8 OM-BPM-G
The following information pertains to the CE model BPM-G, and replaces or augments
the information provided in OM-BPM. These appliances must be installed by a
competent person in conformity with the installation and servicing instructions and
national regulations in force at the time. Particular attention must be paid to the
following:
I. E. E. Regulations for Electrical Installations
Electricity at Work Regulations
Gas Safety (Installation & Use Regulations
Health and Safety at Work Act
Fire Precautions Act
Local and National Building Regulations
Detailed recommendations are contained in institute of gas engineers published
documents: IGE/UP/1, IGE/UP/2, BS6173 AND BS5440.
1. Installing Clearances
A. Vertical clearance of at least 1000 mm should be allowed between the top
edge of the flue outlet and any overlying surface.
B. Adequate ventilation, whether natural or mechanically induced, must be
provided to ensure a supply of fresh air for gas combustion, and to facilitate
effective removal of the products of combustion.
C. Ventilation recommendations for catering appliances are provided in BS
5440:2. Furthermore, guidance on the column of ventilation air required for
different types of catering equipment to ensure sufficient room ventilation
is provided at right.
D. For multiple installations, the requirements for individual appliances should
be added together. Installation should be made in accordance with local
and national regulations applying at the time. A competent installer must
be employed.
E. The appliance flue discharges horizontally from the rear of the unit. It
must not be directly connected to any flue, mechanical extraction system,
ducting, etc., which leads to the outside of the building. The appliance
is best discharged under an open canopy connected with a ventilating
system.
WARNING
INSTALLATION OF THE BRAISING PAN
MUST BE DONE BY PERSONNEL QUALIFIED
TO WORK WITH GAS AND ELECTRICITY.
IMPROPER INSTALLATION CAN RESULT IN
INJURY TO PERSONNEL AND/OR DAMAGE
TO EQUIPMENT.
Installation
CAUTION
INSTALLER MUST VERIFY THAT THE
INSTALLATION COMPLIES WITH THE
APPLICABLE LOCAL CODES AND
REGULATIONS.
WARNING
THIS UNIT IS FOR COMMERCIAL USE.
NEVER USE HOME OR RESIDENTIAL GRADE
GAS CONNECTIONS. THEY DO NOT MEET
GAS CODES AND COULD BE HAZARDOUS.
WARNING
ELECTRICALLY GROUND THE UNIT AT
THE TERMINAL PROVIDED. FAILURE
TO GROUND UNIT COULD RESULT IN
ELECTROCUTION AND DEATH.
Minimum
Clearance Recommended Clearance
Left Side 0mm 51mm (2”) for service, 153mm (6”) when faucet is
installed on left side
Right Side 0mm 305-405mm (12-16”), 153mm (6”) when faucet is
installed on right side
Rear 77mm 305mm (12”) for service
Electronic spark ignition