GESS ACKP50EM-I User manual

ACKP50EM-I
®
MANUAL ACKP50EM-I
Quantity Remarks
1
1
1 Φ20mm×60mm,Special for keypad
2 Φ6mm×30 mm, used for fixing
2 Φ4mm×28 mm, used for fixing
1 Φ3mm×6mm, used for fixing
1. PACKING LIST
Name
Keypad
User manual
Screw driver
Rubber plug
Self tapping screws
Star screws
Please ensure that all the above contents are correct. If any are missing please notify the supplier of
the unit.

The unit is single door multifunction standalone access controller or a Wiegand output keypad or
card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in
a strong, sturdy and vandal proof Zinc Alloy electroplated case which is available in either a bright
silver or matt silver finish. The electronics are fully potted so the unit is. This unit supports up to 2000
users in either a Card, 4 digit PIN, or a Card + PIN option. The inbuilt card reader supports 125KHZ EM
cards,13.56MHz Mifare cards. The unit has many extra features including lock output current short
circuit protection, Wiegand output , and a backlit keypad. These features make the unit an ideal
choice for door access not only for small shops and domestic households but also for commercial
and industrial applications such as factories, warehouses, laboratories, banks and prisons.
2. QUICK REFERENCE PROGRAMMING GUIDE
3. DESCRIPTION
To enter the programming mode
To exit from the programming mode
To change the master code
To add a PIN user.
To add a card user
To delete a PIN or a card user.
To unlock the door for a PIN user Enter the then press
Present the cardTo unlock the door for a card user
999999 is the default factory master code
The master code can be 6 to 8 digits
for a PIN user or
for a card user
#
Master Code
#
New Code #
New Code
0
#
Read Card
1
#
Read Card
2
#
User ID number #
PIN
PIN
1
#
#
User ID number
2
®
MANUAL ACKP50EM-I
Note that to undertake the following programming the master user must be logged in
The ID number is any number between 1 & 2000. The PIN is
any four digits between 0000 & 9999 with the exception of
1234 which is reserved. Users can be added continuously
without exiting programming mode
Cards can be added continuously without exiting
programming mode
Users can be deleted continuously without exiting
programming mode

Strong Zinc Alloy Electroplated anti-vandal case
Full programming from the keypad
2000 uses, supports Card, PIN, Card + PIN
Can be used as a stand alone keypad
Backlight keys
Wiegand 26 input for connection to external reader
Wiegand 26 output for connection to a controller
Adjustable Door Output time, Alarm time, Door Open time
Very low power consumption (30mA)
Fast operating speed, <20ms with 2000 users
Lock output current short circuit protection
Easy to install and program
Built in light dependent resistor (LDR) for anti tamper
Built in buzzer
Red, Yellow and Green LEDS display the working status
Operating Voltage DC 12V±10%
User Capacity 2000
Card Reading Distance 3-6 cm
Active Current <60mA
Idle Current 25±5 mA
Lock Output Load Max 3A
Alarm Output Load Max 20A
Operating Temperature -45℃〜60℃
Operating Humidity 10%- 90% RH
Adjustable Door Relay time 0 -99 seconds
Adjustable Alarm Time 0- 3 minutes
Wiegand Interface Wiegand 26 bit
Wiring Connections Electric Lock, Exit Button, External Alarm,External reader
5. SPECIFICATIONS
4. FEATURES
®
MANUAL ACKP50EM-I

®
MANUAL ACKP50EM-I
6. INSTALLATION
Remove the back cover from the keypad using the supplied special screw driver
Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
Put the supplied rubber bungs to into the two holes
Fix the back cover firmly on the wall with 2 Self tapping screws
Thread the cable through the cable hole
Attach the keypad to the back cover.
Colour Function Description
Pink BELL_A Doorbell button one end
Pale blue BELL_B Doorbell button to the other end
Green D0 WG output D0
White D1 WG output D1
Grey ALARM Alarm negative(alarm positive connected 12 V+)
Yellow OPEN Exit button one end(the other end connected GND)
Brown D_IN Magnetic switch one end(the other end connected GND)
Red 12V+ 12V + DC Regulated Power Input
Black GND 12V - DC Regulated Power Input
Blue NO Relay normally-on end(Connect positive electric lock "-")
Purple COM Relay Public end, connect GND
Orange NC Relay Closed end(connect negative electric lock "-")
7. WIRING

®
MANUAL ACKP50EM-I
a. Disconnect power from the unit
b. Press and hold # key whilst powering the unit back up
c. On hearing two “Di” release # key, system is now back factory settings
8. TO RESET TO FACTORY DEFAULT
Common power supply diagram:
Special power supply diagram:

®
MANUAL ACKP50EM-I
Operation Status Red Light Green Light Yellow Light Buzzer
Power on - Bright - Di
Stand by Bright - - -
Press keypad - - - Di
Operation successful - Bright - Di
Operation failed - - - DiDiDi
Enter into programming mode Bright - -
In the programming mode - - Bright Di
Exit from the programming mode Bright - - Di
Open the door - Bright - Di
Alarm Bright - - Alarm
The unit uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is
removed from the cover then the tamper
alarm will operate.
9. ANTI TAMPER ALARM
10.SOUND AND LIGHT INDICATION
11.1 User Settings
To enter the programming mode
Setting the working mode:
Set valid card only users
Set valid card and PIN users
Set valid card or PIN users
Entry is by card only
Entry is by card and PIN together
Entry is by either card or PIN (default)
To exit from the programming mode
To change the master code
999999 is the default factory master code
The master code can be 6 to 8 digits long
#
Master Code
Note that to undertake the following programming the master user must be logged in
#
New Code #
New Code
0
3
3
3
0
1
2
#
#
#

