4. To install in a square back box, push sensor
into back box and using two 3.5mm screws
secure to back box through the
appropriate mounting holes, refer to Dia:4.
Di :3 Di :4
3. To install in a circular back box, push
sensor in to box and tighten the two
splay screws, refer to Dia:3.
1. Slide function switch to the PIR position
(furthest right).
2. Turn ‘Time’ control fully anti-clockwise and
‘Lux’ control fully clock wise refer to Dia:5.
3. Re-connect mains supply, allow 30 seconds
for the sensor to warm-up, and then
perform a walk-by in front of the sensor;
lamp should turn on and stay on for
approximately 10 seconds, and will go off if
no further movement is detected.
TESTING
FUNCTION SWITCH
1. ‘ON’ position, light will be permanently on, and will ignore PIR control.
2. ‘OFF’ position, light will be permanently off, and will ignore PIR control.
3. ‘PIR’position, light will be controlled by the sensors PIR control.
TROUBLE SHOOTING
Light not coming on in PIR mode
•Fuse has blown, check fuse located under the front plate.
• Check that lamp is good.
• Check there is nothing obscuring the PIR sensor.
• Check that function switch is set to ‘PIR’.
Intermittent oper tion
• Check there are no curtains that can move in the wind.
• Check there are no heating vents nearby.
TECHNICAL INFORMATION
Rated Voltage: 230V~50Hz
IP Rating: IP20
Ambient Light: <3-2,000 LUX (Adj)
Time Delay: in 10 sec ± 3 sec
ax 7 min ± 2 min
Rated Load: 0W - 500W
5W - 200W
Detection Range: 160°
Detection Distance: 9 max (<24°C)
Working Temp: -20° - + 40°C
Working Humidity: <93%RH
Power Consumption: 0.5W approx
Installation Height: 1 - 1.8
Detection oving Speed: 0.6 - 1.5m/s
Fuse Type: 3A, 20mm X 5mm
Dimensions: 80 x 80 x 44.1mm
Di :5
/LED
ADJUSTING THE ‘LUX’ CONTROL
1. Turning Lux control fully clock wise, the sensor will operate in both daylight and darkness.
2. Turning Lux control fully anti-clockwise, the sensor will operate in darkness only.
3. Set control to operate at your required daylight level.
ADJUSTING THE ‘TIME ON’ CONTROL
1. Turning the time control fully anti-clock wise will set the on duration to 10 seconds +/- 3
seconds.
2. Turning the time control fully clock wise will set the on duration to 7 minutes +/- 2 minutes.
After testing and control adjustment, replace the faceplates by clic ing into position.
Issue no: 704773
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
info@greenbrook.co.uk
www.greenbrook.co.uk
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
GUARANTEE
Your GreenBroo Wall Switch Motion
detector OD100 is guaranteed for 1 year
from the date of purchase.
This is in addition to your statutory rights.
OD100 Ins.qxp_GU10 31/05/2019 15:54 Page 2