golmar M-IP-GB2 User manual

USER MANUAL
Code 50122106 T G ENM-IP- B2 REV. 9011
M-IP-GB2 Memory
Module
GB2 Nexa Modular
2-Wire Installation
Video/photo memory module.
TECHNOLOGY

-Do not overtighten the screws on the Bus connection terminals of the M-IP-GB2 module.
-Before connecting the device to the mains, check the connections of the M-IP-GB2 module, FA-GB2/B power supply,
distributors and monitors.
-Use the Golmar cable (2x1mm ).RAP-2150 2
-Always follow the instructions contained in this manual.
CHARACTERISTICS
INTRODUCTION
First of all, we thank and congratulate you for purchasing this product.
Our commitment to achieving the satisfaction of customers like you is manifested through our ISO-9001 certification
and the manufacture of products like the one you have just purchased.
Its advanced technology and strict quality control will ensure that customers and users enjoy the numerous features
that this device offers. To get the most out of them and ensure proper operation from day one, we recommend that
you read this instruction manual.
CONTENTS
2
SET-UP WARNINGS
I .................................................................................................................................................................2ntroduction
Contents.................................................................................................................................................................... 2
Set-up warnings................................................................................................................... ..... .. 2............................. .. .
Description of terminals...................................................................................................................................... ...... 3. ..
Mounting.................................................................................................................................................................... 3.
Operating mode.................................................................................................................................. ..... ..4............ .....
Connections diagram........................................................................................................................................ ... 5...... .
MEMORY MODULE: M-IP-GB2
Date/time setting...................................................................................................................................................... .6. .
-M-IP-GB2 memory module with simplified wiring (non-polarised 2-wire bus).
-M-IP-GB2 memory module for the GB2 system:
w'Building' installation:
-Up to 1 M-IP-GB2 memory unit.
-The memory unit must be installed on the monitors Bus side (see wiring diagram p. 5).
-Each apartment can only watch its own recordings.
-The system monitor must support the image recording function (videos/photos).
-When connected to the M-IP-GB2 unit, the photo memory and calendar function will be activated immediately; for the
video memory function, a 16 GB Class 10 MicroSD card (not included) is required.
-The system monitor must support the image recording function.
-The monitor has an auto-recording function.
-The time for each video recording in the memory module is 9 seconds (16 GB Class 10 MicroSD card required).
-Recorded videos/photos can be deleted from the monitor.
-Videos/photos can be played on the monitor if the system is in standby. If a call is received while a video/photo is being
viewed, playback will be interrupted to enable the call to be answered immediately.
-In building systems, each apartment can only watch its own recordings.
-It is recommended to check the videos/photos of missed calls stored and delete any old ones.
SAFETY PRECAUTIONS
-Always disconnect the power supply before installing or making modifications to the device.
-The fitting and handling of these devices must be carried out by authorised personnel.
-The wiring must run at least .40cm away from any other wiring
-Install the module in a dry protected location free from the risk of dripping or splashing water.
-Do not place in humid, dusty or smoky locations, or near sources of heat.
-Ensure that the air vents are free from obstruction so that air can circulate freely.
-To prevent damage, the M-IP-GB2 module must be firmly secured in place.
Safety precautions.................................................................................................................................. ........ 3........... .
Notes ................. 7........................................................................................................................................................ .

No function
BUS(M)
Micro SD card
(Max. 16GB
Class 10)
MEMORY MODULE: M-IP-GB2 3
DESCRIPTION OF TERMINALS
1 2 3 4 5 6
ON
BUS(DS)
DIP switches (leave in the OFF position), NO FUNCTION
BUS (DS): Bus input terminals.
Table1
1 2 3 4 5 6
Posi ntio
DIP1~DIP6
Status Descrip ntio
MOUNTING
DIN rail
DIN rail
Mounting tab
Step 1: Install the DIN rail on the wall, securing it
with the screws supplied.
Step 2: Pull the mounting tab, then lightly press
the unit against the wall.
NOTE: Before connecting the M-IP-GB2 module, disconnect the system's power supply.
BUS (M): Bus output terminals.
LAN
LAN: No function.
Front
Top part Bottom part

