DANGER
Electric shock
Death or serious personal injury
‐Switch off the power supply before you
start any work on the product.
‐Make sure that the power supply
cannot be switched on accidentally.
‐We recommend that you unplug the
control box from the socket.
If the potential-free alarm contact is to be
used to forward the alarm signal to a main
controller, connect the signal cable to
terminal block X2, terminals 3 and 4.
If the filling function is to be used instead
of the emptying function, move the lead
from terminal X1-1 to terminal X1-2.
7. Startup
Trim the electrodes to the desired length in
advance, depending on the pump. Take
into account the technically feasible
switching levels of the pump.
After installation, plug the control box into a socket
and plug the pump plug into the control box socket.
Carry out test runs. To do so, press and hold the
switch on the control box. The level controller will not
operate when the switch is actuated. The pump runs
for as long as the button is held.
If you encounter faults during test operation, verify
that the power supply is correct, that the connected
units function properly, and that the liquid has
sufficient conductivity. See section Fault finding for
more details.
If the switch on the control box is not pressed, the
level controller operates automatically.
Change over from the emptying function (delivery
state) to the filling function is described in section
Electrical connection.
8. Operation
Once the level controller has been installed and
started up, no further action is required.
The level controller operates automatically and
switches the connected wastewater pumps on and off
based on the liquid level.
For a trial run or to briefly switch the pump on and off
during commissioning or service work, the pump can
be manually operated by pushing the switch on the
control box. See also section Startup.
9. Taking the product out of operation
CAUTION
Scalding or etching
Minor or moderate personal injury
‐Wear personal protective equipment.
CAUTION
Biological hazard
Minor or moderate personal injury
‐The product will be classified as
contaminated if it has been used for a
liquid which is injurious to health or
toxic.
‐Wear personal protective equipment.
1. Disconnect the control box from the power supply,
for instance by unplugging the control box from
the socket.
2. Unplug the pump from the pump control box, or
remove the cables from the terminals in the event
of direct connection to the pump.
3. Remove the electrode bracket from the pump.
4. Carefully wash the electrodes with clean water.
10. Service
10.1 Maintenance
DANGER
Electric shock
Death or serious personal injury
‐Switch off the power supply before you
start any work on the product.
‐Make sure that the power supply
cannot be switched on accidentally.
‐We recommend that you unplug the
control box from the socket.
DANGER
Electric shock
Death or serious personal injury
‐Do not dismantle the plug-in control
box.
CAUTION
Scalding or etching
Minor or moderate personal injury
‐Wear personal protective equipment.
9
English (GB)