golmar G2+ User manual

Code 50123134 TDQ-IPCAM G2+ EN REV.0221
DQ-IPCAM G2+
IP CAMERAS UNIT
ON
1
2
3 4
RJ45
Adapter
DC 12V 1A
DIP SWITCH
Micro SD
Card slot
LED1
LED2
RESET
Mode
12458990 V01
Switch
CAMERA UNIT DQ-IPCAM-G2+
GOLMAR S.A.
C/ Silici, 13
08940-SPAIN
MADE IN CHINA
USB HDMI
BUS
BUS
TECHNOLOGY
INSTRUCTIONS MANUAL

INTRODUCTION
First and foremost we would like to thank you for purchasing this product.
Our commitment to achieving the satisfaction of customers like you is manifested through our ISO-9001 certification
and the manufacture of products like the one you have just purchased.
Its advanced technology and strict quality control will ensure that customers and users enjoy the numerous features
that this device offers. To get the most out of them and ensure proper operation from day one, we recommend that you
read this instruction manual.
CONTENTS
2
SET-UP WARNINGS
- DQ-IPCAM G2+ IP cameras unit connector.Do not overtighten the screws on the
- l, DQ-IPCAM G2+, Before connecting the device, check the connections between the power supply unit, door pane
switches, RD-G2+ modules, distributors, monitors, telephones and hands-free audio terminals.
- Use the Golmar RAP-GTWIN/HF cable (2x1mm ) in installation of video door entry system.
- Use the Golmar UTP-5E305 (RJ-45) cable for connection of the DQ-IPCAM G2+ IP camera unit to the switch and
connection of the IP cameras.
- Always follow the instructions contained in this manual.
2
Introduction.....................................................................................................................................................................
Contents.........................................................................................................................................................................
Set-up warnings..............................................................................................................................................................
Safety precautions..........................................................................................................................................................
Characteristics................................................................................................................................................................
Installation modes.............................................................................................................................................................
DQ-IPCAM G2+ unit instaled in monitor bus.................................................................................................................
DQ-IPCAM G2+ unit instaled in door panel bus.............................................................................................................
DQ-IPCAM G2+ unit instaled in inner door panel bus & general door panel bus.............................................................
Description of the DQ-IPCAM G2+ IP cameras unit...........................................................................................................
Description..................................................................................................................................................................
Installation........................................................................................................................................................................
Illustration of DQ-IPCAM G2+ IP cameras unit installation............................................................................................
Setting IP addresses of the IP cameras...................................................................................................................
Setting of DQ-IPCAM G2+ IP cameras unit (local mode)........................................................................................
Setting of DQ-IPCAM G2+ IP cameras unit (web browser).....................................................................................
Setting the button code (up to 32 addresses/apartments)......................................................................................
Wiring diagrams............................................................................................................................................................
Installation of video door entry system with DQ-IPCAM G2+ unit installed in monitor bus............................................
Installation of video door entry system with DQ-IPCAM G2+ unit installed in door panel bus........................................
Installation of video door entry system with DQ-IPCAM G2+ unit installed in inner door panel & general door panel bus...
Installation of video door entry system with 1 access panel.........................................................................................
Installation of video door entry system with DQ-IPCAM G2+ unit and 2 access panel..................................................
Installation of video door entry system with DQ-IPCAM G2+ unit and 3 access panel..................................................
Connection of Golmar DC an AC lock releases. Golmar..............................................................................................
Special code & operation of the IP camera preview menu (only ART 7W/G2+ monitor with V.08 and later).................
Compliance...................................................................................................................................................................
2
2
2
3
3
4
5
6
7
7
8-10
11-14
15-21
22-25
26
27
28
29
30
31
32
33-35
36
DQ-IPCAM G2+ IP CAMERAS UNIT

