GFA ELEKTROMATEN VR/K2E User manual

ENGLISH
EN
Illuminated RF keypad
Range: Digicode
GfA ELEKTROMATEN UK Ltd
INSTALLATION MANUAL
VR/K2E
40019022 00001

GALEO
Illuminated RF Keypad
INSTALLATION MANUEL
77
112 27
GALEOR
1] GENERAL INFORMATION
Illuminated RF Keypad
INSTALLATION MANUAL
HIGH RESISTANCE
TO VANDALISM
3] MOUNTING KIT
2] NOTES & RECOMMENDATIONS void
Mounting recommendations
Mount the keypad on a fat surface to a
Security advice
For securit
any vandalism and to insure the best mounting. y advice reasons, changethe factory default master code.
When selecting a master code and user code avoid
Thank you for buying our products and for the confdence you placed
sequencial codes (example : 3 4 5 6 7).
in our company.
IP64
-25°C a +70°C
Certifcation CE
Environmental test:
Salt spray
WEEE
Environmental tests:
vibrations
Certifcation FCC CFR 47
part 15 compliance
Wireless RF keypad.
Polished heavy duty Zamak®cast alloy.
Backlit keys.
Frequency : 433,92 Mhz.
2 channels (buttons «A» and «B»).
®
Compatible with Erone receivers.
Compact.
Surface mount.
®
Mounting with Torx screws
Partially sealed with epoxy.
22 User codes - 4 or 5 digits.
1 Master code - 5 digits.
Audible and visual feedback.
Modulation: AM/ASK.
®
Encoding: Keeloq hopping code
Dimensions (L x W x D):
GALEOR = 110 x 75 x 15mm,
Supply: Lithium battery 3,6V - LS14500.
Current consumption:
- 28 mA in transmission,
- 0,8uA in sleep-mode.
(M4x10)
®
Torx
screw)
®
T20 Torx
Spanner
Cache vis
plastique
(M4x30)
mounting
screws
Plastic
anchors Battery Foam
GALEOR 1 1 1 2 2 1 1
* Supplied.
EN
2
FCC ID : PWN1002000029
“The device complies with part 15 of the FCC Rules.
Operation is subjected to the following 2 conditions:
(1) this device may not cause harmful interference and
(2) this device must accept any interference received,
including interference that may cause undesired operation”

GALEO
Illuminated RF Keypad
INSTALLATION MANUEL
GALEOR
Illuminated RF Keypad
INSTALLATION MANUAL
EN
3
4] MOUNTING
5] USER CODES TABLE
Channel
User A B Code Name
01
02
03
04
05
06
07
08
09
10
11
Channel
User A B Code Name
12
13
14
15
16
17
18
19
20
21
22
Drill the 2 mounting holes (drill bit Ø 5 mm
and 35 MM hole depth) and the hole wiring access.
Insert the 2 plastic anchors in the holes.
Stick the foam to sealed The GALEOR on the back side
of the base (Important).
Place the back plate of the GALEOR and screw
on the wall using the supplied (M4x30)
mounting screws.
Remove the plastic protection of the battery
and then mount the keypad on the back
plate, placing frst the top in the hooks
and then the bottom.
Fasten the GALEOR keypad to the back plate
®
by using the supplied (M4x10) Torx screw
®
and T20 Torx spanner hardware.
Place the screw cap at the bottom
of the keypad.

GALEOR
Illuminated RF Keypad
INSTALLATION MANUAL
6] PROGRAMMING
GALEOR FACTORY SETTINGS :
- No user codes.
- Buzzer ON
- Time-out backlit : 3 Sec.
- Transmission time-out :
25 seconds
- Factory master code : 1 2 3 4 5.
- Programming time-out
: 10 seconds.
- Channel choices :
Channel 1 = A,
Channel 2 = B.
AUDIBLE FEEDBACKS :
1 beep : Power-up ( battery insertion )
1 long beep :
- Enter on menu,
- Validation of a programming choice,
- Exit from a menu choice.
2 beeps : Confrm enter in factory recovery
3 beeps : confrm factory recovery “A+1”
4 beeps :
- Confrm factory recovery “B+3”,
- Error for wrong channel,
- Error for insertion of a code already
Memorized.
USING RULES AND USER CODES:
- All the buttons can be used to
compose the personal access code,
except A and B.
- The master code must be composed
by 5 digits.
- The user codes can be composed by
4 or 5 digits according to initial setting
- The master code cannot be used as
transmission code.
EN
4
1 beep
Error message if the
Master code typed
corresponds to User
code in memory
1 beep = OK
(4 beeps = Error)
Type the 5 digits of
the new Master code
A0
Change
Master code
1 beep
Error message if the User
code typed corresponds to
a user code in memory
-------- or --------
the memory is full
-------- or --------
is 12345
1 beep = OK
(4 beeps = Error)
Then press :
-“A” = Only channel 1
-”B” = Only channel 2
-”A & B” = Channel 1
or Channel 2
A1
User code
programming
Type the digits
of the USER CODE
Press “0” to confrm
The keypad comes without any setting for the user digit
number. At the battery insertion the 12 leds start to
blink, waiting for this setting.
PRESS the key 4 for 4 sec. to set 4-digits
user codes
--> 4 beeps
PRESS the key 5 for 5 sec. to set 5-digits
user codes
--> 5 beeps
After this setting, the keypad will accept only user codes
composed by 4 or 5 digits, according to the choice made.
If no change is done ( change of the master code, user
code memorization, etc ) just by removing the battery
the keypad comes back the factory settings and requires
again to set the number of digits.
Once set the number of digits and made any
change, the data-base remains defnite and cannot
be changed unless a factory default procedure is
carried out ( see procedure “B+3”).
7] GETTING STARTED

