Grant's Automation MAW6 Quick start guide

Wiring Diagram and Programming
Instructions for
MAW6 Digital Keypad
and Proximity Card/F reader
www.grantsautomation.com.au - [email protected]
Wiring Diagrams for MAW6 Digital Keypad
Maw-6 Digital Keypad/Touch Tag Reader
Buzz-A - Pink
Buzz-B - Pale
Blue
WG DO - Green
WG D1 - White
Alarm - Grey
Exit P/B - Yellow
Door In - Brown
9 to 28VDC+ - Red
Ground - Black
NO - Blue
COM - Purple
NC - Orange
12VDC Power Supply
Can be unregulated with an output
between 9V and 28VDC
+
-
Exit
Exit Button will activate
the Devices output timer
in the same manner
that entering a correct
code or touching a
programmed tag or card
does. Ideal as a way
for pedestrians to exit
without a code.
‘Door In’ is for a mag-
netic reed or micro
switch tted to a gate to
activate an alarm if not
closed in 1 minute after
use.
For Pedestrian Gates tted with an electric
Strike Lock or magnetic Lock
Electric Strike
Lock 12VDC
Magnetic
Lock 12VDC
+
+
-
-
Maw-6 Digital Keypad/Touch Tag Reader
Buzz-A - Pink
Buzz-B - Pale
Blue
WG DO - Green
WG D1 - White
Alarm - Grey
Exit P/B - Yellow
Door In - Brown
9 to 28VDC+ - Red
Ground - Black
NO - Blue
COM - Purple
NC - Orange
For 12V Automatic Gate Operator or 240V Operator with 12VDC output for accessories.
Automatic Gate Operator
Control Board
P/B in
12V+ out
Ground
P/B com
Door
Alarm
-+
Maw-6 Digital Keypad/Touch Tag Reader
Bell-A - Pink
Bell-B - Pale Blue
WG DO - Green
WG D1 - White
Alarm - Grey
Exit P/B - Yellow
Door In - Brown
9 to 28VDC+ - Red
Ground - Black
NO - Blue
COM - Purple
NC - Orange
Access Control/Alarm
D0
D1
12V+ out
Ground
Door
Bell
Alarm
-+
For Access Control/Alarms system
Wiring Diagrams for MAW6 Digital Keypad
Maw-6 Digital Keypad/Touch Tag Reader
Buzz-A - Pink
Buzz-B - Pale Blue
WG DO - Green
WG D1 - White
Alarm - Grey
Exit P/B - Yellow
Door In - Brown
9 to 28VDC+ - Red
Ground - Black
NO - Blue
COM - Purple
NC - Orange
For 24V Automatic Gate Operator or 240V operator with 24VAC or DC output for accessories.
Automatic Gate Operator
Control Board
P/B in
24V~ out
Ground
P/B com
VC-12V
Voltage Converter
24V~ in
12V+ out
Ground
Programming Instructions for MAW6 Digital Keypad and Card reader
FEATURES:
• Up to 2000 User Codes (4 Digits), touch tags or cards all with a seperate user ID number so they
can be removed even if tag or card is lost or code is forgotten. Note: need to keep a log book
• Can use Code or Tag/Card or Code + Tag/Card for extra security
• Activation time from 0 to 99 seconds.
• Users can change their own Code or Card without Master Code
• Keypads give a visual as well as acoustic signaling while entering codes
PROGRAMMING:
Enter “ <Master Code># ”
Factory code “ 999-999 ”
press “ 1 ”
RED LED goes YELLOW
*
To Add a User Code or
Tag/Card by ID
Enter “<User ID Number>#”
1 to 2000
will ‘beep beep beep’ if this
user already has a code or
card
To Remove a User Code
or Tag/Card by ID
Do
you want to
Add more?
No
Yes
Do
you want to
remove more?
No
Yes
www.grantsautomation.com.au - [email protected]
Enter “<User Code>#”
(4 digits) or Swipe Tag/Card
LED will go GREEN for 1/2
sec if Code or Card OK or
‘beep beep beep’ if not OK
press “ # ” then “ ” to exit
programming mode
*
press “ 2 ”
RED LED goes YELLOW
Enter “<User ID Number>#”
1 to 2000
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
press “ # ” then “ ” to exit
programming mode
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
Enter “ <Master Code># ”
Factory code “ 999-999 ”
press “ 1 ”
RED LED goes YELLOW
*
To Add many Tags/
Cards
Do
you want to
Add more?
No
Yes
Swipe Tag/Card
LED will go GREEN for 1/2
sec if Tag/Card OK or ‘beep
beep beep’ if not OK
press “ # ” then “ ” to exit
programming mode
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
To Remove all User
Codes or Tags/Cards
press “ 20,000 # ”
press “ # ” then “ ” to exit
programming mode
*
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
www.grantsautomation.com.au - [email protected]
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
PROGRAMMING:
To Remove a Tag/Card
with Tag/Card
Do
you want to
remove more?
No
Yes
press “ 2 ”
RED LED goes YELLOW
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
press “ # ” then “ ” to exit
programming mode
*
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
Swipe Tag/Card
Set Tag/Card only Option
press “ 30 # ”
press “ # ” then “ ” to exit
programming mode
*
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
Set Tag/Card & Code
Option
press “ 31 # ”
press “ # ” then “ ” to exit
programming mode
*
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
Set Tag/Card OR Code
Option (default)
press “ 32 # ”
press “ # ” then “ ” to exit
programming mode
*
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
To Change Activation
Time
Enter time in seconds from
0 to 99
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
press “ 4 ”
RED LED goes YELLOW
YELLOW LED goes
GREEN for 1/2 sec if OK or
beep beep beep if not OK
press “ # ” then “ ” to exit
programming mode
*
Enter “ <User ID Number>#”
*
To Change a User Code
Enter <old User Code> #
RED LED goes YELLOW
YELLOW LED goes
GREEN for 1/2 sec if OK or
beep beep beep if not OK
RED ashing LED goes green
for 1/2 sec. then RED no ash
Enter “<new User Code>#”
(4 digits)
Enter “<new User Code>#”
(4 digits) to conrm
press “ # ” then “ ” to exit
programming mode
*Record Master Code Here:
Programming Instructions for MAW6 Digital Keypad
To Change the Master Code
Record User ID numbers and Codes Here:
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
press “ 0 ”
RED LED goes YELLOW
YELLOW LED goes
GREEN for 1/2 sec if OK or
beep beep beep if not OK
Enter “<new Master Code>#”
(6 to 8 digits)
Enter “<new Master Code>#”
(6 to 8 digits) to conrm
press “ # ” then “ ” to exit
programming mode
*
User Name and/or Description User ID Number User Code
Restoring Factory Settings.
The factory settings can be recov-
ered it necessary without loosing
any user codes, tags or cards pro-
grammed in. To do this remove
power from the device, then after
15 seconds press and hold the “#’
key and restore power. When the
decive beeps left go of the “#” key
as the factory settings have been
restored.
www.grantsautomation.com.au - [email protected]

