Gemini X255 is the expansive hardwire/wireless
control offering 255 fully-programmable zones,
195 users, fuseless operation & supports the full
line of top performing Gemini Wireless.
X255
Gemini
Gemini
•K1CA
K2AS
K3DGTL
K4RF
K4
•RP1CAe2
RP2ASe2
RP3DGTL
RP8LCD
RP8/K800
GEMX255
Gemini keypads compatible with the GEMP9600
Manufacturing great security products is all we do. It’s that simple.™
Control panel features
• 8 to 255 zones, hardwire or wireless zones
from GEM EZM8 zone- expansion modules and
RP1/K1 4-zone keypads or wireless points using
Gemini receivers
• Including up to 8 2-wire fire zones
• Up to 195 individually coded users, each with a
programmable authority level
• Exclusive RS232 panel-port supports PC home
automation/ networking integration for 9600
baud comprehensive communications
• Fuseless maintenance-free operation
• 8 End-of-line-resistor burglary zones programma-
ble for area, exit/entry delay, interior, follower, day
zone, chime, fire option, sensor watch, swinger
shutdown, zone anding and a variety of other
features
• 3 on-board relay outputs; expandable to 99
• Three keypad panics: fire, police & auxiliary
• Up to 8 independent area partitions
• Up to 8 separate access stations for up to 195
users
• Up to 64 separately-addressable X-10 devices with
the GEM-X10KIT
• English-language prompts & system status mes-
sages from keypad (GEM-RP1CAe2 installed “with
255 support” only)
• User-customized zone descriptions, reprogram-
mable as required
• Supports 2-wire and 4-wire smoke detectors
• Reports alarms, restores and troubles by zone
• 255 event schedule
• 800 event log
• Overview mode permits monitoring and control of
total system from one keypad
• Supports up to 4 RF receivers
• Guard-tour programmable for start time, tour
length, and check points (tour stations)
• 2 programmable entry delay times
• 2 interior-bypass groups
• Dynamic battery test interrupts charging and plac-
es battery under load every four hours
• Chime by zone; programmable duration
• Non-volatile RAM retains memory during power
losses
• PCD-Windows programmable
• Auto-download log
• Exclusive V.A.L.I.D.™ FEATURE (Verifying
Automatic Line Integrity Diagnostic) reduces false
alarms due to changes in line resistance
Communicator features
• Compatible with all major receiver formats,
including BFSK, 4/2, Modem 2, SIA, 4/3/1, 4 + 2
Express and Point ID
• Rotary dial and TouchTone™ with rotary backup
• 3 20-digit telephone numbers
• Backup reporting; double reporting; split reporting
• 195 User codes with opening/closing reporting
by user
• AC failure reporting with programmable report
delay
• Supervised telephone line cut with programmable
delay
• Pager capability
Specifications
Operating temperature: 0-49ºC (32-120ºF)
Input power: 16.5Vac via Class 2 Plug-In 40VA
Transformer, supplied
Loop voltage: 10-13VAC
Loop current: 2.5mA with 2.2ohm end-of-line resis-
tor (model EOL2.2K); 5mA for 2-wire smoke-detec-
tor zones
Loop resistance: 300W max.; 50W for 2-wire smoke
detector zones
Relay outputs (burglary; reset; aux): wet, 12Vdc,
1.2A max.; dry (cut related jumper for dry contacts),
SPDT contacts 24Vdc, 2A
Auxiliary power output: 12 Vdc regulated
Remote power output: 12Vdc regulated (for key-
pads) 750 mA combined Standby Current (Remote
Power + Aux. Power + Reset Relay Power)
Standby time: Residential fire/burglary & commer-
cial burglary, 4 hours minimum
EZM Module: GEM-EZM8: input, 50mA (including
PGM Output) PGM output: 5mA, 12V special appli-
cation
Keypad current:
GEM-RP1CAe2, GEM K1CA: 100mA; 35mA if back
lighting is disabled (cut W1, W2 & W3) PGM output:
5mA, 12V special application
Maximum number of keypads: 15 maximum wir-
ing length for each run (#22AWG): 1000’ divided by
total number of keypads & EZMs on run
Keypad Dimensions: 4 3/8” x 5 7/8” x 1 1/6”
(HWD); 11.1cm x 14.9cm x 2.7cm (HWD)
Optional accessories and peripherals
GEM-EZM8: 8-Zone expansion zone module (see
models labeled “GEM-X255 Support”)
VERI-PHONE: Two-way voice/listen in system
GEM-RECV8: Wireless receiver, 8 points
GEM-RECV16: Wireless receiver, 16 points
GEM-RECV96: Wireless receiver, 96 points
GEM-RECV255: Wireless receiver, 255 points*
GEM-TRANS2: Window/door transmitter, 2-point
GEM-RTRANS: Recessed wireless window/door
transmitter, 1-point
GEM-KEYF: Keyfob transmitter
GEM-SMK: Wireless smoke detector
GEM-PIR: Wireless PIR, 50x50’
GEM-PIRPET: Wireless 40 lb. pet immunity PIR
GEM-DT: Wireless Adaptive® Dual Technology sen-
sor, 40x40’
GEM-GB: Wireless glass break detector
GEM-WP PANIC: Waterproof panic button/pen-
dant
GEM-HEAT: Rate of rise heat detector
2 WAYUNIVKFKIT: 2 Way LCD keyfob &
receiver
Home/facilities automation:
GEM-RS232KIT: Alarm-to-PC interface
for 100% 2-way intercommunications
with a growing number of leading
PC automation software pack-
ages (including, but not limited
to, IBM Home Director™, Savoy
Cyberhouse™, Crestron, Phast,
etc.)
GEM-DEVELOPER: System
development professional’s
protocol for custom program-
ming seamless integration with
Gemini RS232 port communi-
cations.
GEM-X10 Interface Module:
Provides programming &
scheduler-integrated X-10
device support.
RM3008: relay module
M278: Line-reversal module
PS3002: Power-supply module, 13.2Vdc, 1.9A
EOL130: 2-Wire fire zone resistor, 130ohm, 3ohm
EOL2.2K: End-of-line resistor assembly, 2.2ohm for
fire circuit
FT2200: EOL relay/resistor supervisory module
RB1000: Relay board
RBAT4: Rechargeable battery, 12Vdc, 4AH
RBATH1: Dual battery harness
RPB-3: Universal junction box
TRF11: Transformer, 16Vac/40VA, Class 2
WL1: Wire assembly with lug connector
*Consult panel documentation for UL restrictions which may
apply to UL installations using upwards of 200 wireless-only
points
Gemini™ X255 zone hybrid control
In North America 1-800-645-9445 • 631-842-9400
333 Bayview Avenue, Amityville, New York 11701 USA • www.napcosecurity.
com
International 224 Europa Blvd, Gemini Business Park Warrington WA5 7TN
England UK 44 (0) 1925242428
Gemini, Wizard, StarLink, Adaptive and EVA are trademarks of Napco.
A446A
RP1CAe2
4 built in zones
GEMK1CA
4 built in zones
Compatible with these standard Gemini keypads
GEM-TRANS2
WINDOW/DOOR
GEM-PIR/
GEM-PIRPET
PASSIVE
GEM-DT
DUAL
TECHNOLOGY
GEM-GB
ACOUSTIC GLASS
BREAK
GEM-SMK
SMOKE
GEM-HEAT
DETECTOR
GEM-WPPANIC
WATERPROOF
PANIC
GEM-RTRANS
RECESSED
WINDOW DOOR
Ordering information
• GEM-X255: Super Expandable Hybrid Control
Panel & Transformer
• GEM-RP1CAe2: 32-Character EZ-Read Backlit
LCD Keypad with 4 EOL Zone Expansion
Module built-in (See models labeled “GEM-
X255 Support”!)
• GEMK1CA: Keypad same as above with Stay &
Away functions.
• StarLink SL-1: Backup wireless receiver for all
alarm panel brands
• NAPCO NETLINK™ Intranet/Internet Alarm
Reporting Components (for specs see website ,
or literature # A482).
• GeminiAccess™ economically add up to 8
doors of access control to Gemini Panels.
Several paks are available (for specs see
website, or literature #A481).
Use with the
full Gemini
crystal-control
wireless line,
proven in
independent
tests to
outperform
top
competitive
brands.
GEM-KEYF
KEYFOB

