Page 2 of 8
Contents
Installation Procedure: Fixed
Installation Procedure: Opening
Pyramid Installation Instructions
Points to note prior to commencing installation:
1. The Pyramid should arrive on site in undamaged packaging, which includes sterling
board side protection, polyfoam glass protection and low-tack tape base protection.
Please inspect for damage to packaging and/or rooflight and advise Glazing Vision
upon receipt.
2. Enclosed within the box containing this manual is a roll of butyl tape, the required
number of fixing woodscrews and a number of horseshoe packers. The installation
kit supplied with electrical units contains a transformer, two switches and any
additional optional items selected at time of order.
3. For electrically operated Pyramids there are two standard cables emerging from the
motor housing, this includes two and six core cables both of which have red
identification labels (labels should not be removed until final installation) refer to
Glazing Vision standard drawing 404-ASS-426 for details of wiring requirements.
4. The switch used to control the operation of the Pyramid is a single pole double throw
(SPDT) centre sprung type. This switch will allow you to operate and stop at any
position between the fully open and closed positions. This switch also contains a tri-
colour LED to display rooflight status to the user. The correct control switch is
supplied in the installation kit and must be installed to avoid invalidating the
warranty. This switch can be installed in a maintenance area if required and another
Pyramid Installation Instruction Manual
VV-INST –v2.1 –30.01.15
GLAZING VISION Ltd, Saw Mills Road, Diss, Norfolk, IP22 4RG
Telephone: 0333 8000 881 Fax: 0333 8000 882
Registered in England and Wales Reg. No. 2987024