manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Gemini
  6. •
  7. Control Panel
  8. •
  9. Gemini Gemini GEM-P3200 User manual

Gemini Gemini GEM-P3200 User manual

NAPCO’s Gemini™ GEM-P3200 a popular,
all-around 8 zone hybrid control expandable
to 32 zones or 48 wireless points.
P3200
Gemini
Gemini
•K1CA
•K2AS
•K3DGTL
•K4RF
•K4
•RP1CAe2
•RP2ASe2
•RP3DGTL
RP8LCD
RP8/K800
GEMP3200
Gemini keypads compatible with the GEMP3200
Control panel features
• 8 End-of-line-resistor burglary zones program-
mable for area, exit/entry delay, interior, follower,
day zone, chime, fire options, sensor watch,
swinger shutdown, zone anding and a variety of
other features
• Up to 48 points of up to 32 zones with optional
zone-expansion modules 4- zone keypad EZMs
(built-in)
• Including up to 2 2-wire fire zones
• Up to 32 individually coded users, each with a
programmable authority level
• 3 on-board relay outputs, expandable 24 external
relay outputs
• 3 keypad panics: fire, police & auxiliary
• 2 independent area partitions
• Up to 7 separate access stations by up to 32 users
• Up to 24 separately-addressable X-10 devices with
the GEM-X10KIT
• English-language prompts & system status mes-
sages from choice of keypad (8) models
• User-customized zone descriptions, reprogram-
mable as required
• 2-wire and 4-wire smoke detectors
• Reports alarms, restores and troubles by zone
• 255 event schedule
• 800 event log
• Overview mode permits monitoring and control of
total system from one keypad
• 2 programmable entry delay times
• Interior-bypass group
• Dynamic battery test interrupts charging and
places battery under load every four hours
• Chime by zone; programmable duration
• Non-volatile RAM retains memory during power
losses
• Quickloader™ programmable
• Auto-Download Log
• Exclusive V.A.L.I.D.™ feature (Verifying Automatic
Line Integrity Diagnostic) reduces false alarms due
to changes in line resistance
Communicator features
• Compatible with all major receiver formats,
including BFSK, 4/2, Modem 2, SIA, 4/3/1, 4 + 2
Express and Point ID
• Rotary dial and TouchTone™ with Rotary backup
• 3 20-digit telephone numbers
• Backup reporting, double reporting; split reporting
• 32 User codes with opening/closing reporting by
user
• AC failure reporting with programmable report
delay
• Supervised telephone line cut with programmable
delay
• Pager capability
Specifications
• Operating temperature: 0-49ºC (32-120ºF)
•
Input power: 16.5Vac via Class 2 Plug-In
40VA transformer
•
Loop voltage: 10-13Vdc
•
Loop current:2.5mA with 2.2ohm end-of-line
resistor (model EOL2.2K); 5mA for 2-wire
smoke-detector zones
•
Loop resistance: 300W max.; 50W for 2-wire
smoke detector zones
•
Relay outputs (burglary; reset; aux): wet,
12Vdc, 1.2A max.; dry (cut related jumper for
dry contacts), SPDT contacts 24Vdc, 2A, 0:
6 PF
•
Auxiliary power output: 12Vdc regulated
•
Remote power output: 12Vdc regulated (for
keypads)
•
650 mA combined standby current (remote
power + aux. power + reset relay power)
•
Standby time: residential fire/burglary & com-
mercial burglary, 4 hours min.
•
EZM module: GEM-EZM8: Input, 50mA
(including PGM output. PGM output: 5mA,
12V special application
•
Keypad current: GEM-RP1CAe2: 100mA;
35mA if backlighting is disabled (cut W1,
W2 & W3) PGM Output: 5mA, 12V special
application
•
Maximum number of keypads: 7. Maximum
wiring length for each run (#22AWG): 1000’
divided by total number of keypads & EZMs
on run
•
Designer keypad dimensions: 4 3/8” x 5 7/8”
x 1 1/6” (HWD); 11.1cm x 14.9cm x 2.7cm
(HWD)
Optional Accessories And Peripherals
•
GEM-EVA: electronic voice annunciator -
unique consumer aid.”Talks” users through
system operation
•
VERI-PHONE: Two-way voice/listen-in module
•
WIZARD IIe: Talking alarm/appliance remote
controller works through any touch-tone
phone
•
GEM-RECV8: Wireless receiver, 8 points
•
GEM-RECV16: Wireless receiver, 16 points
•
GEM-RECV96: Wireless receiver, 96 points
•
GEM-TRANS2: Window/door transmitter,
2-point
•
GEM-KEYF: Keyfob transmitter
•
GEM-SMK: Wireless smoke detector
•
GEM-PIR: Wireless PIR, 50x50’
•
GEM-PIRPET
•
GEM-RTRANS
•
GEM-DT: Wireless Adaptive® Dual
Technology sensor, 40x40’
•
GEM-GB: Wireless glass break detector
•
GEM-WP PANIC: Waterproof panic button/
pendant
•
RM3008: Relay module
•
M278: Line-reversal module
•
PS3002: Power-supply module, 13.2Vdc,
1.9A
•
EOL130: 2-wire fire zone resistor, 130ohm,
3ohm
•
EOL2.2K: End-of-line resistor assembly,
2.2ohm for fire circuit
•
FT2200: End-of-line relay/resistor supervisory
module
•
RB1000: Relay board
•
RBAT4: Rechargeable battery, 12Vdc, 4AH
•
RBATH1: Dual battery harness
•
RPB-3: Universal junction box
•
TRF11: Transformer, 16Vac/40VA, Class 2
•
WL1: Wire assembly with lug connector
•
PCD3000: Downloading software for IBM PC-
compatible
•
PC12000/3000: Software with interface for
IBM-compatible computer
•
PCI-MINI: Notebook computer interface
•
OI163: Instruction manual
•
WI818: Programming manual
Gemini™ P3200 zone hybrid control
333 Bayview Avenue, Amityville, New York 11701 USA • 1-800-645-9445• www.napcosecurity.com
Gemini, Wizard, Adaptive and EVA are trademarks of Napco.
A401B
GEMK1CA
4 built in zones
GEMK2AS GEMK3DGTL GEMK4/K4RF
RP1CAe2
4 built in zones
GEMRP2ASe2 GEMRP3DGTL
Compatible with these standard Gemini keypads
ORDERING INFORMATION
• GEM-P3200: Hybrid control panel &
transformer
• GEM-P3200M: Mercantile version of above
•
GEM-EZM8: 8-zone expansion zone module

