Note:
1. Slide shower installations: Non return valve to be fitted to the shower wall
elbow outlet (not supplied).
2. Testing valve operation: Must have a rose / handset connected.
3. Twin shower installations: Top outlet to rose and bottom outlet to slide set.
INSTALLATION INSTRUCTIONS
SHOWER DIVERTER MIXER
Note: The Mixer can be mounted 48mm to 73mm behind finished wall surface.
Locate the correct position of the mixer by ensuring the “Hot” inlet, enters from the left.
The top outlet is for the shower the bottom outlet for the bath.
Ensure the diverter button is above the handle when the valve is fitted.
1. Position the mixer against a mounting board within the maximum and minimum
depth allowed and fix.
2. Connect water supply to the mixer and from the mixer to the outlets.
a. Hot inlet on the left and cold inlet on the right.
b. Top outlet is for the shower and the bottom outlet for the bath.
c. Do not pressure test with valve in the open position when the outlet is
closed.
d. Turn on water supply to the mixer and check for leaks.
3. Cut out an access hole in the wall lining for the mixer, as per drawing.
4. To secure the faceplate to the wall, remove the protective tape from the seal and
slide the faceplate over the mixer body and position against the wall lining.
a. Sealant will be required behind faceplate on uneven surfaces for water seal.
b. Ensure seals is in place on the inside of plate for valve body and diverter.
5. Install the handle onto the cartridge lever and tighten the screw under the handle
and fit button.