PRO-series Model E3 Electrodeless Conductivity Transmitter Rev. 0-201
10
TABLE OF CONTENTS (continued)
SECTION 3 TRANSMITTER CONFIGURATION
3.1 Selecting LANGUAGE to Operate Transmitter......................................34
3.2 Configuring Sensor Characteristics:
SELECT MEASURE (conductivity, concentration or TDS) .........34-35
Select DISPLAY FORMAT..........................................................35-36
Select Temperature COMPENSATION.......................................36-37
CONFIG CONC or CONFIG TDS Measurement
(not needed for conductivity) .................................................37-41
CONFIG LINEAR or CONFIG T-TABLE Temp. Comp. (con-
figuration not needed for other compensation methods) .......42-45
SET FILTER Time............................................................................45
ENTER NOTE (top line of MEASURE screen) ..............................45-46
Select TEMP ELEMENT Type ....................................................46-47
SET T FACTOR (sensor’s GLI-certified “T”factor) .....................47-48
3.3 SET °C OR °F (temperature display format) .........................................48
3.4 Configuring Analog Output:
SET PARAMETER (representation) ................................................49
SET 4 mA and 20 mA VALUES (range expand) .........................49-50
SET FILTER Time............................................................................50
SET FAIL LEVEL Mode (off, 4 mA or 20 mA) ..................................50
3.5 SET PASSCODE (feature enabled or disabled) ...................................51
3.6 Configuration Setting Summary (ranges/choices and defaults) .......52-53
SECTION 4 TRANSMITTER CALIBRATION
4.1 Important Information .......................................................................54-55
4.2 ZERO Procedure (first-time sensor calibration only)........................55-56
4.3 Conductivity Calibration:
COND CAL Method.....................................................................56-58
SAMPLE CAL Method.................................................................59-60
4.4 % Concentration Calibration:
CONC CAL Method.....................................................................60-62
COND CAL Method..........................................................................62
4.5 TDS Calibration................................................................................62-64
4.6 Analog Output Calibration................................................................64-65
SECTION 5 TEST/MAINTENANCE
5.1 STATUS Checking (transmitter and sensor) ....................................66-67
5.2 HOLD OUTPUT.....................................................................................67
5.3 OUTPUT Test Signal........................................................................67-68
5.4 Firmware (EPROM VERSION) Checking ..............................................68
5.5 SELECT SIM Measurement .............................................................68-69
5.6 SIM SENSOR Setting............................................................................69
5.7 RESET CONFIGURE Values to Factory Defaults............................69-70
5.8 RESET CALIBRATE Values to Factory Defaults ..................................70