Giant Alarm System JJ-PKM-C01 User manual

1
GIANT
GIANT
GIANT
GIANT ALARM
ALARM
ALARM
ALARM SYSTEM
SYSTEM
SYSTEM
SYSTEM CO.,LTD
CO.,LTD
CO.,LTD
CO.,LTD.
.
.
.
SWING
SWING
SWING
SWING GATE
GATE
GATE
GATE OPENER
OPENER
OPENER
OPENER
JJ-PKM-C01
JJ-PKM-C01
JJ-PKM-C01
JJ-PKM-C01 USER
USER
USER
USER MANUAL
MANUAL
MANUAL
MANUAL
TEL
TEL
TEL
TEL NO.:86-595-22499516
NO.:86-595-22499516
NO.:86-595-22499516
NO.:86-595-22499516
FAX
FAX
FAX
FAX NO.:86-595-22492516
NO.:86-595-22492516
NO.:86-595-22492516
NO.:86-595-22492516
WEBSITE
WEBSITE
WEBSITE
WEBSITE:www.giantautogate.com
www.giantautogate.com
www.giantautogate.com
www.giantautogate.com

2
CAUTION:
CAUTION:
CAUTION:
CAUTION: This
This
This
This product
product
product
product must
must
must
must be
be
be
be installed
installed
installed
installed by
by
by
by well-trained
well-trained
well-trained
well-trained skilled
skilled
skilled
skilled
professionals
professionals
professionals
professionals in
in
in
in compliance
compliance
compliance
compliance with
with
with
with the
the
the
the regulations
regulations
regulations
regulations concerning
concerning
concerning
concerning the
the
the
the field
field
field
field
swing
swing
swing
swing gates
gates
gates
gates opener
opener
opener
opener device.
device.
device.
device. Unqualified
Unqualified
Unqualified
Unqualified personnels
personnels
personnels
personnels or
or
or
or those
those
those
those who
who
who
who do
do
do
do
not
not
not
not know
know
know
know the
the
the
the standards
standards
standards
standards applicable
applicable
applicable
applicable in
in
in
in this
this
this
this field
field
field
field should
should
should
should not
not
not
not carry
carry
carry
carry out
out
out
out
the
the
the
the installation
installation
installation
installation under
under
under
under any
any
any
any circumstances.
circumstances.
circumstances.
circumstances.
Every
Every
Every
Every time
time
time
time must
must
must
must cut
cut
cut
cut off
off
off
off power
power
power
power supply
supply
supply
supply before
before
before
before starting
starting
starting
starting installation,
installation,
installation,
installation,
operation
operation
operation
operation or
or
or
or maintenance.
maintenance.
maintenance.
maintenance.
Please
Please
Please
Please read
read
read
read the
the
the
the manual
manual
manual
manual carefully
carefully
carefully
carefully before
before
before
before installation.
installation.
installation.
installation. Incorrect
Incorrect
Incorrect
Incorrect
installtion
installtion
installtion
installtion or
or
or
or misuse
misuse
misuse
misuse of
of
of
of product
product
product
product may
may
may
may cause
cause
cause
cause seriously
seriously
seriously
seriously hurt
hurt
hurt
hurt on
on
on
on people
people
people
people or
or
or
or
damage
damage
damage
damage on
on
on
on other
other
other
other objectives.
objectives.
objectives.
objectives.
If
If
If
If the
the
the
the supplied
supplied
supplied
supplied wires
wires
wires
wires damaged
damaged
damaged
damaged or
or
or
or broken,
broken,
broken,
broken, it
it
it
it must
must
must
must be
be
be
be replaced
replaced
replaced
replaced by
by
by
by
the
the
the
the manufacturer,
manufacturer,
manufacturer,
manufacturer, its
its
its
its service
service
service
service agent
agent
agent
agent or
or
or
or qualified
qualified
qualified
qualified persons
persons
persons
persons in
in
in
in order
order
order
order to
to
to
to
avoid
avoid
avoid
avoid any
any
any
any hazard.
hazard.
hazard.
hazard.
Keep
Keep
Keep
Keep the
the
the
the wireless
wireless
wireless
wireless control
control
control
control system
system
system
system (push-button,
(push-button,
(push-button,
(push-button, transmitters
transmitters
transmitters
transmitters etc)
etc)
etc)
etc)
out
out
out
out of
of
of
of the
the
the
the reach
reach
reach
reach of
of
of
of children.
children.
children.
children.
Not
Not
Not
Not allow
allow
allow
allow children
children
children
children or
or
or
or other
other
other
other persons
persons
persons
persons to
to
to
to stand
stand
stand
stand near
near
near
near the
the
the
the motor
motor
motor
motor
while
while
while
while in
in
in
in operation.
operation.
operation.
operation.
Not
Not
Not
Not allow
allow
allow
allow to
to
to
to use
use
use
use transmitters
transmitters
transmitters
transmitters to
to
to
to control
control
control
control the
the
the
the gate
gate
gate
gate when
when
when
when it
it
it
it is
is
is
is out
out
out
out
of
of
of
of sight.
sight.
sight.
sight.
Not
Not
Not
Not allow
allow
allow
allow to
to
to
to install
install
install
install the
the
the
the products
products
products
products at
at
at
at the
the
the
the place
place
place
place where
where
where
where is
is
is
is corrosive,
corrosive,
corrosive,
corrosive,
inflammable,and
inflammable,and
inflammable,and
inflammable,and explosive.
explosive.
explosive.
explosive.
The
The
The
The manually
manually
manually
manually released
released
released
released part
part
part
part of
of
of
of front
front
front
front motor
motor
motor
motor can
can
can
can not
not
not
not be
be
be
be installed
installed
installed
installed
to
to
to
to the
the
the
the place
place
place
place where
where
where
where passerby
passerby
passerby
passerby could
could
could
could touch
touch
touch
touch when
when
when
when gate
gate
gate
gate closed.
closed.
closed.
closed.
Please
Please
Please
Please keep
keep
keep
keep this
this
this
this instruction
instruction
instruction
instruction for
for
for
for further
further
further
further reference.
reference.
reference.
reference.

