2.3
Safety instruction
The MIN TL-XH Inverters is designed and tested according to international safety
requirements(IEC62109-1,CE,VDE-AR-N4105,CEI0-21,VDE0126-1-1, AS4777,ect.)
;
however, certain safety precautions must be observed when installing and operating
this inverter. Read and follow all instructions, cautions and warnings in this installation
manual. If questions arise, please contact Growatt's technical services at +86 (0)755 2747
1942.
2.4
Assembly Warnings
Prior to installation, inspect the unit to ensure absence of any
transport or handling damage, which could affect insulation
integrity or safety clearances; failure todosocould result insafety
hazards.
Assemble the inverter perthe instructions inthis manual. Use care
when choosing installation location and adhere to specified
cooling requirements.
Unauthorized removal of necessary protections, improper use,
incorrect installation and operation may lead toserious safety and
shock hazards and/or equipmentdamage.
In order to minimize the potential of a shock hazard due to
hazardous voltages, cover the entire solar array with dark material
prior to connecting the array to any equipment.
Grounding the PV modules:The MIN TL-XH is a transformerless
inverter. That is why it has no galvanic separation. Do not ground
the DC circuits of the PV modules connected to the MIN TL-XH.
Only ground the mounting frame of the PV modules.If you
connect grounded PV modules to the MIN TL-XH, the error
m
e
ss
a
g
e
"
P
V
I
S
O
L
o
w
"
.
Comply with the local requirements for grounding the PV
modules and the PV generator. GROWATT recommends
connecting the generator frame and other electrically conductive
surfaces in a manner which ensures continuous conduction with
ground in order to have optimal protection of the system and
personnel.
2.5
Electrical Connection Warnings
Persons with limited physical or mental abilities may only work
with the Growatt inverter following proper instruction and under
constant supervision. Children are forbidden to play with the
Growatt inverter. Must keep the Growatt inverter away from
children.
Make all electrical connections (e.g. conductor termination,
fuses, PE connection, etc.) in accordance with prevailing
regulations. When working with the inverter powered on, adhere
toall prevailing safety regulations tominimize risk of accidents.
Systems with inverters typically require additional control (e.g.,
switches, disconnects) or protective devices (e.g., fusing circuit
breakers) depending upon the prevailing safety rules.
2.6
Operation Warnings
The components inthe inverter are live. Touching live components
can result in serious injury or death.
Do not open the inverter except the wire box by qualified persons.
Electricalinstallation,repairsandconversionsmayonlybecarried
out by electrically qualifiedpersons.
Do not touch damaged inverters.
Danger to life due to high voltages in the inverter
There isresidual voltage inthe inverter. The inverter takes 20
minutes to discharge.
Ensure all connectors aresealed and secure during operation.
Although designed to meet all safety requirements, some parts
and surfaces of Inverter are still hot during operation. To reduce
the risk of injury, do not touch the heat sink at the back of the
Inverter or nearby surfaces while Inverter is operating.
Incorrect sizing of the PV plant may result in voltages being
present which could destroy the inverter. The inverter display will
Turn the rotary switch of the DC Disconnect to the Off position
immediately.
All operations regarding transport, installation and start-up,
including maintenance must beoperated byqualified, trained
personnel and in compliance with all prevailing codes and
regulations.
Anytime the inverter has been disconnected from the power
network, use extremecaution assome components can retain
charge sufficient to create a shock hazard; to minimize
occurrence of such conditions, comply with all corresponding
safety symbols and markings present on the unit and in this
manual.
Inspecial cases, there may still be interference for the specified
applicationareadespitemaintainingstandardizedemissionlimit
values (e.g. when sensitive equipment is located at the setup
location or when the setup location is near radio or television
receivers).In this case, the operator is obliged to take proper
action to rectify thesituation.
Do not stay closer than 20 cm to the inverter for any length of
time.