manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GM Lighting
  6. •
  7. Lighting Equipment
  8. •
  9. GM Lighting V120-RGBW-DMX User manual

GM Lighting V120-RGBW-DMX User manual

Model: V120-RGBW-DMX
PRODUCT DIMENSION
Input
Voltage Max Load
Output
Voltage
AC 100-240V 660W@110V
1320W@220V
Max. 4x1.5A
DC 100-240V
Output
Current
PRODUCT DATA
Size(LxWxH)
180.5x73.6x38mm
• RDM enabled DMX high voltage LED strip controller
• Output for high voltage DC100~240V LED Strip
• Standard DMX512 compliant control interface
• RDM function enabled to realize intercommunication between DMX master and decoder.
• For example, DMX decoder’s address can be assigned by DMX master console
• With digital display to show data directly, easily to set and show DMX address.
• Total 4 channels LED output, common anode
• DMX address manually settable
• DMX channel quantity from 1CH~4CH settable
• Output PWM frequency from 500HZ ~ 35K HZ settable, but do not set it higher than 3KHz.
• Output dimming curve gamma value from 0.1 ~ 9.9 settable
• Waterproof grade:IP67
Ambient
Temp.
-20ºC ~ +50ºC
170.0
180.5
73.6
38.0
D+
D-
GND
DMX512 signal input
Common Anode Output(+)
CH 3: B / output(-)
CH 1: R / output(-)
CH 2: G / output(-)
AC100-240V
power input
D+
D-
GND
DMX512 signal input
AC DMX512& RDM Co nt r o l l er
IP67
PRI:
Uin=100-240VAC
Iin=6 A Max
Black
Grey Wh ite
Green
GND
D+
D-
DMX INP UT&OUTPU T
Black
Red
Green
Yellow
White
V+
1-
2-
3-
4-
R-
G-
B-
W-
WW-
CW-
WW-
CW-
LED OUT PUT
ta:-2 0℃-+50℃
SEC:
Uout=4x(100-240)VDC
Iout=4x1.5A
Pout=4x(150-360)W
DMX
INPUT
DMX
OUTPUT
AC
INPUT
DC
OUTPUT
CH 4: W / output(-)
211021 INSTALLATION GUIDE | RGBW DMX DECODER | 1 OF 4
INSTALLATION GUIDE
RGBW DMX DECODER
3) LED Strip2) Waterproof
Connector
1) LED Controller
WATERPROOF CONNECTOR ASSEMBLY
3
6 mm
20 mm
1) Prepare stripped wires as below
2)
Disassemble the connector, feed cable in each component
in below order, screw each wire on appropriate terminal,
and ensure same LED strip color wiring with corresponding polarity.
3) Screw all components ghtly.
INSTALLATION
1
TURNING OFF POWER
WARNING: Electric Shock Hazard. May result in serious injury or death.
Turn power OFF at circuit breaker prior to installaon.
ON
OFF
ON
OFF
ON
OFF
2
INSTALL COMPONENTS
4
TURN POWER ON AT CIRCUIT BREAKER
Install Addional Components, Verify Connecons and turn main power ON at breaker.
Turn power OFF at circuit breaker and verify all connecons.
Review WIRING and TROUBLESHOOTING
SYSTEM WORKING IMPROPERLY?
ON
OFF
ON
OFF
ON
OFF
211021 INSTALLATION GUIDE | RGBW DMX DECODER | 2 OF 4
To set desired DMX512 address through buttons,
button A is to set “hundreds” position,
button B is to set “tens” position,
button C is to set “unit” position.
Choose DMX Channel (Factory default DMX channel is 4CH)
Press and hold down both buttons B+C simultaneously for over 3 seconds, CH digital display flashes, then
keep short pressing button A to choose 1/2/3/4, which means total 1/2/3/4 channels. Press and hold down
button A for >3 seconds to confirm the setting. Factory default is 4 DMX channels.
For example the DMX address is already set as 001.
1CH=1 DMX address for all the output channels, which all will be address 001.
2CH=2 DMX addresses , output 1&3 will be address 001, output 2&4 will be address 002
3CH=3 DMX addresses, output 1, 2 will be address 001, 002 respectively, output 3&4 will be address 003
4CH=4 DMX addresses, output 1, 2, 3, 4 will be address 001, 002, 003, 004 respectively
Choose PWM frequency (Factory default PWM frequency is PF1 1KHz)
Press and hold down both buttons A+B simultaneously for over 3 seconds, digital display will show PF1, PF
