Panel Cutout and Dimensions
71mm
29mm
Panel cutout
3
1
2
36mm
59 mm
10mm
MAX
Side Lock
CONTROLLER
GASKET
PANEL
Suggested Wiring GS-UV-C-2 / GS-UV-C-3
8(1)A 250V MAX
UV Lamp
DOOR
LIMIT SWITCH
USER INTERFACE
UP Key
Touch to decrease Timer count value by 1
Minute/Second.
Touch to increase Timer count value by 1
Minute/Second.
Down Key
Touch and hold for 1 sec to stop & reset the
timer at last saved value.
Touch to start or hold the timer.
Also to save the timer count, if it is changed
by using up/down key.
Start/Hold Key
Reset Key
GS-UV-C-2 / GS-UV-C-3
Operating Instructions
Features :
ŸRange: 0 to 99 Minutes/Seconds
ŸRelay Output for UV-C.
ŸTimer setting in Minutes or Seconds.
ŸTimer hold at Door open & Buzzer will turn ON at
timer over.
ŸTimer run automatically as per setting.
ŸTimer Hold/start manually.
Caution
Introduction
UV Germicidal Irradiation is a disinfection method that uses short-
wavelength ultraviolet (ultraviolet C or UV-C) light to kill or inactivate
microorganisms by destroying nucleic acids and disrupting their DNA,
leaving them unable to perform vital cellular functions.
Door open sensing is provided to switch off the UV-Light. Buzzer will be
ON when timer is over.
This controller has timer feature to control UV light automatically as per
time setting. User can Hold/Start the UV light manually by using the key
in a UV-cabinet as per timer setting.
Maintenance: Cleaning: Clean the surface of the controller with a soft
moist cloth. Do not use abrasive detergents, petrol, alcohol or solvents.
WIRING: The electrical wiring should be done as shown in the
diagram. The power supply circuit should be connected to a protection
switch. The terminals admit wires of upto 2.5sq mm.
Notice: The information in this document is subject to change in order
to improve reliability , design or function without prior notice and does
not represent a commitment on the part of the company. In no event will
the company be liable for direct, indirect, special, incidental or
consequential damage arising out of the use or inability to use the
product or documentation, even if advised of the possibility of such
damages. No part of this manual may be reproduced or transmitted in
any form or by any means without the prior written permission of the
company.
WARNING: Improper wiring may cause irreparable damage and
personal injury. Kindly ensure that wiring is done by qualified personnel
only.
To fix the unit, slide the fastener 1 through the guides 2 as per the
position shown in the figure. Move the fastener in the direction of the
arrow, pressing tab 3 it permits to move the fastener in the opposite
direction of the arrow.
Installation : Fixing and dimensions of panel models:
Controller :Controller should be installed in a place protected by
vibration, water and corrosive gasses and where ambient temperature
does not exceed the values specified in the technical data.
GS-UV-C-2 GS-UV-C-3
Technical Data
Power input : 230 Vac ±15%,50-60Hz Standard.
Data storage : Flash APROM memory.
Relay output : UV-C SPDT relay 8(1)A, 250V AC
Panel Cutout : 29 X 71mm
Housing : Black ABS Plastic, Auto-extinguish
Front Cover : Polycarbonate Plastic
Dimensions : Frontal : 78 X 36mm, Depth : 59mm
Mounting : Flush panel mounting with fasteners
Protection : IP65 Front (with gasket)
Connections : Screw terminal blocks. < 2.5sq mm terminal
only.
Display : 2 X 17mm 7 segment display
: 2 LED Icons for Indication
Storage Temp. : -25.0ºC to 60.0ºC (non-condensing)
Operating Temp. : 0ºC to 60ºC (non-condensing)
Timer Range : 0 to 99 Min/sec (as per setting)
Digital Input (Potential Free) : Door Limit Switch
Buzzer : Internal
Operating Humidity : 20% to 85% (non-condensing)
Resolution : +/- 1 Min/Sec (Configurable)
Working Logic & Functions
Blinking
for 3 sec
Door
Open
Timer is over & Relay output is OFF.
Door is open & Relay output is OFF.
Display & LED Indications
LED Status Description
Timer is started & Relay output is ON.
ON
OFF
Blinking
Timer is stopped & Relay output
is OFF.
Timer is on hold & Relay output is
OFF.
UV-Light
Time Delay
To change Timer Measurement unit
To change Timer reset mode at Door Open
To change the timer unit, touch “ ” key for 2 sec. Display
will show “ ” if unit is set to minutes & Display will show “ ”
if unit is set to seconds. Timer will be set and display will show
“0”. Factory set value is in seconds.
+
To change the timer reset mode, touch “ ” key for 10 sec.
Display will show “ ” if timer reset mode is set to Manual &
Display will show “ ” if timer reset mode is Auto at Door Close.
+
Ordering Information
Sr. No. Timer Model
No. Brief Description Buzzer
Door Input
Sensing - DI
1.
2.
GS-UV-C-2
GS-UV-C-3
Included
Included
Internal
Internal
36x78mm,
8(1)A/250vac,
Relay based Timer
in Horizontal
Display
Orientation. Red
Color.
36x78mm,
8(1)A/250vac,
Relay based Timer
in Vertical Display
Orientation. Red
Color.
Disclaimer: This manual & its contents remain the sole property of Selector India
and shall not be reproduced or distributed without authorization. Although great care
has been taken in the preparation of this document, the company or its vendors in no
event will be liable for direct, indirect, special, incidental or consequential damage
arising out of the use or inability to use the product or documentation, even if advised
of the possibility of such damages. No part of this manual may be reproduced or
transmitted in any form or by any means without the prior written permission of the
company. Selector India, reserves the right to make and changes or improvements
without prior notice.
Warranty: This product is warranted against defects in materials and workmanship
for a period of one year from the date of purchase. During the warranty period,
product determined by us to be defective in form or function will be repaired or, at our
option, replaced at no charge. This warranty does not apply if the product has been
damaged by accident, abuse, and misuse or as a result of service or modification
other than by the company. This warranty is in lieu of any other warranty expressed
or implied. In no event shall the company be held liable for incidental or
consequential damages, including lost revenue or lost business opportunity arising
from the purchase of this product.
00 / 12.08.2020
3. To start the timer again touch “ ” key.
4. Timer is running & if user has touched key, then timer will
stop. Timer will reset and display will show last saved value
that is 10.
1. Use key to set value from 0 to 99. When set to ‘0’
timer function is inactive.
2. Example: Timer count value is set to 10, touch the “ ”
and timer will start countdown & Relay will switch ON. After
every minute or second, as per unit setting, display count will
decrease by 1. Once timer is over, display will blink “ ” for
3sec & Relay will be OFF. Timer will reset & Display will show
last set value of timer that is “10”.
5. Timer can Start and Hold by “ ” key.
7. When door is closed, Relay will start auto if timer reset mode is
set to auto else user has to start manually by “ ” key.
8. Buzzer will turn ON when timer is over & display will flash “ ”
for 3 seconds.
6. Relay will switch OFF when Door is open.
/
iii. Timer is over.
v. Door is open.
iv. Timer Unit is changed.
i. Timer value is changed.
ii. Timer is reset by key.
Relay will be OFF when below conditions occurs:
Note:

This manual suits for next models

1

Popular Timer manuals by other brands

LEGRAND 49730 manual

LEGRAND

LEGRAND 49730 manual

DGT CUBE user manual

DGT

DGT CUBE user manual

Bosch 56611 instructions

Bosch

Bosch 56611 instructions

ANSMANN AES 1 manual

ANSMANN

ANSMANN AES 1 manual

Brady 150744 quick start guide

Brady

Brady 150744 quick start guide

Orbit Manufacturing Fluid 57912 manual

Orbit Manufacturing

Orbit Manufacturing Fluid 57912 manual

Omron H3CR-AS manual

Omron

Omron H3CR-AS manual

Intermatic EI230 supplementary guide

Intermatic

Intermatic EI230 supplementary guide

Optimum ECONOMY 7 user manual

Optimum

Optimum ECONOMY 7 user manual

Omron H5F - instruction manual

Omron

Omron H5F - instruction manual

Hitachi PSC-A1T Installation and operation manual

Hitachi

Hitachi PSC-A1T Installation and operation manual

REV Ritter 15GD-3A-1 Installation and operating instructions

REV Ritter

REV Ritter 15GD-3A-1 Installation and operating instructions

Woods 50007 instruction manual

Woods

Woods 50007 instruction manual

Theben Timeguard BoostMaster DS3HD Installation & operating instructions

Theben

Theben Timeguard BoostMaster DS3HD Installation & operating instructions

Smeg KIT TIMER manual

Smeg

Smeg KIT TIMER manual

Keating Of Chicago Electronic Timer Wiring instruction

Keating Of Chicago

Keating Of Chicago Electronic Timer Wiring instruction

INSTEON TimerLinc 2456S3T quick start guide

INSTEON

INSTEON TimerLinc 2456S3T quick start guide

CDN TM22 Operation instructions

CDN

CDN TM22 Operation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.