3
1
1
1
1.P
P
P
PRODUCT
RODUCT
RODUCT
RODUCT DESPRICTION
DESPRICTION
DESPRICTION
DESPRICTION
2.SWING
2.SWING
2.SWING
2.SWING GATE
GATE
GATE
GATE OPENER
OPENER
OPENER
OPENER TECHNICAL
TECHNICAL
TECHNICAL
TECHNICAL PARAMETERS
PARAMETERS
PARAMETERS
PARAMETERS
Input Vo lt a g e : 24VDC 40W
Rotational Speed:250RPM
Rod's Running Speed:1.6cm/s
Rod's Max Travel:300mm
Continue running time: 5min
Max Single-leaf Length:2.5m*2
Travel Max Single-leaf Weight:200KG
Environment Temperature:-20°C~+50°C
Protection Calss:IP55

4
3.SPEC
3.SPEC
3.SPEC
3.SPEC SIZE
SIZE
SIZE
SIZE
Fig.3

5
5.INSTALLATION
5.INSTALLATION
5.INSTALLATION
5.INSTALLATION DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
5.1 Required tools for installation
Fig.4
5.2 Installation diagram
Fig.5
Fig.6

6
5.3 Installation size
Fig.7
5.4 Description of installation
Fig.8
Different connecting method for front and rear bracket.

7
Using different installation method according to different
material and environment for front bracket.
Connection for rear bracket and motor
The height difference for installing the front and rear bracket.
Installation for front bracket

8
Open the gate manually:Release by spanner then lift it.

9
Swing
Swing
Swing
Swing gate
gate
gate
gate opener
opener
opener
opener cnotrol
cnotrol
cnotrol
cnotrol panel
panel
panel
panel
Manual
Manual
Manual
Manual for
for
for
for Control
Control
Control
Control Panel
Panel
Panel
Panel
1.
1.
1.
1. Technical
Technical
Technical
Technical Parameters:
Parameters:
Parameters:
Parameters:
1. Control Panel Voltage Input: 220VAC
2. Motor
’
s Voltage: 12VDC/24VDC
3. Encoder For transmitter: Our own customed rolling code.
4. Support remote control:Can memorize 20PCS transmitters at most
5. Range of application: Suit for all double arms swing gate opener

10
2
2
2
2.Wiring
Wiring
Wiring
Wiring diagram
diagram
diagram
diagram for
for
for
for control
control
control
control panel:
panel:
panel:
panel:
3.
3.
3.
3. Functions
Functions
Functions
Functions and
and
and
and testing:
testing:
testing:
testing:
1. Indicator LED light: It
’
salways on once the system electrified. LED indicator
for “auto-closing”flashes every 1second. It turns off when enter into the learning code
state or removing code state; it flashes twice after successfully learning code or
removing code.
2. Transmitter : using our company own customed rolling code. Singe-leaf button
controls opening and closing of MOTOR2, double-leaf button simultaneously controls
opening and closing of MOTOR1 & MOTOR2. The control panel can memorize 20
transmitters at most.
3. Code-learning: press and hold learning button for 1second then release, LED
turns off and press any button of transmitter, then LED flashes twice, now the codes
has been learnt to the panel. If there is no any signals received within 5seconds, the

