EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. General
  6. •
  7. Measuring Instrument
  8. •
  9. General SAF-T-LITE I.S. 300 Guide

General SAF-T-LITE I.S. 300 Guide

Other General Measuring Instrument manuals

General DSM402SD User manual

General

General DSM402SD User manual

General Mini Airflow DAF3010 User manual

General

General Mini Airflow DAF3010 User manual

General MMD7NP User manual

General

General MMD7NP User manual

General PM930SD User manual

General

General PM930SD User manual

General DCFM700 User manual

General

General DCFM700 User manual

General DTH04 User manual

General

General DTH04 User manual

General CA10 User manual

General

General CA10 User manual

General EP8710 User manual

General

General EP8710 User manual

General DCM7021 User manual

General

General DCM7021 User manual

General DCiS2 iBorescope2 User manual

General

General DCiS2 iBorescope2 User manual

General MMD950 User manual

General

General MMD950 User manual

General MM1E User manual

General

General MM1E User manual

General MSV100 User manual

General

General MSV100 User manual

General MMD7003 User manual

General

General MMD7003 User manual

General LDM60 User manual

General

General LDM60 User manual

General MM70D User manual

General

General MM70D User manual

General PCT2236B User manual

General

General PCT2236B User manual

General SAM990DW User manual

General

General SAM990DW User manual

General TS01 User manual

General

General TS01 User manual

General MMH800 User manual

General

General MMH800 User manual

General MMD900 User manual

General

General MMD900 User manual

General DSM403SD User manual

General

General DSM403SD User manual

General MMD4E User manual

General

General MMD4E User manual

General UV254SD User manual

General

General UV254SD User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

I.S. 300
Intrinsically Safe Task Light
Warranty & Instruction Manual
Care & Operation of your New
Intrinsically Safe Task Light
OPERATION & MAINTENANCE
1. Read the operator’s manual entirely before using the I.S. 300
light.
2. Charge battery as described below
3. After installing fully charged battery in light, you will have 6
hours of continuous use.
4. Battery has an Led Indicator light that will start blinking when
there is approximately 30 minutes until light shuts off. Blinking
feature will slow as the battery reaches shut off point.
5. Light will not come back on until charged. The charge will reset
the circuitry.
6. To adjust light from task light to spot light, push lens in for wide
angle task light or pull lens out for beam spotlight.
7. To Pivot head, loosen clamping knob just enough to pivot
head where desired, then tighten knob.
8. Switch has a momentary mode with an ON mode. This means
you can press the switch lightly for a quick momentary ON or
press the switch until you hear a click to lock in ON position.
9. Long term storage: Fully charge the battery and disconnect it
from the light. Store battery and light separated in a cool dry area.
Make sure to recharge battery every three months if not in use.
10. Caution: If the light is being used in a remote darkened area and
the fuel gauge indicator light begins blinking, we recommend
exiting the darkened area to replace spent battery with a fully
charged battery.
11. Clean the Lens with a damp cloth with mild detergent or
waterless hand cleaners. Take caution not to scratch lens in order
to provide the best light output at all times.
CAUTION
•
DO NOT SHINE LIGHT DIRECTLY INTO EYES.
•
Inspect regularly for damage and repair or replace if necessary.
•
If battery pack is cracked or damaged - do not use - replace
battery pack immediately.
•
Do not submerge in liquids.
•
Do not use charger in Hazardous Atmosphere.
•
Battery pac may be replaced in hazardous atmosphere.
•
Use only Saf-T-Lite replacement battery pack (5000-1344)
•
Use only Saf-T-Lite charger model number (5000-1345)
