Thank you for purchasing your new greenhouse. We recommend you familiarise yourself with the instructions and read all safety information
before you commence assembly.
These instructions are divided into sections; B-base, partlists,1-sides, 2-front gable, 3-rear, 4-joining the four sides together, 5-roof, 6-vent, 7-door,
8-glazing(8a toughened glass, 8b horticultural glass, 8c polycarbonate glazing when available), 9-vent attachment, 10-door attachment, 11 anchoring
down, back cover-packing list. If you need to contact us for assistance please refer to the relevant section/s.
Safety Warning
Glass and aluminium can potentially cause injury. Please ensure you wear protective goggles, gloves, headgear and suitable footwear when
assembling and glazing the building.
Please remember that glass is fragile and should be handled with extreme care. Always clear up and dispose of any breakages immediately.
Do not assemble the greenhouse in high winds.
For safety reasons and ease of assembly, we recommend that this greenhouse is assembled by a minimum of two people.
Please clear all lying snow from the greenhouse roof as it can cause the roof to buckle or collapse.
Site Preparation
When selecting a site for your greenhouse, it is vital that you choose as flat and level an area as possible.
A concrete or slabbed base will provide the most solid foundation for your greenhouse.
IMPORTANT: Do not fix your building down until the building is fully assembled, including glazing.
Avoid placing your greenhouse under trees or in other vulnerable locations.
To minimise the risk of wind damage, try to select as sheltered a site as possible, e.g. beside a hedgerow or garden fence.
Additional Considerations
When you add the glazing foam to the structure (section 8) ensure that the white paper does not get wet to make its removal easier. The foam
only goes laterally, never horizontal where the glass is located.
Please bear in mind that assembling your greenhouse can be time consuming. You may need to spread the construction over two or more
days. We recommend that you avoid leaving the building partially glazed. If you ever have to leave your greenhouse half assembled and not
anchored down, weigh it down with slabs or bags of sand to stop the wind moving it.
You will find it helpful to prepare a large, clean and clear area in which to work in. A garage floor or flat lawn area is ideal.
If you have arranged for someone to install your greenhouse for you, please check that all components are included. Most parts are numbered
and can be identified by a stamp or removable label. Alternatively, the components can be identified by lengths detailed in the packing list (see
diagram below).
Anchoring down your greenhouse should be the final stage of construction (including glazing).
Once installed your greenhouse requires little maintenance, but to maintain the smooth running of
your door(s) WD40 or similar can be applied to the door wheels and lower door guides.
Guarantee
Your new greenhouse is guaranteed for 10 years against faulty manufacture of the framework. This
does not include glazing, moving parts, accidental damage or wind damage.
610mm
121
KEY
SYMBOL KEY DESCRIPTION
LOOK
THINK / CHOOSE?
THIS SECTION
RELATES TO ANOTHER
(e.g. 1 to 5 or 9 back to 6)
CORRECT
DO NOT FIX DOWN!
CUT
TIGHTEN
DO NOT WET!
CAN BE MIRRORED

3
A (mm) B (mm)
8’3” x 4’3” 1295
8’3” x 6’3” 1910
8’3” x 8’3” 2530
8’3” x 10’4” 3150
8’3” x 12’4” 3770
2530
OPTION 1: base on grass
OPTION 2: base on slabs
OPTION 3: base on concrete
OPTION 4: no base on brick
160
SY004 3720 2
SY009 3100 2
SY015 2480 2 2 4 2 2
SY029 1860 2
SY097 1240 2
SY160
280
4
Part
No. Section Size
(mm) 8x
4 8x
6 8x
8 8x
10 8x
12

4
Part
No. Section Size
(mm) 8
4 8
6 8
8 8
10 8
12
Page
Ref 8
LE Part
No. Section Size
(mm) 8
4 8
6 8
8 8
10 8
12
Page
Ref
1 3720 2
5 3100 2
17 2480 2
25 1860 2
55 1240 2
3 3720 2
8 3100 2
14 2480 2
27 1860 2
58 1240 2
49
1314
2
32
1210
2
4
6
8
10
4
11
2476
1
201
2
200
4
16
2476
1
36
1857
2
38 2
70
1538
2
71 2
72
1479
2
73 2
30
1210
2
31 2
136
924
2
19
2456
1
51
1480
4
2 3720 1
6 3100 1
12 2480 1
26 1860 1
57 1240 1
50
1484
2
4
6
8
10
68
1561
2
4
85 /
93
628 /
636
1
1
2
2
2
1069
608
-
-
1
2
3
121
619
1
2
123
612
1
2
124
610
2
4
SY
STAY
1
2
SY
PIN
2
4
SY-
BOLM4X10
SYNUTM4
M4
6
12
SY-
BOLM6
X22 22mm
2
4

5
Part
No. Section Size
(mm) 8
4 8
6 8
8 8
10 8
12
Page
Ref 8
LE
1017
619
1
1018
619
1
1067
619
1
1019
619
1
1047
1770
2
1042
wheel 2
1043 11 2
583 19 8
1041 100
2
571
fluff
3600
1
384
1
SY-
CLIP
220
260
320
360
400
SY-
FOAM
5000
15
15
18
18
21
SYZ
CLIP
n / a
85
100
115
130
150
Part
No. Section Size
(mm) 8
4 8
6 8
8 8
10 8
12
Page
Ref
10mm
1009
1260
1
128
330
1
300
n/a
1
1048
643
1
SY-
BOL
M6X11
M6
95
105
120
130
140
SY-
NUT
M6
M6
95
105
120
130
140
SY-
CROP
M6
1
-
-
-
-

