Grant's Automation MAW6 Quick start guide

Wiring Diagram and Programming
Instructions for
MAW6 Digital Keypad
and Proximity Card/F reader

Wiring Diagrams for MAW6 Digital Keypad
Maw-6 Digital Keypad/Touch Tag Reader
Buzz-A - Pink
Buzz-B - Pale
Blue
WG DO - Green
WG D1 - White
Alarm - Grey
Exit P/B - Yellow
Door In - Brown
9 to 28VDC+ - Red
Ground - Black
NO - Blue
COM - Purple
NC - Orange
12VDC Power Supply
Can be unregulated with an output
between 9V and 28VDC
+
-
Exit
Exit Button will activate
the Devices output timer
in the same manner
that entering a correct
code or touching a
programmed tag or card
does. Ideal as a way
for pedestrians to exit
without a code.
‘Door In’ is for a mag-
netic reed or micro
switch tted to a gate to
activate an alarm if not
closed in 1 minute after
use.
For Pedestrian Gates tted with an electric
Strike Lock or magnetic Lock
Electric Strike
Lock 12VDC
Magnetic
Lock 12VDC
+
+
-
-
Maw-6 Digital Keypad/Touch Tag Reader
Buzz-A - Pink
Buzz-B - Pale
Blue
WG DO - Green
WG D1 - White
Alarm - Grey
Exit P/B - Yellow
Door In - Brown
9 to 28VDC+ - Red
Ground - Black
NO - Blue
COM - Purple
NC - Orange
For 12V Automatic Gate Operator or 240V Operator with 12VDC output for accessories.
Automatic Gate Operator
Control Board
P/B in
12V+ out
Ground
P/B com
Door
Alarm
-+

Maw-6 Digital Keypad/Touch Tag Reader
Bell-A - Pink
Bell-B - Pale Blue
WG DO - Green
WG D1 - White
Alarm - Grey
Exit P/B - Yellow
Door In - Brown
9 to 28VDC+ - Red
Ground - Black
NO - Blue
COM - Purple
NC - Orange
Access Control/Alarm
D0
D1
12V+ out
Ground
Door
Bell
Alarm
-+
For Access Control/Alarms system
Wiring Diagrams for MAW6 Digital Keypad
Maw-6 Digital Keypad/Touch Tag Reader
Buzz-A - Pink
Buzz-B - Pale Blue
WG DO - Green
WG D1 - White
Alarm - Grey
Exit P/B - Yellow
Door In - Brown
9 to 28VDC+ - Red
Ground - Black
NO - Blue
COM - Purple
NC - Orange
For 24V Automatic Gate Operator or 240V operator with 24VAC or DC output for accessories.
Automatic Gate Operator
Control Board
P/B in
24V~ out
Ground
P/B com
VC-12V
Voltage Converter
24V~ in
12V+ out
Ground

Programming Instructions for MAW6 Digital Keypad and Card reader
FEATURES:
• Up to 2000 User Codes (4 Digits), touch tags or cards all with a seperate user ID number so they
can be removed even if tag or card is lost or code is forgotten. Note: need to keep a log book
• Can use Code or Tag/Card or Code + Tag/Card for extra security
• Activation time from 0 to 99 seconds.
• Users can change their own Code or Card without Master Code
• Keypads give a visual as well as acoustic signaling while entering codes
PROGRAMMING:
Enter “ <Master Code># ”
Factory code “ 999-999 ”
press “ 1 ”
RED LED goes YELLOW
*
To Add a User Code or
Tag/Card by ID
Enter “<User ID Number>#”
1 to 2000
will ‘beep beep beep’ if this
user already has a code or
card
To Remove a User Code
or Tag/Card by ID
Do
you want to
Add more?
No
Yes
Do
you want to
remove more?
No
Yes
Enter “<User Code>#”
(4 digits) or Swipe Tag/Card
LED will go GREEN for 1/2
sec if Code or Card OK or
‘beep beep beep’ if not OK
press “ # ” then “ ” to exit
programming mode
*
press “ 2 ”
RED LED goes YELLOW
Enter “<User ID Number>#”
1 to 2000
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
press “ # ” then “ ” to exit
programming mode
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
Enter “ <Master Code># ”
Factory code “ 999-999 ”
press “ 1 ”
RED LED goes YELLOW
*
To Add many Tags/
Cards
Do
you want to
Add more?
No
Yes
Swipe Tag/Card
LED will go GREEN for 1/2
sec if Tag/Card OK or ‘beep
beep beep’ if not OK
press “ # ” then “ ” to exit
programming mode
*
RED ashing LED goes green
for 1/2 sec. then RED no ash

To Remove all User
Codes or Tags/Cards
press “ 20,000 # ”
press “ # ” then “ ” to exit
programming mode
*
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
PROGRAMMING:
To Remove a Tag/Card
with Tag/Card
Do
you want to
remove more?
No
Yes
press “ 2 ”
RED LED goes YELLOW
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
press “ # ” then “ ” to exit
programming mode
*
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
Swipe Tag/Card
Set Tag/Card only Option
press “ 30 # ”
press “ # ” then “ ” to exit
programming mode
*
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
Set Tag/Card & Code
Option
press “ 31 # ”
press “ # ” then “ ” to exit
programming mode
*
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
Set Tag/Card OR Code
Option (default)
press “ 32 # ”
press “ # ” then “ ” to exit
programming mode
*
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
LED will go GREEN for 1/2
sec if OK or ‘beep beep
beep’ if not OK
To Change Activation
Time
Enter time in seconds from
0 to 99
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
press “ 4 ”
RED LED goes YELLOW
YELLOW LED goes
GREEN for 1/2 sec if OK or
beep beep beep if not OK
press “ # ” then “ ” to exit
programming mode
*

Enter “ <User ID Number>#”
*
To Change a User Code
Enter <old User Code> #
RED LED goes YELLOW
YELLOW LED goes
GREEN for 1/2 sec if OK or
beep beep beep if not OK
RED ashing LED goes green
for 1/2 sec. then RED no ash
Enter “<new User Code>#”
(4 digits)
Enter “<new User Code>#”
(4 digits) to conrm
press “ # ” then “ ” to exit
programming mode
*Record Master Code Here:
Programming Instructions for MAW6 Digital Keypad
To Change the Master Code
Record User ID numbers and Codes Here:
Enter “ <Master Code># ”
Factory code “ 999-999 ”
*
RED ashing LED goes green
for 1/2 sec. then RED no ash
press “ 0 ”
RED LED goes YELLOW
YELLOW LED goes
GREEN for 1/2 sec if OK or
beep beep beep if not OK
Enter “<new Master Code>#”
(6 to 8 digits)
Enter “<new Master Code>#”
(6 to 8 digits) to conrm
press “ # ” then “ ” to exit
programming mode
*
User Name and/or Description User ID Number User Code
Restoring Factory Settings.
The factory settings can be recov-
ered it necessary without loosing
any user codes, tags or cards pro-
grammed in. To do this remove
power from the device, then after
15 seconds press and hold the “#’
key and restore power. When the
decive beeps left go of the “#” key
as the factory settings have been
restored.