3
SAFETY PRECAUTIONS
- Always disconnect the power supply before installing or making modifications to the device.
- The fitting and handling of this device must be carried out by authorised personnel.
- The wiring must run at list 40 cm. de cualquier otra instalación.
- Install the DQ-IPCAM G2+ unit in a dry protected location free from risk of dripping or splashing water.
- Avoid locations that are humid, dusty or near heat sources.
- Ensure that the air vents are free from obstruction so that air can circulate freely.
- G2+ To prevent damage, must be firmly secured in place.the DQ-IPCAM unit
CHARACTERISTICS
- DQ-IPCAM G2+ camera unit with installation to IP cameras (switch required) via UTP cable with RJ45 connector.
- Up to 1 DQ-IPCAM G2+ camera unit per trunk (building).
- Up to 16 CCTV IP cameras with ONVIF protocol per DQ-IPCAM G2+ camera unit.
- Up to 32 DQ-IPCAM G2+ camera units (maximum 1 camera unit per building, up to 32 buildings):
- ART 7W monitors with V08 and later can display the IP cameras in your building.
- Up to 1 DQ-IPCAM G2+ camera unit connected on the bus of the general door panel(s).
- ART 7W monitor(s) guard with V08 and later connected, can display only the IP cameras on the bus of the general
door panel(s), see page 6.
- 1 DQ-IPCAM G2+ camera unit counts as 1 door panel:
-1 DQ-IPCAM G2+ camera unit installed in a building will allow maximum 3 access door panels in the building.
-1 DQ-IPCAM G2+ camera unit installed on the general door panel(s) bus will allow maximum 3 general access
door panel(s).
- The DQ-IPCAM G2+ camera unit is connected to the door panel bus or monitor bus of the G2+ video door entry
system (see pages 4 to 6).
- Status LED (green): Standby (on) / unit reset process (fast flashing) and displaying an IP camera (slow flashing).
- Status LED (red): Standby (on) / configuring IP cameras (slow flashing).
- Reset button of the DQ-IPCAM G2+ camera unit.
- The ART 7W monitor with V08 and later is compatible with the DQ-IPCAM G2+ camera unit for viewing IP cameras
from the home monitor, by default this function is disabled (programmable by the installer).
- The display of the IP cameras has a maximum time of 90 sec. or until the ART 7W monitor icon is pressed.
- During the display of the IP camera(s), the channel of the corresponding building will be on busy channel.
- During the display of the guard monitor “ART 7W V.08 and later” (general door panel) of the IP camera(s), the
channel of the general door panel(s) will be on busy channel.
- DQ-IPCAM G2+ camera unit in installations with RD-G2+ modules (RD-G2+ must be V.03 or later).
- Guard monitor “ART 7W V.08 and later” in installations with RD-G2+ modules (RD-G2+ must be V.03 or later).
DQ-IPCAM G2+ IP CAMERAS UNIT

4
INSTALLATION MODES OF THE DQ-IPCAM G2 + CAMERA UNIT
- The DQ-IPCAM G2+ camera unit is installed in monitor bus.
Important: One DQ-IPCAM G2+ camera unit counts as 1 panel, maximum 3 access door panels in the building. (See
installation diagrams, pages 26, 30 and 31).
A
E
FA-G2+
G2+ installation building
Monitor BusDoor panel Bus
EL632 G2+ SE
D4L-G2+
D4L-G2+
D
END OF LINE
ON
OFF
END OF LINE
Apartment 29
Apartment 30
Apartment 3 Apartment 4
Apartment 31 Apartment 32
Apartment 1 Apartment 2
C
B
PL
M
DQ-IPCAM
Technical room
ART 7W ART 7W
Ports PoE
SWITCH
BUS
BUS
( )
1
FA-G2+
G2+ installation building
Monitor Bus
Door panel Bus
D4L-G2+
D4L-G2+
D
END OF LINE
ON
OFF
END OF LINE
ART 7W
Apartment 29
Apartment 30
Apartment 3 Apartment 4
Apartment 31 Apartment 32
Apartment 1 Apartment 2
C
PL
M
ART 7W
DPM-G2+
E
AA1
A2 A3
A4
( )
*
A1=A2=A3= 80m.
Note: DQ-IPCAM unit,
counts as 1 door panel.
Max. distance 1m.
( )
*
Access door panels
DQ-IPCAM
B
X
Technical room
( )
1
( )
1
Camera IP/PoE
SWITCH
Ports PoE
Camera IP/PoE
BUS
BUS
Up-Link
Ports
Up-Link
Ports
DQ-IPCAM G2+ IP CAMERAS UNIT
*
( )
(Distances with Golmar cable (twisted pair 2x1mm ).RAP-2150
2
IMPORTANT:
- For more information see characteristics, page 3.
- For description, installation, configuration and programming of door panels and monitors, see the corresponding manuals.
ABC
80m 80m 80m
Cable D
30m
B+ +CD
190m
RAP-GTWIN/HF 2x1mm
2
*
( )
Distances and cross-sections:

5
*
( )
(Distances with Golmar cable (twisted pair 2x1mm ).RAP-2150
2
IMPORTANT:
- For more information see characteristics, page 3.
- For description, installation, configuration and programming of door panels and monitors, see the corresponding manuals.
ABC
80m 80m 80m
Cable D
30m
B+ +CD
190m
RAP-GTWIN/HF 2x1mm
2
*
( )
Distances and cross-sections:
- The DQ-IPCAM G2+ camera unit is installed in door panel bus.
Important: One DQ-IPCAM G2+ camera unit counts as 1 door panel, maximum 3 access door panels in the building.
(See installation diagrams, pages 27, 30 and 31).
FA-G2+
G2+ installation building
Monitor Bus
D4L-G2+
D4L-G2+
D
END OF LINE
ON
OFF
END OF LINE
ART 7W
Apartment 29
Apartment 30
Apartment 3 Apartment 4
Apartment 31 Apartment 32
Apartment 1 Apartment 2
C
B
PL
M
ART 7W
DPM-G2+
E
A
A2 A3
A4
Technical room
( )
*
A1=A2=A3=A4= 80m.
Note:
Access door panels
Max. distance 1m.
( )
*
DQ-IPCAM
Ports PoE
SWITCH
A1
Door panel Bus
Camera IP/PoE
( )
1Note: DQ-IPCAM unit,
counts as 1 door panel.
( )
1
Up-Link
Ports
DQ-IPCAM G2+ IP CAMERAS UNIT
INSTALLATION MODES OF THE DQ-IPCAM G2 + CAMERA UNIT

6
Installation with 4 buildingd, 128 monitors, 4 RD-G2+ “block mode”, DQ-IPCAM G2+ installed on the door panel bus of each building and on the
general door panels bus, 12 inner door panels, 3 general door panels and 1 ART 7W monitor as guard monitor on the general bus.
F
FA-G2+
DPM-G2+
E
BUILDING 2
D4L-G2+
D4L-G2+
D
End of Line
ON
OFF
End of Line
ART 7W
Apartment 29
Apartment 30
Apartment 3 Apartment 4
Apartment 31 Apartment 32
BUILDING 1
Apartment 1 Apartment 2
D4L-G2+
D4L-G2+
D
End of Line
ON
OFF
End of Line
Apartment 61 Apartment 62
Apartment 35 Apartment 36
Apartment 63 Apartment 64
Apartment 33 Apartment 34
D4L-G2+
D4L-G2+
D
End of Line
ON
OFF
End of Line
Apartment 93 Apartment 94
Apartment 67 Apartment 68
Apartment 95 Apartment 96
Apartment 65 Apartment 66
D4L-G2+
D4L-G2+
D
End of Line
ON
OFF
End of Line
Apartment 125 Apartment 126
Apartment 99 Apartment 100
Apartment 127 Apartment 128
Apartment 97 Apartment 98
BUILDING 4BUILDING 3
Lock release
max. 12 Vdc/270mA
Max. distance 1m.
Distances and cross-sections:
ABC
80m
Cable D
30m
B+ +CD
190m
F
220m
RAP-GTWIN/HF 2x1mm
2
( )
*
80m 80m
( )
*
G
G1
G2 G3
G4
FA-G2+
RD-G2+(1)
FA-G2+
RD-G2+(2)
FA-G2+
RD-G2+(3)
FA-G2+
RD-G2+(4)
C C C
( )
*( )
*( )
*( )
*
B B B B
G
80m
G+F
300m
C
IN OUT
FA
PL
M
PL PL
IN OUT
FA
PL
M
IN OUT
FA
PL
M
IN OUT
FA
PL
M
PL
Building 1
Important:
Máx. distance of 300m from general door panel to first RD-G2+
configured as “amplifier mode”.
( )
1
( )
1
E
15m
Technical room
DPM-G2+
A
A1
A2 A3
A4
E
( )
*
Technical room
PL
Technical room Technical room
A1=A2=A3=A4= 80m.
G1=G2=G3=G4= 80m.
Note:
( )
1
Notes:
-For more informatio see characteristics, page 3.
Ports PoE
SWITCH
Cqmera IP/PoE
DQ-IPCAM
Technical room
Building 3
With DQ-IPCAM up to 3
inners door panels as in
the building 1.
Guard Monitor
ART 7W
ART 7W ART 7W ART 7W ART 7W ART 7W ART 7W ART 7W
( )
2
( )
2Note: DQ-IPCAM unit,
counts as 1 door panel.
( )
3
UNIDAD
DQ-IPCAM
Building 4
With DQ-IPCAM up to 3
inners door panels as in
the building 1.
( )
3DQ-IPCAM unit installation (Building 1):
DPM-G2+
SWITCH
DQ-IPCAM
( )
2
A1
A2 A3 A4
Technical room
Building 2
With DQ-IPCAM up to 3
inners door panels as in
the building 1.
-For description, installation, configuration and programming of
door panels and monitors, see the corresponding manuals.
Up-Link
Ports
Ports PoE
Camera IP/PoE
Up-Link
Ports
( )
4( )
4( )
4( )
4
Important: RD-G2+ modules must be V.03 or later
(compatibility with guard monitor and DQ-IPCAM).
( )
4
DQ-IPCAM G2+ IP CAMERAS UNIT
INSTALLATION MODES OF THE DQ-IPCAM G2 + CAMERA UNIT
1 2 3
ON DIP
45678
Building1
Block mode
End of line OFF
RD-G2+ configuration DIP switches:
1 2 3
ON DIP
45678
Building 2
Block mode
End of line OFF
1 2 3
ON DIP
45678
Building 3
Block mode
End of line OFF
1 2 3
ON DIP
45678
Building 4
Block mode
End of line ON
General
door panels