11
LED will light and then exit code-learning state .
4. Code-removing: press and hold learning button (once you press learning
button,LED is off), 5seconds later LED lights up, now the codes has been removed.
5, Instructions for all terminals:
2SIDE
This terminal is same as “double-leaves button”of transmitter.
It controls the dual doors as Open-Stop-Close-Stop-Open
cyclically
1SIDE
This terminal is same as “Single-leaf button”of transmitter.
It controls the single door as Open-Stop-Close-Stop-Open
cyclically
COM Common terminal for connecting ground
MOTO 1
Wiring of motor1: should connect wires of the motor which opens
first.Or connecting the wires of motor installed at the side of door
with thrust plate.
MOTO2(DELAY)
Wiring of motor2: should connect wires of the motor which you
could use single-leaf button to control.
24V/12V-12V/0V-0V/12V
Supply AC 12V*2 (switch high-speed running to low-speed
running)Supply DC 12V (Motor only runs in low-speed, Need to
adjust HSPEED TIME trimmer to the minimum position)
Supply DC 24V &12V together (switch high-speed running to
low-speed running)
UPS+/-
External 12V storage battery, the storage battery can be charged.
When there is no power supply,the UPS will start working
automatically. The standby current of UPS when it is working is
20mA,the current is around 1.5A when the motor is
running.(specific current depends on the actual usage)
LOCK12+/- Ternimal for Electric lock.
SWIPE CARD
Swipe card to open two gates, active low, auto-closing is enabled
after the door opened.

12
INFRARED
Terminal for photocells, active low, when the obstacle sensed by
photocell while the door is closing, the door will stop and then
rebound to open.
COM Common terminal for connecting ground
VCC
12-28V output voltage; supply the power for photocells or other
saftey devices; current ≤200mA.
6. Motor running speed: Soft start when open and close the door, 700ms later
then switch to high-speed running. (Time adjusting: 0~33 seconds high speed time
can be adjusted by HSPEED TIME trimmer). When high-speed running time ends, it
switches into low-speed running till the motor stops running. When the motor stops in
the halfway for the first time during it runs from open limit position or close limit
position, then high-speed running time will adjust automatically based on previous
running time.
7. High-speed running time adjustment: Adjusting 0~30s high speed running
time through HSPEED TIME trimmer. When the trimmer turns to the minimum, it’s
0s, the high-speed running disabled, the motor keeps running in low-speed. Only
when both motors working, then high-speed running timing enabled.
8. Limit & obstacle sensitivity adjustment: During the opening and closing, the
motor stops running once the limit & obstacle sensitivity signals sensed. Sensitivity of
the two motors are set seperately. Adjusting the sensitivity of motor1 through
MOTOR1 trimmer, while MOTOR2 trimmer control sensitivity of motor2. Notice:
Arm-type motors only have the funcion of obstacle sensitivity, no functions of limit.
9. MOTOR1&2 opening/closing delay time adjustment: When opening the door,
motor2 opens first then motor1 opens later; while closing the door, motor1 closes first
then motor2 closes. And opening/closing delay time can be adjusted 0~30s.
10. Auto closing time adjustment: Auto closing funtion enabled when opening
the door by swiping the card which should have card-reader installed. Auto closing
time can be set for 0 second,5seconds and 10 seconds by using jumper. The auto

13
closing is disabled when you set 0 second. No jumper connected means 0 second.
When jumper 1 connect with jumper 2 it means 10 seconds. When jumper 2 connects
with jumper 3 it means 5 seconds. The LED indicator for auto closing time count
down flashes every 1second.
11. Motor delay time protection: As soon as the motor running continuously
more than 60s, the motor will automaticlly stop working to protect the motor.
12. Motor direction indentification:When one side of door installed thrust plate
or the contoller has function of setting order of opening & closing, or functions of
swiping card, make sure all the wiring connections of 2 motors are correct. When the
motor is running, if motor direction LED indicator is blue, now the motor should be in
“opening”operation, if no, please exchange the wiring connections of 2 motors; when
the motor direction LED indicator is RED, the motor should be in the
“closing”operation. If no, please exchage the wiring connections. Otherwise can not
open and close the door normally.
Table of contents