button for about 3 seconds until CAL displays.
3. Press the CAL button again. The scale should flash “CAL”
a few times and then start flashing 500g on the display.
4. Place a 500g calibration weight on the platform while
being certain the scale is stable and until the display reads
PASS. Calibration is complete. Please contact your scale
supplier to order a 500g calibration weight. Note that 20
US nickels weighs 100g, so in case emergency calibration
is required, the scale may be calibrated with 100 nickels.
PCS (Parts Pieces Counting) Function
To count a quantity of the same item, it is first necessary to
determine the average weight of the items being counted.
The larger the sample size of the item to be counted, the
more accurate the count will be. This feature may be used
for items weighing a minimum of 1 gram each.
1. Turn the scale ON.
2. Press the MODE (M) button to the g or gram mode.
(Please note before proceeding: The scale has sample
sizes of 25, 50, 75 and 100. If you choose to use a sample
size of 25 pieces, those 25 pieces must weigh a total of at
least 25g; a sample size of 50 pieces must weigh a total of
at least 50g, etc.)
3. Place your sample size on the scale platform.
4. Press the PCS button and hold it down until the sample
size of 50 (or your last pcs mode) is displayed. If your
sample size is 25, 75 or 100 pieces, press the MODE (M)