shutdown, zone anding and a variety of
other features
• Up to 48 points of up to 32 zones with optional
zone-expansion modules 4- zone keypad EZMs
(built-in)
• Including up to 2 2-wire fire zones
• Up to 32 individually coded users, each with a
programmable authority level
• 3 on-board relay outputs, expandable 24 external
relay outputs
• 3 keypad panics: fire, police & auxiliary
• 2 independent area partitions
• Up to 7 separate access stations by up to 32 users
• Up to 24 separately-addressable X-10 devices with
the GEM-X10KIT
• English-language prompts & system status mes-
sages from choice of keypad (8) models
• User-customized zone descriptions, reprogram-
mable as required
• 2-wire and 4-wire smoke detectors
• Reports alarms, restores and troubles by zone
• 255 event schedule
• 800 event log
• Overview mode permits monitoring and control of
total system from one keypad
• 2 programmable entry delay times
• Interior-bypass group
• Dynamic battery test interrupts charging and
places battery under load every four hours
• Chime by zone; programmable duration
• Non-volatile RAM retains memory during power
losses
• Quickloader™ programmable
• Auto-Download Log
• Exclusive V.A.L.I.D.™ feature (Verifying Automatic
Line Integrity Diagnostic) reduces false alarms due
to changes in line resistance
Communicator features
• Compatible with all major receiver formats,
including BFSK, 4/2, Modem 2, SIA, 4/3/1, 4 + 2
Express and Point ID
• Rotary dial and TouchTone™ with Rotary backup
• 3 20-digit telephone numbers
• Backup reporting, double reporting; split reporting
• 32 User codes with opening/closing reporting by
user
• AC failure reporting with programmable report
delay
• Supervised telephone line cut with programmable
delay
• Pager capability
Specifications
• Operating temperature: 0-49ºC (32-120ºF)
•
Input power: 16.5Vac via Class 2 Plug-In
40VA transformer
•
Loop voltage: 10-13Vdc
•
Loop current:2.5mA with 2.2ohm end-of-line
resistor (model EOL2.2K); 5mA for 2-wire
smoke-detector zones
•
Loop resistance: 300W max.; 50W for 2-wire
smoke detector zones
•
Relay outputs (burglary; reset; aux): wet,
12Vdc, 1.2A max.; dry (cut related jumper for
dry contacts), SPDT contacts 24Vdc, 2A, 0:
6 PF
•
Auxiliary power output: 12Vdc regulated
•
Remote power output: 12Vdc regulated (for
keypads)
•
650 mA combined standby current (remote
power + aux. power + reset relay power)
•
Standby time: residential fire/burglary & com-
mercial burglary, 4 hours min.
•
EZM module: GEM-EZM8: Input, 50mA
(including PGM output. PGM output: 5mA,
12V special application
•
Keypad current: GEM-RP1CAe2: 100mA;
35mA if backlighting is disabled (cut W1,
W2 & W3) PGM Output: 5mA, 12V special
application
•
Maximum number of keypads: 7. Maximum
wiring length for each run (#22AWG): 1000’
divided by total number of keypads & EZMs
on run
•
Designer keypad dimensions: 4 3/8” x 5 7/8”
x 1 1/6” (HWD); 11.1cm x 14.9cm x 2.7cm
(HWD)
Optional Accessories And Peripherals
•
GEM-EVA: electronic voice annunciator -
unique consumer aid.”Talks” users through
system operation
•
VERI-PHONE: Two-way voice/listen-in module
•
WIZARD IIe: Talking alarm/appliance remote
controller works through any touch-tone
phone
•
GEM-RECV8: Wireless receiver, 8 points
•
GEM-RECV16: Wireless receiver, 16 points
•
GEM-RECV96: Wireless receiver, 96 points
•
GEM-TRANS2: Window/door transmitter,
2-point
•
GEM-KEYF: Keyfob transmitter
•
GEM-SMK: Wireless smoke detector
•
GEM-PIR: Wireless PIR, 50x50’
•
GEM-PIRPET
•
GEM-RTRANS
•
GEM-DT: Wireless Adaptive® Dual
Technology sensor, 40x40’
•
GEM-GB: Wireless glass break detector
•
GEM-WP PANIC: Waterproof panic button/
pendant
•
RM3008: Relay module
•
M278: Line-reversal module
•
PS3002: Power-supply module, 13.2Vdc,
1.9A
•
EOL130: 2-wire fire zone resistor, 130ohm,
3ohm
•
EOL2.2K: End-of-line resistor assembly,
2.2ohm for fire circuit
•
FT2200: End-of-line relay/resistor supervisory
module
•
RB1000: Relay board
•
RBAT4: Rechargeable battery, 12Vdc, 4AH
•
RBATH1: Dual battery harness
•
RPB-3: Universal junction box
•
TRF11: Transformer, 16Vac/40VA, Class 2
•
WL1: Wire assembly with lug connector
•
PCD3000: Downloading software for IBM PC-
compatible
•
PC12000/3000: Software with interface for
IBM-compatible computer
•
PCI-MINI: Notebook computer interface
•
OI163: Instruction manual
•
WI818: Programming manual
Gemini™ P3200 zone hybrid control
333 Bayview Avenue, Amityville, New York 11701 USA • 1-800-645-9445• www.napcosecurity.com
Gemini, Wizard, Adaptive and EVA are trademarks of Napco.
A401B
GEMK1CA
4 built in zones
GEMK2AS GEMK3DGTL GEMK4/K4RF
RP1CAe2
4 built in zones
GEMRP2ASe2 GEMRP3DGTL
Compatible with these standard Gemini keypads
ORDERING INFORMATION
• GEM-P3200: Hybrid control panel &
transformer
• GEM-P3200M: Mercantile version of above
•
GEM-EZM8: 8-zone expansion zone module