•
Do not operate light in temperatures exceeding +40C or below
-20C.
•
Dispose of spent battery packs in accordance with local and
Federal laws.
SPECIFICATIONS
•
Unit Weight: 4.15 lbs
•
Dimensions:
Height - 13 1/4”
Width - 4 1/2”
Depth - 6”
•
Light output level - Worklight position @ 5’ XXXCP
•
High beam position @10’ XXXCP
•
Three 3-watt high power LED’s
•
4.8 Volt NiMH Battery Pack
•
Six hour continuous run time
BATTERY CHARGING INSTRUCTIONS
1. DO NOT CHARGE IN HAZARDOUS ATMOSPHERE
2. Plug the AC adaptor into 120 VAC power outlet.
3. Be sure that the selection switch in the top left corner of
charger is set to 1.8A.
4. Plug charger DC jack into top of battery DC jack.
5. LED indicator light on charger will turn Red during charging.
6. Indicator light on charger will turn green when fully charged.
7. When charged, disconnect from AC power outlet.
8. CAUTION: Extensive overcharging will affect the normal per-
formance and service life of the battery.
11” x 17” Trimmed to 8.5” x 16.5” and Tri-Folded
Rated for Hazardous Locations
Class I, Div. 1, Groups C & D
Temperature Code - T3
CONFORMS TO
UL STDS 783 & 913
CERTIFIED TO
CAN/CSA STD C22.2 NO 157-92
4000110
FORM # 9032-7290 (01/10)
1 Year Warranty
This Worklight was thoroughly tested and inspected and found to be in
perfect working order before leaving our factory. If within 1 year from date
of purchase, any part of this unit proves to be defective in material or
workmanship, such defective part will be repaired or replaced (company
option) free of charge. The company’s liability in all events is limited to the
purchase price paid.
The warranty does not apply to the battery, nor does it apply to damage,
alteration, misuse or abuse not attributed to the manufacturer, representa-
tives, dealers or their employees. This warranty does not apply if the
product is mishandled or operated with a battery pack other than one sup-
plied by the manufacturer. This warranty pertains to any Worklight that
may be termed by manufacturers, as a service unit.
Illustrations and descriptions are for the sole purpose of identification and
do not express or imply a warranty that the products will necessarily con-
form to the illustrations or descriptions.
When returning product for warranty repair, please provide: from
whom purchased, date of purchase and attach receipt or give invoice
number.
KEEP THIS MANUAL
If this Worklight malfunctions or is in need of repairs, send to:
CUSTOMER SERVICE DEPARTMENT
1100 SOUTH MORGAN STREET
BLUFFTON, IN 46714
Phone: 260-824-3440 Email: sales@saftlite.com
DO NOT return to place of purchase. They
Are not authorized to accept used or damaged units.
SPECIAL FEATURES
•
Specially compounded rugged material
•
Battery impact protection
•
Ergonomic pistol grip handle
•
Non-sparking rotating metal hook incorporated in rear end cap
to hang unit.
•
Battery fuel gauge indicator light
•
Patented intrinsically safe electrical system
•
Selectable beam or work light setting
•
Soft bumpers for impact protection of light head
•
Light can set on its base or hung by hook
•
Two stage switch (momentary and ON)
•
Specially designed heat sink to ensure long LED life
•
Optional chemical resistant clear lens cover
•
Optional red lens cover for night use
Hazardous Location Listings Explained
Class I - Flammable Gases, Vapors or Liquids
Division 1 - Where ignitable concentrations can exist all
of the time
Groups - C - (ethylene)
D- (propane)
Temperature Code T3 ≤200 C
Intrinsically Safe Light Parts List
Item Part No. Description Item Part No. Description
1 5000-1356 Lens Cover w/chain 6 5000-1349 Handle half w/label
2 5000-1346 Light Head w/conn. & labels 7 5000-1357 Handle screw
3 5000-1355 Hook Assy 8 5000-1344 Battery Pac w/labels
4 5000-1347 Switch Assy with connectors 9 5000-1345 Charger
5 5000-1348 Handle half w/wireway 10 5000-1437 8” Lanyard with ring
3
1
Parts List (continued)
5
9
8
4
3
2
7
6
(4) req’d