Kurzbedienungsanleitung
Short-form Operating Instructions
METRA
HIT
⏐
ULTRA
High Resolution
TRMS System Multimeter 3-349-685-15
4/5.17
Lieferumfang
1 Multimeter
1 Messkabelsatz KS17-2
2 Mignonzellen
1 DAkkS-Kalibrierschein
1 Gummischutzhülle
1 Kurzbedienungsanleitung
– Ausführliche Bedienungsanleitungen (D und GB) im Internet
zum Download unter www.gossenmetrawatt.com
Standard Equipment
1 Multimeter
1 Set of measuring cables KS17-2
2 AA size batteries 1.5 V
1 DAkkS calibration certificate
1 Protective rubber holster
1 Short-form Operating Instructions
– Detailed operating instructions (D and GB) for download
on the Internet at www.gossenmetrawatt.com
Sicherheitshinweise
Um den einwandfreien Zustand des Gerätes zu
erhalten und die gefahrlose Verwendung sicherzu-
stellen, müssen Sie vor dem Einsatz Ihres Gerätes die Bedie-
nungsanleitung sorgfältig und vollständig lesen und in allen
Punkten befolgen.
Beachten Sie folgende Sicherheitsvorkehrungen:
Das Multimeter darf nicht in Ex-Bereichen eingesetzt werden.
Das Multimeter darf nur von Personen bedient werden, die in
der Lage sind, Berührungsgefahren zu erkennen und Sicherheits-
vorkehrungen zu treffen. Berührungsgefahr besteht überall, wo
Spannungen größer als 33 V AC (Effektivwert) bzw. 70 V DC
auftreten.
Die maximal zulässige Spannung lt. Norm zwischen den
Spannungsmessanschlüssen bzw. allen Anschlüssen gegen
Erde beträgt 600 V in der Messkategorie CAT III bzw. 300 V in der
Messkategorie CAT IV.
Nur mit der auf der Prüfspitze der Messleitung aufgesteckten Sicher-
heitskappe dürfen Sie nach DIN EN 61010-031 in einer Umgebung nach
Messkategorie II I oder IV messen.
Für die Kontaktierung in 4-mm-Buchsen müssen Sie die Sicher-
heitskappen entfernen, indem Sie mit einem spitzen Gegen-
stand (z. B. zweite Prüfspitze) den Schnappverschluss der
Sicherheitskappe aushebeln.
Achtung: An defekten Geräten, Kondensatoren, ... können
unvorhergesehene Spannungen auftreten!
Die Isolation der Messleitungen darf nicht beschädigt sein und
Leitungen, bzw. Stecker dürfen keine Unterbrechung aufweisen!
In Stromkreisen mit Koronaentladung (Hochspannung) dürfen
Sie nicht messen!
Seien Sie besonders vorsichtig beim Messen in
HF-Stromkreisen mit gefährlichen Mischspannungen!
Messungen bei feuchten Umgebungsbedingungen sind nicht
zulässig!
Überlasten Sie die Messbereiche nicht mehr als zulässig!
Der Eingang der Strommessbereiche ist mit einer Schmelzsicherung
ausgerüstet. Verwenden Sie nur Original-Schmelzsicherungen, siehe
Gehäuseaufdruck oder Technische Daten!
Betreiben Sie das Gerät nur mit eingelegten Batterien oder Akkus. Gefährli-
che Ströme oder Spannungen werden sonst nicht signalisiert und Ihr Gerät
kann beschädigt werden.
Das Gerät darf nicht mit entferntem Sicherungs- oder Batteriefachdeckel
oder geöffnetem Gehäuse betrieben werden.
Safety Instructions
In order to maintain the flawless condition of the
instrument, and to ensure its safe operation, it is
imperative that you read the operating instructions thoroughly and
carefully before placing your instrument into service, and that you
follow all instructions contained therein.
Observe the following safety precautions:
The multimeter may not be used in potentially explosive atmospheres.
The multimeter may only be operated by persons who are able to
recognize contact hazards and take the appropriate safety precau-
tions. Contact hazards exist wherever voltages of more than
33 V AC (RMS value) and/or 70 V DC occur.
The
maximum allowable voltage
according to standard between the
voltage measuring inputs or all inputs towards ground is equal to
600 V, category III or 300 V, category IV, respectively.
In conformity with standard DIN EN 61010-031, measurements in an
environment according to measuring category II I or IV may only be per-
formed with the safety cap applied to the test probe of the measure-
ment cable.
