1 2 3 456
MOD 3-15KTL3-X Quick Guide
425.2
171.8 87.4
391.5
213
141
2.3 Communication module installation
Inverter side
Inverter side Inverter side
Inverter side
▲Up
UninstallInstall
3.
Electrical connection
Please prepare the cable before connecting as follows.
1
2
3
4
Cable name
PV input wire
Type
Two or three polychromatic
multi-core copper wires
PV wire(such as PV1-F)
RS485
Recommend model
6mm²
6mm²
4mm² - 6mm²
/
No.
AC output wire
grounding wire
Protective Single multi-core
yellow-green wire 1.Please make sure all switches are in “OFF”
position before wiring. For personal safety,
please do not operate with electricity.
2.If the diameter of the cable does not match
the terminal, or the cable is aluminum wire,
please contact our after-sales personnel.
Note:
3.1 Grounding 3.2 AC output connection
3.3 DC connection
3.3.1 PV input terminal installation
System overview 2.1 Installation requirements
2.2 Wall mounting
Note:
1.When drilling holes in the wall, avoid water and electricity pipes, otherwise it may cause danger.
1.
2.
(1)Front panel (2)Touch button (3)LCD screen (4)LED indicator (5)Mounting bracket
(6)Heat sink (7)DC switch (8)PV terminal (9)RS485 port (10)USB port
(11)Vent valve (12)AC terminal (13)Waterproof
1.This document is for quick installation guidance only, please refer to User Manual for more details.
2.Growatt shall not be liable for any damage resulting from unproper installation.
Note:
Note:
Overview
Installation
≥300mm
≥300mm
≥300mm
≥300mm
≥300mm
186.4
178.4
Dual MPPTs for MOD 3-11KTL3-X,one string input per MPPT.Dual MPPTs for MOD 12-15KTL3-X ,one MPPT has one string,and other
one has two strings.
Communication
wire
8-10mm
123
45
4mm² - 6mm²
4mm² - 6mm²
Positive metal terminal
Positive metal terminal
Negative metal terminal
Negative metal terminal
Negative metal terminal
Please make sure the cable can not be
pulled out after pressing.
Pull the PV cable make sure there
is no loose or shaking.
Make sure the cable polarity is
correct and voltage is less than
1100V.
7811 12 13
10
9
10-12mm
12
34
10-12mm
Noted:Waterproof
must be blocked
with fireproof mud
to prevent water.
GR-UM-213-A-02
PV+
PV-
12
Customer can read more information by push button.
Mark
Describe
Explain
Touch mark
Single touch
Switch the display interface or the
current number plus 1
Double touch
Enter the setting state or confirm
Triple touch
Return to the previous display
interface
Long press for 5s
The current data returns to the
default value
Inverter status indicator
Red
Fault
Green
Normal operation
Red light flashing
Warning
It can display the basic information of inverter through LCD display
screen (PV/AC voltage,PV power,AC current,total power,generating
capacity, etc.).
7. Status of PV grid inverter
9.
Service and contact
Note:
1.Before installing the PV terminal, please
double-check that the PV input voltage and
current do not exceed the MPPT limits.
2.When installing the PV terminal, pay
attention to the difference between the
positive and negative poles and the one-to-
one correspondence between the terminals
and the machine.
3.There is a "click" sound when the terminal
is connected,please gently pulling the PV
wire to make sure there is no loose or
pulling off.
3.3.3 Communication cable installation
Click
Download
Manual Growatt New Energy
3.3.2 Plug in PV terminal
Note:
6.
Power on and off steps
8.
Export limitation setting
Exporlimit
OFF ON
Password
123
Set parameter
General
Advanced
Meter
CT
ExportLimit Rate
XXX.X%
Set OK
If the local grid company requires to limit the
output power from your inverter systems,we
introduce the concept of Export Limit Rate.The
ratio of your system output power divided by
the rated power of the inverter is called Export
Limited Rate.For example,if the local grid
companyonly accepts 4kW from your 5kW
system,then the Export Limit Rate of 5kW
inverter should be 80%.
5.
Post-installation check
No.
Acceptance criteria
No.
Acceptance criteria
1
The inverter is installed correctly, firmly and reliably.
6
The RS485 communication cable is installed correctly and firmly.
2
The ground wire connected well and the connection is firm
and reliable.
7
The cable tie port is trimmed well without leaving sharp
corners,meets the requirements of the user.
3
All switches are in the OFF state.
8
All exposed terminals are well protected and there are no vacant
ports.
4
All wiring is correct and securely connected.
9
Pay attention to clean up all construction residues.
5
The wiring of the cable is reasonable, meets the
requirements, and there is no phenomenon of broken skin.
Connecting Meter
4.
The following table describes how we can connect EASTRON meter (TPM-E)to inverter:
Meter Pin NO. Description Meter Connection
1/2/3/4
5/6/7/8
A
B
L1/L2/L3/N-in
L1/L2/L3/
N-out
RS485A
RS485B
Grid L1/L2/L3/N
AC connector & Load L1/L2/L3/N
SYS COM Pin 3 RS485A2
SYS COM Pin 4 RS485B2
L1
L2
L3
N
L1
L2
L3
N
1
2
3
4
L1
L2
L3
N
5
6
7
8
B A
No.
Description
Remarks
1
RS485A1
RS485
communication
signal
2
RS485B1
3
RS485A3
Anti-backflow meter
RS485 signal
4
RS485B3
12
34
Click!
Inverter side
Before turning the inverter on, please make sure the PV input voltage and current are within the MPPT limits.
Follow the steps below to turn the inverter on:
1.Switch on the build-in DC isolator at the bottom of the inverter.
2.Switch on the PV Array and DC isolator next to your inverter, if you can not find this switch, skip this step.
3.Switch on the Solar AC isolator if the inverter is more than 3 meters away from your switchboard.
4.Switch on the solar supply main switch in the switch board.
To shut down your system, follow this guide in reverse order.
Shenzhen Growatt New Energy Co., Ltd
4-13/F,Building A,Sino-German(Europe) Industrial Park,
Hangcheng Ave,Bao’an District, Shenzhen, China
+86 0755 2747 1942
www.ginverter.com
T
E
W
service@ginverter.com