REMINDER:
if the keypad blinks during 1 sec.
at the frst touch, check the battery.
GALEOR
Illuminated RF Keypad
INSTALLATION MANUAL
Buttons backlit switch off
except button 5
* The programming mode is limited to 10 sec. without any action on the keypad ( no buttons pressed )
Type 2 times the
MASTER CODE
EN
5
Programming exit*
1 beep
1 beep = OK
Press A and B
simultaneously
A4
Delete all user
codes
1 beep
Error message if the
code typed is not in
memory
1 beep = OK
(4 beeps = Error)
Type the digits
of the USER CODE
A5
Delete a single
user code
If the buzzer is
enabled it will
be disabled and
viceversa.
1 beep
A6
Buzzer ON / OFF
B
1 beep
button 5
blinks
A2
Memorization of
the channel onto
the receiver
Select the
corresponding relay
on the receiver
(within next 30 sec.)
Press A or B
1 beep
A7
Change User code
channel
Type the digits
of the USER CODE
Press the channel to
change ( A or B )
If the channel was
memorized it will be deleted,
if not it will me memorized.
CH DELETED : 2 Beeps
CH MEMORIZED : 1 Beep

GALEOR
Illuminated RF Keypad
INSTALLATION MANUAL
EN
6
FACTORY RECOVER
2 beeps
B+3
SIMULTANEOUSLY
FOR 30 SECONDS
Recover to
factory settings
2 beeps
3 beeps = OK 4 beeps = OK
Within 20 sec.
type the digits of a
memorized code
Within 20 sec.
type the digits of a
memorized code
A+1
SIMULTANEOUSLY
FOR 30 SECONDS
Master code reset
to factory value
12345
Doesn’t affect
the user codes
memorized
Deletes all User codes memorized
on the keypad, recovers the
choice to 4 or 5 digits, deletes
the link with the receiver and
resets the Master code to 12345.
Normal mode
8] FACTORY RECOVERY
To avoid any damage action ( intentional or not ) the factory recovery can be carried out only by the owner
of the 5-digit Master code or knowing any User code memorized ( with 4 or 5 digits) .
According to that and the fnal purpose of the recovery, follow the procedure “A+1” or “B+3”.
NOTE : At the end of procedure “B+3”, even the user code typed within the procedure will be deleted and
the keypad must be memorized again onto the corresponding receiver.

GALEOR
Illuminated RF Keypad
INSTALLATION MANUAL
EN
7
NOTES

GALEOR
Illuminated RF Keypad
INSTALLATION MANUAL
EN
8
Supplied by:
GfAELEKTROMATEN UK Ltd
Agincourt Road
Warwick CV34 6XZ
United Kingdom
Telephone: 01926 452452
Fax: 01926 336417
E-mail: sales@ gfa-elektromaten.co.uk
Web Site: www.gfa-elektromaten.co.uk
Warranty period : 12 months from the production date placed inside. In this
period if the appliance has any malfunction due to defective component, it will be
repaired or replaced by the manufacturer. The warranty doesn't cover the plastic
box. The assistance will be performed at the manufacturer site.
6] GUARANTEE
This manual suits for next models
1
Table of contents
Popular Keypad manuals by other brands

Burg Wächter
Burg Wächter secuENTRY 7711 operating instructions

Sewosy
Sewosy KR1000-M user manual

Elk Products
Elk Products Cross Platform Control ELK-M1KP user guide

urmet domus
urmet domus alha 1168/49 installation manual

Vantage Hearth
Vantage Hearth Equinox 41 EQ41TB-TI installation manual

Digiplex
Digiplex DGP-641 user manual