Popular Keypad manuals by other brands

Bosch AMAX 2100 installation guide

Bosch

Bosch AMAX 2100 installation guide

Intratone 04-0107 quick start guide

Intratone

Intratone 04-0107 quick start guide

Raymarine SeaTalk Owner's handbook

Raymarine

Raymarine SeaTalk Owner's handbook

Elko iNels RF KEY - 40 quick start guide

Elko

Elko iNels RF KEY - 40 quick start guide

Ugo UKL-1074 user manual

Ugo

Ugo UKL-1074 user manual

Pyronix MATRIX Installation instruction

Pyronix

Pyronix MATRIX Installation instruction

DSC PK5500 installation instructions

DSC

DSC PK5500 installation instructions

Retekess TD029 user manual

Retekess

Retekess TD029 user manual

Harman AMX MET-6N instruction manual

Harman

Harman AMX MET-6N instruction manual

MIOTTA KYP1300 quick start guide

MIOTTA

MIOTTA KYP1300 quick start guide

ANXELL E-Access E3AK Series instructions

ANXELL

ANXELL E-Access E3AK Series instructions

CADDX Ranger 9050 installation manual

CADDX

CADDX Ranger 9050 installation manual

Risco Agility 132KP instruction manual

Risco

Risco Agility 132KP instruction manual

Auta 721159 manual

Auta

Auta 721159 manual

AAP KP-ICON OEM user guide

AAP

AAP KP-ICON OEM user guide

Nice EDSWG quick start guide

Nice

Nice EDSWG quick start guide

Vimar ELVOX 13F4 Installer's guide

Vimar

Vimar ELVOX 13F4 Installer's guide

Arrowhead KP600F/KP600L owner's manual

Arrowhead

Arrowhead KP600F/KP600L owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.