Other manuals for MOD 3-15KTL3-X

1

Other Growatt Inverter manuals

Growatt Grid User manual

Growatt

Growatt Grid User manual

Growatt WIT 50-100K-AU User manual

Growatt

Growatt WIT 50-100K-AU User manual

Growatt MID 10KTL3-X User manual

Growatt

Growatt MID 10KTL3-X User manual

Growatt 2000HF User manual

Growatt

Growatt 2000HF User manual

Growatt 4000UE User manual

Growatt

Growatt 4000UE User manual

Growatt SPF 3500TL HVM-WPV User manual

Growatt

Growatt SPF 3500TL HVM-WPV User manual

Growatt UE Series User manual

Growatt

Growatt UE Series User manual

Growatt SPF 2000TL User manual

Growatt

Growatt SPF 2000TL User manual

Growatt 1500-US User manual

Growatt

Growatt 1500-US User manual

Growatt 7000MTL-S User manual

Growatt

Growatt 7000MTL-S User manual

Growatt 30000 TL3 User manual

Growatt

Growatt 30000 TL3 User manual

Growatt MIN 3000TL-XH-US User manual

Growatt

Growatt MIN 3000TL-XH-US User manual

Growatt SPF 3500TL LVM-US User manual

Growatt

Growatt SPF 3500TL LVM-US User manual

Growatt MID TL3-XH Series User manual

Growatt

Growatt MID TL3-XH Series User manual

Growatt SPF 3500TL HVM-Pro User manual

Growatt

Growatt SPF 3500TL HVM-Pro User manual

Growatt MOD TL3-XH Series User manual

Growatt

Growatt MOD TL3-XH Series User manual

Growatt SPF 5000TL HVM User manual

Growatt

Growatt SPF 5000TL HVM User manual

Growatt SPF 3500 ES User manual

Growatt

Growatt SPF 3500 ES User manual

Growatt 750-S User manual

Growatt

Growatt 750-S User manual

Growatt MAX 175KTL3-X HV User manual

Growatt

Growatt MAX 175KTL3-X HV User manual

Growatt MIN 2500TL-X User manual

Growatt

Growatt MIN 2500TL-X User manual

Growatt 3-10KTL3-XH User manual

Growatt

Growatt 3-10KTL3-XH User manual

Growatt MIN 2500TL-XE User manual

Growatt

Growatt MIN 2500TL-XE User manual

Growatt MAC 60KTL3-X LV User manual

Growatt

Growatt MAC 60KTL3-X LV User manual

Popular Inverter manuals by other brands

INVT Goodrive 200 Operation manual

INVT

INVT Goodrive 200 Operation manual

Mitsubishi Electric FR-HEL-N280K instruction manual

Mitsubishi Electric

Mitsubishi Electric FR-HEL-N280K instruction manual

Mitsubishi Electric FR-F800 instruction manual

Mitsubishi Electric

Mitsubishi Electric FR-F800 instruction manual

Toshiba TOSVERT VF-AS3 instruction manual

Toshiba

Toshiba TOSVERT VF-AS3 instruction manual

Powtran PI8600 Series user manual

Powtran

Powtran PI8600 Series user manual

FRO­NIUS Symo GEN24 6.0.Plus operating instructions

FRO­NIUS

FRO­NIUS Symo GEN24 6.0.Plus operating instructions

Control Techniques FXM5 user guide

Control Techniques

Control Techniques FXM5 user guide

VTS Medical Systems VTS2000 Series user manual

VTS Medical Systems

VTS Medical Systems VTS2000 Series user manual

Wagan Smart AC user manual

Wagan

Wagan Smart AC user manual

Sofar 25KTLX-G3 user manual

Sofar

Sofar 25KTLX-G3 user manual

Mastervolt MASS SINE 12/500 user manual

Mastervolt

Mastervolt MASS SINE 12/500 user manual

Morningstar TS-MPPT-60-600V-48-DB-TR Installation, operation and maintenance manual

Morningstar

Morningstar TS-MPPT-60-600V-48-DB-TR Installation, operation and maintenance manual

Huawei SUN2000-45KTL-US-HV-D0 quick guide

Huawei

Huawei SUN2000-45KTL-US-HV-D0 quick guide

Tronic KH 3900 operating instructions

Tronic

Tronic KH 3900 operating instructions

PowerTech MB3697 user manual

PowerTech

PowerTech MB3697 user manual

MULTIQUIP MQP240 Specifications

MULTIQUIP

MULTIQUIP MQP240 Specifications

esotec 101729 operating manual

esotec

esotec 101729 operating manual

Profi-Partner 46383 manual

Profi-Partner

Profi-Partner 46383 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.