7
DESCRIPTION OF THE DQ-IPCAM G2+ IP CAMERAS UNIT
Description:
TOP
BOTTOM
a.
b.
c.
d.
e.
Label.
Not use.
Status led1 (green).
Standby led (on).
Starting/ resetting led (fast blink).
Previewing IP camera IP led (slow blink).
Status led2 (red).
Standby led (on).
Configuring IP camera led (slow blink).
Reset button (press for 3 seconds):
Reset all IP channel and IP address.
RJ-45 connector (UTP cable).
USB connector (connect Mouse, see page 11).
Conector HDMI (connect display, see page 11).
Golmar use.
Not use.
Not use.
DIN rail latch release.
Golmar use.
Switch mod (Leave left position).
G2+ Bus connection terminals.
G2+ Bus connection terminals.
f.
g.
h.
i.
j.
k.
l.
m.
n.
o.
p.
The DQ-IPCAM G2+ unit can be mounted onto a
DIN rail (8 elements) by applying slight pressure.
To remove the DQ-IPCAM G2+ unit from the DIN
rail, use a flat screwdriver to lever it off, as shown in
the drawing.
Install the DQ-IPCAM G2+ unit in a dry protectedlocation free from the risk of dripping or splashing water.
DIN 46277
INSTALLATION
Illustration of DQ-IPCAM G2+ IP CAMERAS UNIT:
a
Note: See installation diagrams for wiring.
( )
*
ON
1
2
3 4
RJ45
Adapter
DC 12V 1A
DIP SWITCH
Micro SD
Card slot
LED1
LED2
RESET
Mode
12458990 V01
Switch
CAMERA UNIT DQ-IPCAM-G2+
GOLMAR S.A.
C/ Silici, 13
08940-SPAIN
MADE IN CHINA
USB HDMI
BUS
BUS
FRONT
b
c
d
e
fghh i j
m
kln o
kn o p
p
ON
1
2
3 4
RJ45
Adapter
DC 12V 1A
DIP SWITCH
Micro SD
Card slot
LED1
LED2
RESET
Mode
12458990 V01
Switch
CAMERA UNIT DQ-IPCAM-G2+
GOLMAR S.A.
C/ Silici, 13
08940-SPAIN
MADE IN CHINA
USB HDMI
BUS
BUS
DQ-IPCAM G2+ IP CAMERAS UNIT

8
INSTALLATION
Setting the IP address(es) of the IP camera(s):
The IP address of the IP camera installed in the building must be configured and have the same network segment as
the DQ-IPCAM G2+ unit (see page 11). If there is more than one IP camera, you must change the address of the IP
cameras by connecting and configuring them one by one on the switch. Important: There cannot be more than one
IP camera with the same IP address connected to the switch.
Note: The detailed software is the “ ” to configure the addresses of the Golmar IP cameras.Device Config Tool
Connect a UTP RJ45 cable to a computer (with the "Device Config tool" software installed, see mini CD enclosed
with the IP camera) and the other end of the cable connect it to the switch (the picture below is a switch with ports
PoE and a Golmar IP/PoE camera).
Continued overleaf
UTP
UTP
SW-104
POE UP-LINK
1 2 3 4 5-UP 6-UP
S
V
P
V
N S
UP-LINK
PORTS
PoE
SW-104
Golmar IP/PoE Camera
Then open the "Device Config tool" program and click on the "Search" option.
DQ-IPCAM G2+ IP CAMERAS UNIT
PORTS