®
MANUAL ACKP50EM-I
To delete a PIN user
To change the PIN of a PIN user
(This step must be done out
of programming mode)
To add a card user (Method 1)
This is the fastest way to enter cards,
user ID number auto generation.
Users can be deleted continuously without exiting
programming mode
To add a Pin user
ID number # Old PIN # New PIN # New PIN #
#
Read card
#
Read card
1
#
Read card
2
#
User ID
2
#
Card number
1
ID number. # Card number. #
1
#
ID number
1
To add a user in either card or PIN mode, i.e. in the mode. (Default setting)
32#
#
User ID number #
PIN
1
#
User ID no 1 #
PIN #
User ID no 2 #
PIN
1
The ID number is any number between 1 & 2000. The PIN is
any four digits between 0000 & 9999 with the exception of
1234 which is reserved. Users can be added continuously
without exiting programming mode as follows:
#
User ID number
2
Cards can be added continuously without exiting
programming mode
User can be added continuously without exiting
programming mode
User can be added continuously without exiting
programming mode
User can be added continuously without exiting
programming mode
To add a card user (Method 2)
This is the alternative way to enter
cards using User ID Allocation. In this
method a User ID is allocated to a
card. Only one user ID can be
allocated to a single card.
To add a card user (Method 3)
Card number is the last 8 digits
printed on the back of the card,user
ID number auto generation
To delete a card user by card. Note
users can be deleted continuously
without exiting programming mode
To delete a card user by user ID. This
option can be used when a user has
lost their card
To add a card user (Method 4)
In this method a User ID is allocated
to a card number. Only one user ID
can be allocated to the card number

®
MANUAL ACKP50EM-I
#
User ID
PIN #
Read card
Read card
2
#
0000
#
PIN
2
#
Card number
2
To add a card and PIN user in card and PIN mode ( )
31#
To add a card user in card mode ( )
30#
To delete All users
To unlock the door
3
Note users can be deleted continuously without exiting
programming
Add the card as for a card user
Press to exit from the programming mode
Then allocate the card a PIN as follows:
To delete a card user by card number.
This option can be used when the
user want to make the change but the
card has lost
To Add a card and Pin user
(The PIN is any four digits between
0000 & 9999 with the exception of
1234 which is reserved.)
To change a PIN in card and PIN
mode (Method 1) Note that this is
done outside programming mode so
the user can undertake this
themselves
To change a PIN in card and PIN
mode (Method 2) Note that this is
done outside programming mode so
the user can undertake this
themselves
To delete a Card and PIN user just
delete the card
The operating is the same as adding and deleting a card
user in
To Add and Delete a card user
To delete ALL users. Note that this is
a dangerous option so use with care
For a PIN user
For a card User
For a card and PIN user
Enter the then press
then enter
Read card 1234# PIN # PIN #
Read card Old PIN # New PIN # New PIN #
ID number # Old PIN # New PIN # New PIN #
30#

11.2 Door Settings
To set door relay strike time
Door Open Detection
To disable door open detection.
(Factory default)
Normal status: No keypad lockout
or alarm (factory default)
Keypad Lockout
Alarm and inside buzzer operate
To reset the Door Forced
Open warning
To reset the Door Open Too
Long warning
To set the alarm output time
(0-3 minutes)
Factory default is 1 minute
To enable door open detection
4
0-99 is to set the door relay time 0-99 seconds
##
Master Code 0〜99
Alarm output time
To remove the alarm
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in
magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the
inside buzzer will beep automatically to remind people to close the door and continue for 1 minute
before switching off automatically.
Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic
contact of the lock, if the door is forced open, or if the door is opened after 20 seconds ,the inside
buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0-3
minutes with the default being 1 minute.
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in
a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and the inside
buzzer will operate for 10 minutes, depending on the option selected below.
6 0 #
61#
7 0 #
7 1 #
72#
5#
0 〜3
(Factory default setting)
Read valid card
Read valid card
Master Code #
Master Code #
or
or
Close the door or
®
MANUAL ACKP50EM-I

12.THE UNIT OPERATING
AS A WIEGAND OUTPUT READER
In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be
connected to any controller which supports a Wiegand 26 bit input.
®
MANUAL ACKP50EM-I
Table of contents
Popular Keypad manuals by other brands

DMP Electronics
DMP Electronics Security Command 670-A Installation

Johnson Controls
Johnson Controls tyco Visonic KP-241 PowerG installation instructions

DMP Electronics
DMP Electronics Security Command 670 Installation

TimeIPS
TimeIPS IPS125T installation guide

Gecko
Gecko in.k800 Tech book

Honeywell
Honeywell Silent Knight 6820EVS Installation and optimization guide