means output PWM frequency, the digit 1 will flash, which means frequency, then keep short pressing button C
to select a frequency from 0-9 and A-J, which stand for following frequencies:
0=500Hz, 1=1KHz, 2=2KHz, ..., 9=9KHz, A=10KHz, B=12KHz, C=14KHz, D=16KHz, E=18KHz, F=20KHz,
H=25KHz, J=35KHz.
Then press and hold down button C for >3 seconds to confirm the setting.
Note: DO NOT set the PWM frequency higher than 3KHz to avoid over heat and damage to the device.
Operaon
Set DMX address (Factory default DMX address is 001)
Press and hold down any of the 3 buttons for over 3 seconds, digital display flashes to enter into address
setting, then keep short pressing button A to set “hundreds” position, button B to set “tens” position, button C to
set “units” position, then press and hold down any button for >3 seconds to confirm the setting.
Choose Dimming Curve Gamma Value (Factory default dimming curve value is g1.0)
Press and hold down all buttons A+B+C simultaneously for over 3 seconds, digital display flashes g1.0, 1.0
means the dimming curve gamma value, the value is selectable from 0.1-9.9, then keep short pressing button B
and button C to select corresponding digits, then press and hold down both buttons B+C for >3 seconds to
confirm the setting.
<1
1.0
1.5
2.5
3.5 6.5
0.90.9
0.8
gamma
value
output
brightness
level
>1
DMX value level
DMX signal indicator : When DMX signal input is detected, the indicator on the display following after the digit
of “hundreds” position of DMX address turns on red .
A B C
211021 INSTALLATION GUIDE | RGBW DMX DECODER | 3 OF 4
AC DMX5 12& R
Zone 1
Junction Box
Zone 2
Zone 3
GM RGBW High Volt Tape
GM RGBW High Volt Tape
GM RGBW High Volt Tape
DM Con tr ol le r
IP67
PRI:
Uin=100-240VAC
Iin= 6A Max
Blac k
Grey W hite
Gree n
GND
D+
D-
DMX INPUT&OUTPUT
Blac k
Red
Gree n
Yello w
White
V+
1-
2-
3-
4-
R-
G-
B-
W-
WW-
CW-
WW-
CW-
LED OU TPUT
ta:- 20℃-+50℃
SEC:
Uout=4x(100-240)VDC
Iout=4x1.5A
Pout=4x(150-360)W
DMX
INP UT
DMX
OUTPUT
AC
INP UT
DC
OUT PUT
AC DMX5 12& RDM Co nt ro ll er
IP67
PRI:
Uin=100-240VAC
Iin= 6A Max
Blac k
Grey W hite
Gree n
GND
D+
D-
DMX INPUT&OUTPUT
Blac k
Red
Gree n
Yello w
White
V+
1-
2-
3-
4-
R-
G-
B-
W-
WW-
CW-
WW-
CW-
LED OU TPUT
ta:- 20℃-+50℃
SEC:
Uout=4x(100-240)VDC
Iout=4x1.5A
Pout=4x(150-360)W
DMX
INP UT
DMX
OUT PUT
AC
INP UT
DC
OUTPUT
AC DMX5 12& RDM Co nt ro ll er
IP67
PRI:
Uin=100-240VAC
Iin= 6A Max
Black
Grey W hite
Gree n
GND
D+
D-
DMX IN PUT&O UTPUT
Blac k
Red
Green
Yello w
Whit e
V+
1-
2-
3-
4-
R-
G-
B-
W-
WW-
CW-
WW-
CW-
LED OU TPUT
ta:- 20℃-+50℃
SEC:
Uout=4x(100-240)VDC
Iout =4x1. 5A
Pout=4x(150-360)W
DMX
INP UT
DMX
OUT PUT
AC
INP UT
DC
OUT PUT
Restore to Factory Default Seng
Press and hold down both buttons A+C for over 3 seconds until the digital display turns off and then turns on
again, all settings will be restored to factory default.
Default settings are as follows:
DMX Address: 001
DMX Address Quantity: 4CH
PWM Frequency: PF1
Gamma: g1.0
The supported RDM PIDs are as follows:
Wiring diagram
DISC_UNIQUE_BRANCH
DISC_MUTE
DISC_UN_MUTE
DEVICE_INFO
DMX_START_ADDRESS
IDENTIFY_DEVICE
SOFTWARE_VERSION_LABEL
DMX_PERSONALITY
DMX_PERSONALITY_DESCRIPTION
SLOT_INFO
SLOT_DESCRIPTION
MANUFACTURER_LABEL
SUPPORTED_PARAMETERS
AC120~277V
V- D+D -V+ GND
DC IN PUT DM X OUTPU T
DMX512 Wa ll P anel
Co nt r ol l er
G- G-
B- B-
W- W-
R - R -
G- G-
B- B-
W- W-
R - R -
G- G-
B- B-
W- W-
R - R -
Warning: High output voltage!
IMPORTANT!
RGBW DMX Master Controller
Transformer
RGBW DMX Decoder
©2021 GM Lighting
Specifications are subject to change
without notice.
18700 Ridgeland Ave.,
Tinley Park, IL 60477
Toll-Free: (866) 671-0811
FAX: (708) 478-2640
www.gmlighting.net
[email protected]
211021 INSTALLATION GUIDE | RGBW DMX DECODER | 4 OF 4