9
Change the IP address of the camera and make sure that the network segment of the IP camera is the same as the
DQ-IPCAM G2+ unit (see page 11). Then click on the "Modify" option to change the new IP address of the IP
camera (e.g. 192.168.1.2).
Continued from previous page.
Click on the IP camera line to edit.
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued overleaf
INSTALLATION
Setting the IP address(es) of the IP camera(s):

Important:
-If there is more than one IP camera installed in the building, it must be connected and configured one by one to the
switch to change the IP address of the camera.
-There cannot be more than 1 IP camera with the same IP address connected to the switch.
- Please refer to the manual supplied with the IP camera for the factory default IP address.
The new IP camera address will then be displayed.
192.168.1.2
10
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued from previous page.
INSTALLATION
Setting the IP address(es) of the IP camera(s):

11
Setting of DQ-IPCAM G2+ unit: (Local mode)
Mouse
ON
1
2
3 4
RJ45
Adapter
DC 12V 1A
DIP SWITCH
Micro SD
Card slot
LED1
LED2
RESET
Mode
12458990 V01
Switch
CAMERA UNIT DQ-IPCAM-G2+
GOLMAR S.A.
C/ Silici, 13
08940-SPAIN
MADE IN CHINA
USB HDMI
BUS
BUS
Display
Connect the DQ-IPCAM unit to the display with an HDMI cable and turn on the display. To access the main menu
click on the right mouse button and select the "Main menu" option.
To access the IP address of the DQ-IPCAM G2+ unit click on Setting--Network--Base--IP address and edit if there is
more than one DQ-IPCAM unit (installation of general boards and indoor buildings). To modify the IP address of the
second DQ-IPCAM unit (default: 192.168.1.200) and keeping the same network range would be "192.168.1.201",
then with the third one "192.168.1.202",.... Remember: If there is more than one DQ-IPCAM unit in the installation,
you must connect and configure one at a time to the switch to modify the IP address of the DQ-IPCAM unit. There
cannot be more than 1 DQ-IPCAM unit with the same IP address, (see features page 3).
UTP
SW-104
POE UP-LINK
1 2 3 4 5-UP 6-UP
S
V
P
V
N S
PORTS
UP-LINK
PORTS
PoE
SW-104
UTP
DQ-IPCAM unit
Golmar IP/PoE Camera
Main
100~240Vca
BUS (M) BUS (PL)
FA-G2+
LN
To door panelTo monitors
HDMI
192 . 168 . 1 . 200
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued overleaf
INSTALLATION

12
Access Channel -- IP Channel.
Click on the "Search" option, the connected IP cameras will be displayed. Then click on the IP camera to be
configured. Important: The IP addresses of the IP cameras must be configured (see pages 8-10).
INSTALLATION
Select the "Channel" and the IP camera to be linked and click on the "Add" option, enter the password of the camera
(admin) in the "Password" field and click on the "OK" option to confirm.
ONVIF 192.168.1.2 --
Search
192.168.1.2
admin
ONVIF
Add
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued from previous page.
Continued overleaf

13
ONVIF 192.168.1.2 --
192.168.1.2 ONVIF
The IP camera is already linked and connected. To view the IP camera image, click the right mouse button (see page 14).
Click on System--General to configure parameters of date/time, language, etc..., click on the "Apply" option to
confirm.
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued from previous page.
Continued overleaf
INSTALLATION

14
Press the right mouse button to select the display mode of the installed IP cameras.
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued from previous page.
INSTALLATION