6
Part No mm Quantity
58 1245 2
32 1210 2
55 1245 2
49 1314 2
M6 6
M6 6
4’
Part No mm Quantity
8 3100 2
32 1210 8
5 3100 2
49 1314 4
M6 20
M6 20
Part No mm Quantity
14 2480 2
32 1210 6
17 2480 2
49 1314 4
M6 16
M6 16
Part No mm Quantity
27 1860 2
32 1210 4
25 1860 2
49 1314 4
M6 12
M6 12
Part No mm Quantity
3 3720 2
32 1210 10
1 3720 2
49 1314 4
M6 24
M6 24
6’
8’
10’
12’
58
55
27
25
14
17
8
5
3
1
X 2
X 2
X 2
X 2
X 2
ALL VIEWS
INTERNAL

7
49
32
32

8
Part No mm Quantity
30 1210 1
31 1210 1
36 1857 1
38 1857 1
51 1480 2
16 2476 1
Part No mm Quantity
70 1538 1
71 1538 1
72 1479 1
73 1479 1
136 924 2
36 36
M6
2
1
16
36 38
51
30 31
136
72 73
136
51
+
70 71
136
51
INTERNAL VIEW
ALL VIEWS
INTERNAL

9
16
51
36 /
38
72 73
16 30 /
31
72 /
73
51
136
30 /
31
36 /
38
1048
ALL VIEWS
INTERNAL

10
Part No mm Quantity
19 2456 1
30 1210 1
31 1210 1
36 1857 1
38 1857 1
11 2476 1
Part No mm Quantity
51 1480 2
70 1538 1
71 1538 1
72 1479 1
73 1479 1
34 34
M6
2
1
19 51
11
36 38
51
30 31
19
72 73
51
70 71
ALL VIEWS
INTERNAL
INTERNAL VIEW

11
36 /
38
72 /
73
11 30 /
31
11
51
36 /
38
72 73
72 /
73
30 /
31
51
19
ALL VIEWS
INTERNAL

12

13
18mm
7mm
If you have a metal base and you live in a windy
location then you should drill and fix the frame to
the base using 10mm nuts and bolts. Drill centrally
between two vertical glazing bars for neatness (it is
not essential to drill every section). Make sure the
bolt head does NOT interfere with the line of the
glass. Cills should be drilled 18mm from the inside
vertical face to avoid the front glass face. Do NOT
anchor the structure to the ground until the end!
Packed with base!
M6 CROP
159

14
8’ Part No mm Quantity
12 2480 1
50 1484 6
68 1561 4
93 636 2
1069 608 1
22
6’ Part No mm Quantity
26 1860 1
50 1484 4
68 1561 4
93 636 1
14
4’ Part No mm Quantity
57 1240 1
50 1484 2
68 1561 2
85 628 1
1 2
1
2
3
4
4 50
3
7 / 1
68
68 50
50
68
49

15
12’ Part No mm Quantity
2 3720 1
50 1484 10
68 1561 4
93 636 2
1069 608 3
34
10’ Part No mm Quantity
6 3100 1
50 1484 8
68 1561 4
93 636 2
1069 608 2
28
X 2
M4 X 4
1069
1069
85 /
93?

16
124
121
121
124
610 x 610
M6 10mm X 2
X 2
X 4
M4 X 2
M4 X 2
X 4 or
OPTIONAL
CAPPING
X 1
1220mm
Part No mm Quantity
121 619 1
123 612 1
124 610 2

17
123
610 x 610

18
Part No mm Quantity
1017 619 1
1018 619 1
1019 619 1
1047 1770 2
1067 619 1
3.6 m
1017
1047
1067
1019
FLUFF
1047
X 2
X 2
X 8
X 2
INTERNAL VIEW
1018 X 1
X 2 X 2
4 m
FLUFF
FLUFF
ALL VIEWS
INTERNAL

19
1047
1047
1047
1017
FLUFF
1019
Glazing tips for sections 7 & 8:
The foam (see left) goes longitudinally in three
sections on each door stile and all over the
greenhouse frame, see overleaf, including the
roof corner bars. It never goes horizontally, the
glass just sits directly onto the aluminium cills in
the sides.
Remove the white paper on the foam before it
gets wet as it is difficult to remove, i.e. it
comes off in small pieces.
Clips (see overleaf) go roughly 1 every
305mm (1’) e.g. 610 x 610 pane you
would have 2 per side.

20
The adhesive foam
(SYFOAM) goes longitu-
dinally over the green-
house frame, see exam-
ples to the right. It never
goes horizontally, the
glass just sits directly
onto the aluminium cills in
the sides.
Remove the white paper
on the foam before it gets
wet as it is difficult to re-
move, i.e. it comes off in
small pieces.
This manual suits for next models
4
Table of contents
Other Greenhouse Greenhouse Kit manuals
Popular Greenhouse Kit manuals by other brands

Vitavia
Vitavia HERA 9000 Assembly instructions

ClearSpan
ClearSpan Premium Moo-Tel Series Assembly manual

PLANTA
PLANTA SIGMA 2021 EURO Assembling manual

Growing Spaces
Growing Spaces 42' GROWING DOME SNOWSHED DOORWAY installation guide

Dancover
Dancover GH117000 manual

Hanover
Hanover HANGHMN-2NAT Assembly instruction

GrowSpan
GrowSpan 500 Series manual

Madelux
Madelux PREMIUM installation manual

FLORABEST
FLORABEST 291609 Assembly instructions

Palram
Palram Bella 8'x8'- TwinWall Glazing Assembly instructions

ACF Greenhouses
ACF Greenhouses GROW MORE GM16 Assembly instructions

northern polytunnels
northern polytunnels Hobby instructions