Other manuals for Gemini GEM-P3200

1

This manual suits for next models

3

Other Gemini Control Panel manuals

Gemini Gemini GEM-P3200 Installation manual

Gemini

Gemini Gemini GEM-P3200 Installation manual

Gemini X 255 - User manual

Gemini

Gemini X 255 - User manual

Gemini GEM-P801 User manual

Gemini

Gemini GEM-P801 User manual

Gemini GEM-P816 User manual

Gemini

Gemini GEM-P816 User manual

Gemini Gemini GEM-P1664 User manual

Gemini

Gemini Gemini GEM-P1664 User manual

Gemini GEM-P9600 User guide

Gemini

Gemini GEM-P9600 User guide

Gemini P 1632 User manual

Gemini

Gemini P 1632 User manual

Gemini GEM-P816 User manual

Gemini

Gemini GEM-P816 User manual

Gemini GEM-P9600 Installation manual

Gemini

Gemini GEM-P9600 Installation manual

Popular Control Panel manuals by other brands

Siemens SXL-EX datasheet

Siemens

Siemens SXL-EX datasheet

Texecom Veritas 8 installation manual

Texecom

Texecom Veritas 8 installation manual

AERMEC FMT 20 AW Use and installation  manual

AERMEC

AERMEC FMT 20 AW Use and installation manual

IFM PDM360NG Series System manual

IFM

IFM PDM360NG Series System manual

Zanussi ZES 2226 Installation and operating instructions

Zanussi

Zanussi ZES 2226 Installation and operating instructions

Viessmann 5546 Operation manual

Viessmann

Viessmann 5546 Operation manual

Pego ECP200 STEPPER user manual

Pego

Pego ECP200 STEPPER user manual

Satel PERFECTA-T Installer manual

Satel

Satel PERFECTA-T Installer manual

Hitachi PC-S80TE installation manual

Hitachi

Hitachi PC-S80TE installation manual

ABB CP430 Installation and operation manual

ABB

ABB CP430 Installation and operation manual

Mircom FX-400 Installation and operation manual

Mircom

Mircom FX-400 Installation and operation manual

Haes Esento Eclipse ECL-2 Installation, commissioning & operating  manual

Haes

Haes Esento Eclipse ECL-2 Installation, commissioning & operating manual

Honeywell MINI-ZONE 69-1361 Schematic diagram

Honeywell

Honeywell MINI-ZONE 69-1361 Schematic diagram

Pego ECP202 EXPERT Use and maintenance manual

Pego

Pego ECP202 EXPERT Use and maintenance manual

Westell VirtualEdge VELGX-30 manual

Westell

Westell VirtualEdge VELGX-30 manual

ADEMCO 6127 quick guide

ADEMCO

ADEMCO 6127 quick guide

NAPCO MFA6000 manual

NAPCO

NAPCO MFA6000 manual

Truma iNet X installation instructions

Truma

Truma iNet X installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.