This manual suits for next models

1

Other Gemini Control Panel manuals

Gemini Gemini GEM-P1664 User manual

Gemini

Gemini Gemini GEM-P1664 User manual

Gemini GEM-P9600 User guide

Gemini

Gemini GEM-P9600 User guide

Gemini GEM-P816 User manual

Gemini

Gemini GEM-P816 User manual

Gemini GEM-P816 User manual

Gemini

Gemini GEM-P816 User manual

Gemini GEM-P9600 Installation manual

Gemini

Gemini GEM-P9600 Installation manual

Gemini GEM-P801 User manual

Gemini

Gemini GEM-P801 User manual

Gemini Gemini GEM-P3200 Installation manual

Gemini

Gemini Gemini GEM-P3200 Installation manual

Gemini Gemini GEM-P3200 User manual

Gemini

Gemini Gemini GEM-P3200 User manual

Gemini P 1632 User manual

Gemini

Gemini P 1632 User manual

Popular Control Panel manuals by other brands

DMP Electronics XR550 series installation guide

DMP Electronics

DMP Electronics XR550 series installation guide

THG PARIS 6760D installation instructions

THG PARIS

THG PARIS 6760D installation instructions

Tylo Elite Installation guide and quick start guide

Tylo

Tylo Elite Installation guide and quick start guide

Dometic MPC01 Installation and operating manual

Dometic

Dometic MPC01 Installation and operating manual

BLUGUARD SmartBus P900-TI6N user manual

BLUGUARD

BLUGUARD SmartBus P900-TI6N user manual

nilan CTS 602 user manual

nilan

nilan CTS 602 user manual

Interlogix Simon 3 installation instructions

Interlogix

Interlogix Simon 3 installation instructions

Fabman Bridge FB-V2 user manual

Fabman

Fabman Bridge FB-V2 user manual

Casit EQ400I INSTALLER TECHNICAL MANUAL

Casit

Casit EQ400I INSTALLER TECHNICAL MANUAL

AUDAC DW5066/W User manual & installation guide

AUDAC

AUDAC DW5066/W User manual & installation guide

Intermatic T10604R operating instructions

Intermatic

Intermatic T10604R operating instructions

SALUPO EVO 3 MULTI Instruction and installation manual

SALUPO

SALUPO EVO 3 MULTI Instruction and installation manual

Johnson Controls FC-2000 Installing

Johnson Controls

Johnson Controls FC-2000 Installing

Satel Versa Plus Quick user manual

Satel

Satel Versa Plus Quick user manual

Tiandy 5820B Guide

Tiandy

Tiandy 5820B Guide

Johnson Controls FRICK QUANTUM LX AcuAir maintenance

Johnson Controls

Johnson Controls FRICK QUANTUM LX AcuAir maintenance

Woodward easYview Series Technical manual

Woodward

Woodward easYview Series Technical manual

fisair CCB2.0 Installation and operation manual

fisair

fisair CCB2.0 Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.