Other GM Lighting Lighting Equipment manuals

GM Lighting LT-3600RF User manual

GM Lighting

GM Lighting LT-3600RF User manual

GM Lighting LEDTask LTR-E Series User manual

GM Lighting

GM Lighting LEDTask LTR-E Series User manual

GM Lighting LEDTask LTR-S Series User manual

GM Lighting

GM Lighting LEDTask LTR-S Series User manual

GM Lighting LTR Series User manual

GM Lighting

GM Lighting LTR Series User manual

GM Lighting LEDTask LTR-P-WP User manual

GM Lighting

GM Lighting LEDTask LTR-P-WP User manual

GM Lighting LEDTASK User manual

GM Lighting

GM Lighting LEDTASK User manual

Popular Lighting Equipment manuals by other brands

SMUKEE OW-3812 user manual

SMUKEE

SMUKEE OW-3812 user manual

Whelen Engineering Company M2 Series quick start guide

Whelen Engineering Company

Whelen Engineering Company M2 Series quick start guide

Beaba Veilleuse Lutin Instructions for use

Beaba

Beaba Veilleuse Lutin Instructions for use

Chauvet Professional onAir IP panel min user manual

Chauvet Professional

Chauvet Professional onAir IP panel min user manual

Party Light & Sound PARTY-PAR-STROBE user manual

Party Light & Sound

Party Light & Sound PARTY-PAR-STROBE user manual

Robe SPOT 250 XT user manual

Robe

Robe SPOT 250 XT user manual

Bestway FlowClear owner's manual

Bestway

Bestway FlowClear owner's manual

SWITCH MADE CANNON user manual

SWITCH MADE

SWITCH MADE CANNON user manual

Lycian 1290 XLT Setup & operation

Lycian

Lycian 1290 XLT Setup & operation

COLBOR PL8-R quick start guide

COLBOR

COLBOR PL8-R quick start guide

FLUVO Mushroom Operator's manual

FLUVO

FLUVO Mushroom Operator's manual

Polarlite 1547244 operating instructions

Polarlite

Polarlite 1547244 operating instructions

Rollei Lumen Solo manual

Rollei

Rollei Lumen Solo manual

Contest VERSATILE COLOR VPAR-70RGBL user guide

Contest

Contest VERSATILE COLOR VPAR-70RGBL user guide

WAC Lighting GATE 12V installation instructions

WAC Lighting

WAC Lighting GATE 12V installation instructions

ITEM LED Light Fitting E 20W user guide

ITEM

ITEM LED Light Fitting E 20W user guide

ALS HBA-60NW2 quick start guide

ALS

ALS HBA-60NW2 quick start guide

ProLights Jet PAR7ZIP user manual

ProLights

ProLights Jet PAR7ZIP user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.