For establishing contact in 4 mm jacks you have to remove the
safety cap by levering out the snap lock of the safety cap with
another sharp object (e.g. the second test probe).
Attention:
Unexpected voltages may occur at defective devices,
capacitors,...!
The insulation of the measurement cables may not be damaged,
cables and plugs may not be interrupted!
No measurements may be made in electrical circuits with corona
discharge (high-voltage)!
Special care is required when measurements are performed in HF elec-
trical circuits where dangerous pulsating voltages may be present.
Measurements under moist ambient conditions are not permissible.
Do not overload the measuring ranges beyond their allowable
capacities!
The input of the current measuring ranges is fitted with a fuse. Use
original fuses only, see label on the housing or technical data section!
Only operate the instrument with batteries or storage batteries inserted.
Otherwise dangerous currents or voltages will not be indicated and your
instrument may be damaged.
The device may not be operated with the fuse or battery com-
partment lid removed or with open housing.
Leistungsumfang – Overview of Features included
1)
16 MBit = 2048 kByte = max.
300000
Messwerte
Measured values
,
Speicherrate einstellbar zwischen 0,1 s und 9 h
,
sampling rate adjustable from 0.1 s to 9 h
Elektrische Sicherheit – Electrical Safety
Schutzklasse / Safety class II
– nach /
per
IEC 61010-1:2010/EN 61010-1:
2010
/VDE 0411-1:
2011
Messkategorie / Measuring Category:
CAT IV / CAT III
Nennspannung / Nominal Voltage 300 V / 600 V
Verschmutzungsgrad / Pollution degree 2
Prüfspannung / Test Voltage 5,2 kV~
– nach / per IEC 61010-1/EN 61 010-1
Schutzart / Protection – Gehäuse / Housing:
IP52 (Druckausgleich durch Gehäuse/
pressure equalization by means of the housing;
Tabellenauszug zur Bedeutung des IP-Codes
Extract from table on the meaning of IP codes
Anwendung Messkabelsatz – Application of measuring cable set KS17-2
Bitte beachten Sie die Maximalwerte der elektrischen Sicherheit des
Messgeräts.
Please observe the maximum values of the electrical safety of the device.
Elektromagnetische Verträglichkeit EMV
Electromagnetic Compatibility EMC
Störaussendung / Interference Emission
EN 61326-1: 2006 Klasse B / class B
Störfestigkeit / Interference Immunity
EN 61326-1:
2006
EN 61
326
-2-1: 2006
Umgebungsbedingungen – Ambient Conditions
Genauigkeitsbereich / Accuracy range 0 °C ... + 40 °C
Arbeitstemperatur / Operating temperature –10 °C ... + 50 °C
Lagertemperatur / Storage temperature
ohne Batterie / without battery – 25 °C ... + 70 °C
relative Luftfeuchte / relative humidity 40 ... 75 %
Betauung ist auszuschließen / no condensation allowed
Höhe über NN bis zu / Elevation up to 2000 m maximum
Sicherung – Fuse
FF(ultrarapid) 10 A/1000 V AC DC
10 mm x 38
Abschaltleistung / breaking capacity:
30 kA
Bei Einsatz einer anderen Sicherung erlischt die Herstellergarantie.
If you use other fuses than the one indicated above you forfeit
your manufacturer’s guarantee.
Interner Sicherungstest –
Internal Fuse Test
Sicherungstausch – Fuse Replacement
Trennen Sie das Gerät vom Messkreis bevor Sie den
Sicherungsdeckel öffnen! Drehen Sie hierzu die
(unverlierbare) Schlitzschraube entgegen dem Uhrzei-
gersinn. Hebeln Sie die Sicherung mit der flachen
Seite des Sicherungsdeckels heraus.
Beim Wiedereinsetzen des Sicherungsdeckels muss die Seite
mit den Führungshaken zuerst eingesetzt werden.
Drehen Sie die Schlitzschraube im Uhrzeigersinn ein.
Disconnect the instrument from the measuring circuit
before opening the fuse compartment lid! Turn the
(captive) slotted head screw counter-clockwise for
this purpose. Remove the fuse with the flat end of the
fuse compartment lid.
When refitting the fuse compartment lid the side with the guide
hooks must be inserted first. Then turn the slotted head screw
clockwise.