Other manuals for Gemini GEM-P3200

1

This manual suits for next models

3

Other Gemini Control Panel manuals

Gemini GEM-P816 User manual

Gemini

Gemini GEM-P816 User manual

Gemini GEM-P816 User manual

Gemini

Gemini GEM-P816 User manual

Gemini GEM-P9600 Installation manual

Gemini

Gemini GEM-P9600 Installation manual

Gemini GEM-P9600 User guide

Gemini

Gemini GEM-P9600 User guide

Gemini Gemini GEM-P1664 User manual

Gemini

Gemini Gemini GEM-P1664 User manual

Gemini GEM-P801 User manual

Gemini

Gemini GEM-P801 User manual

Gemini X 255 - User manual

Gemini

Gemini X 255 - User manual

Gemini Gemini GEM-P3200 Installation manual

Gemini

Gemini Gemini GEM-P3200 Installation manual

Gemini P 1632 User manual

Gemini

Gemini P 1632 User manual

Popular Control Panel manuals by other brands

Vallox Exxeo manual

Vallox

Vallox Exxeo manual

Maxsys PC4020 installation manual

Maxsys

Maxsys PC4020 installation manual

Securimax Smart-Vent user guide

Securimax

Securimax Smart-Vent user guide

Acson SLM9 Operation manual

Acson

Acson SLM9 Operation manual

JCM GAMMA VERSUS Series manual

JCM

JCM GAMMA VERSUS Series manual

Siemens FC361 Series Technical manual

Siemens

Siemens FC361 Series Technical manual

Beckhoff CP2912 Installation and operating instructions

Beckhoff

Beckhoff CP2912 Installation and operating instructions

Beckhoff CP39 Series manual

Beckhoff

Beckhoff CP39 Series manual

AEG S 64.92L Instructions for use

AEG

AEG S 64.92L Instructions for use

NAPCO Continental Access Accelaterm Installation and service manual

NAPCO

NAPCO Continental Access Accelaterm Installation and service manual

Elko RF Touch-B user manual

Elko

Elko RF Touch-B user manual

Honeywell FCI Gamewell Flex 404 instruction manual

Honeywell

Honeywell FCI Gamewell Flex 404 instruction manual

Panasonic AK-HRP1005G operating guide

Panasonic

Panasonic AK-HRP1005G operating guide

EBS AVA PRO CPX300W Assembly instructions

EBS

EBS AVA PRO CPX300W Assembly instructions

S&G SG-0007C user manual

S&G

S&G SG-0007C user manual

DSC PowerSeries Neo installation instructions

DSC

DSC PowerSeries Neo installation instructions

Balboa Water Group BP Series User Interface and Programming Reference Manual

Balboa Water Group

Balboa Water Group BP Series User Interface and Programming Reference Manual

Jung Smart Control 8 operating instructions

Jung

Jung Smart Control 8 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.