Setting of DQ-IPCAM G2+ unit: (Web browser mode)
Before inserting the IP of the DQ-IPCAM unit in the web browser, we must make sure that the network connection of
our computer is in the same range as the IP of the DQ-IPCAM unit (by default "192.168.1.200"). To do this, follow
the steps below:
UTP
UTP
SW-104
POE UP-LINK
1 2 3 4 5-UP 6-UP
S
V
P
V
N S
PORTS
UP-LINK
PORTS
PoE
SW-104
ON
1
2
3 4
RJ45
Adapter
DC 12V 1A
DIP SWITCH
Micro SD
Card slot
LED1
LED2
RESET
Mode
12458990 V01
Switch
CAMERA UNIT DQ-IPCAM-G2+
GOLMAR S.A.
C/ Silici, 13
08940-SPAIN
MADE IN CHINA
USB HDMI
BUS
BUS
UTP
DQ-IPCAM
Golmar IP/PoE camera
Main
100~240Vac
BUS (M) BUS (PL)
FA-G2+
LN
To door panelTo monitors
https://192.168.1.200/index.html
192.168.1.200
admin
888999
It also allows setting by a web browser (Firefox, Chrome, Explorer...).
In installations with a PoE Switch and Golmar IP/PoE cameras, connect the computer to an UP-LINK port, as shown
below:
Step 1: Go to "Network & Internet" in windows settings.
15
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued overleaf
INSTALLATION

16
Step 2: Click on the "Change adapter options".
Step 3: Click twice on the active Ethernet connection.
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued from previous page.
Continued overleaf
INSTALLATION
1 elemento

17
Step 5: In the Ethernet properties window, Click twice and access the "Internet Protocol version 4 (TCP/IPv4)".
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued from previous page.
Continued overleaf
INSTALLATION
1 item
172 . 16 . 0 . 2
172 . 16 . 0 . 1
Cambiar la dirección IP
por ejemplo: “192.168.1.250"
Cambiar la dirección IP
por: “192.168.1.1"
Confirmar configuración
1 elemento
Step 4: In the Ethernet status window, click on the "properties".
1 item

18
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued from previous page.
Continued overleaf
INSTALLATION
Step 6: Set the IP range in the "Internet Protocol version 4 (TCP/IPv4) Properties" window, with the same IP
range of the DQ-IPCAM unit (default "192.168.1.200").
The network connection of the computer is already configured in the same range as the IP of the DQ-IPCAM unit.
Then open the web browser (Firefox, Chrome, Explorer...) and insert the IP of the DQ-IPCAM unit (by default
"192.168.1.200").
Insert the IP in the web browser: Insert user & password:
192.168.1.200 192.168.1.200
admin
888999
DQ-IPCAM/G2+
User Name
Password
IP DQ-IPCAM Unit (by default):192.168.1. 200 User: admin Password: 888999
1 item
172 . 16 . 0 . 2
172 . 16 . 0 . 1
Change IP address
e.g: “192.168.1.250"
Change IP address
by: “192.168.1.1"
Click on the “OK” option
to corfirm
Internet protocol version 4 (TCP&IPv4) Properties

19
It is necessary to modify the IP address of the DQ-IPCAM unit (default: 192.168.1.200) if there is more than one DQ-
IPCAM unit (installation of general boards and indoor buildings). To modify the IP address of the second DQ-
IPCAM unit and keeping the same network range would be "192.168.1.201", then with the third one
"192.168.1.202",....
Remember: If there is more than one DQ-IPCAM unit in the installation, you must connect and configure one at a
time to the switch to modify the IP address of the DQ-IPCAM unit.
There cannot be more than 1 DQ-IPCAM unit with the same IP address.
To access the IP address of the DQ-IPCAM G2+ unit, click on Set--Network--IP address; and edit/change the IP
address (if there is more than one unit) of the DQ-IPCAM G2+ unit (default value: 192.168.1.200).
200
(2nd DQ-IPCAM unit)
Change the IP address
for example: "192.168.1.201".
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued from previous page.
Continued overleaf
INSTALLATION

Access Channel--Digital Channel.
Click on the "Search" option, the connected IP cameras will be displayed. Important: The IP addresses of the IP
cameras must be configured (see pages 8-10).
Select the "Channel" and the IP camera to be linked and click on the "Add" option.
20
192.168.1.2
DQ-IPCAM G2+ IP CAMERAS UNIT
Continued from previous page.
Continued overleaf
INSTALLATION
Other manuals for G2+
9
Table of contents
Other golmar Control Unit manuals
Popular Control Unit manuals by other brands

Burkert
Burkert 6407 operating instructions

Sleipner
Sleipner PPC520 user manual

Crestron
Crestron C2N-FTB Operations & installation guide

Task Force Tips
Task Force Tips Twister Instructions for installation, safe operation and maintenance

Stübbe
Stübbe K 210 Series operating manual

Resol
Resol DeltaSol MX manual