MEMORY MODULE: M-IP-GB2 4
-Not used
-Not used
-Not used
IP-CHK -Not used
-LED blinking, initialising system, approx 15 seconds.
Power
LED BUTTONS
In-use
Net Video
CHECK CALL
DT-CHK IP-CHK
LED indicator Descrip ntio
POWER -LED fixed, status OK.
LIGHT -Not used
MEMORY -Not used
CAMERA -Not used
BUTTONS Descrip ntio
CHECK
CALL
DT-CHK
OPERATING MODE
Description of the status LEDs:
Electrical resistance of the conductor at 20°C
ELECTRICAL CHARACTERISTICS
19,5 /Km
Capacity between conductors
Characteristic impedance
VALUES
45pf/m 10%
100 10%
RAP-2150 (GOLMAR) CABLE CHARACTERISTICS
Flexible 1mm twisted pair polished copper conductor
2
CONSTRUCTION CHARACTERISTICS
Class V
VALUES
15 V/m
Wiring
Description of the buttons:

MEMORY MODULE: M-IP-GB2 5
WIRING DIAGRAM:
Access panel
Mains
100~240Vac
N L
CN
BUS (M) BUS(PL)
FA- 2 BGB /
L
or
BUS BUS
BUS BUS
D2D1
D2L-GB2
End of
line
ON
BUS BUS
BUS BUS
D2D1
D2L- 2GB
APARTMENT 2
APARTMENT 1
OFF
(1)
(1)
( )3
**
( )
*
( )
BUS
BUS
( )3
**
( )
( )3
**
( )( )3
**
( )
VESTA2 SE
Master
( )3
**
( )
BUS
( )3
**
( )
APARTMENT 23
Video door entry system building installation with M-IP-GB2 image module.
AP
(2)
NA2
+AP-
C1 NA1 AP+ C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
ON
1 2 3 4 5 6
SW1
Coded panel
(2)
Button panel
Configure the end of line in
the last monitor.
DIP 6 to On.
Remove the jumper from all
of the distributors except
the last.
**
( )
*
( )
Place the jumper in the GB2 monitors position of all of the D2L-GB2 distributors.
(1)
( )2 For the connection of an AC lock release or a 2nd lock release, see the manual supplied with the door panel.
For description, installation, configuration, distances, cross-sections and programming of the monitor and door panel, see the
corresponding manual.
( )3
Important:
Button building
mode
or
Coded building
mode
12 Vdc / 270mA
( )3
VESTA2 SE
Master
(DS) (M)
M IP- -GB2
BUS BUS
VESTA2 SE
Master
End of
line

To change the date and time displayed on recorded videos/photos, press in the VESTA2 SE monitor menu and use
the and buttons to go to the 'Settings' option. Press once in the 'Settings' menu, keep the button pressed
for 3 seconds and then set the date and time. (See details of how to set the date and time below).
Ring olumeV
Autoswitch imeON T
Ring neTu
Settings
Language
Light
About
Divert
Settings
Main menu
MEMORY MODULE: M-IP-GB2 6
201 - -9 04 29
Date time&
1 : :0 51 40
DATE/TIME SETTING
Main menu
Camera/Door
Intercom
Playback
Do not disturb
1 / /0 1 : : 18 11 7 0 52 0
With the monitor showing the 'Date time' settings screen,&
press the button to move around the date/time and use
the and buttons to change the values. Press option to
save and then press option to exit the user menu function.

NOT S:E
MEMORY MODULE: M-IP-GB2 7

golmar@golmar.es
www.golmar.es
Sistemas de comunicación S.A.
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.
GOLMAR S.A.
C/ Silici, 13
08940- Cornellá de Llobregat
SPAIN
Table of contents
Other golmar Control Unit manuals
Popular Control Unit manuals by other brands

Cartell
Cartell DRIVEGUARD ULTRA Installation & operation manual

ThermOmegaTech
ThermOmegaTech CircuitSolver CSUTD-D-PX installation instructions

Tormatic
Tormatic HmIP-MOD-TM manual

Emerson
Emerson SEMPELL Installation and maintenance instructions

Skov
Skov BlueControl Insect Technical user guide

Giacomini
Giacomini R401TG manual