HTTP://WWW.HOMBI.RU
30307503 Issue1.01
Features
Alarming by pressing, reset by a special key
Plug-in structure
Designed to comply with EN 54-11
Description
DC-9204 Innovation Manual Call Point (MCP) is
non-addressable. It alarms by the current caused by
pressing the action plate. It can be simply connected
to compatible conventional fire alarm system from
various manufacturers. This MCP is suitable for public
places. When there is fire, pressing the action plate on
this MCP can send alarm signal to compatible
conventional fire alarm control panel.
Connection and Cabling
Terminals on the MCP base are shown as Fig. 1.
I+ I- O+O-
60mm
Fig. 1
I+, I-: Input signal, connecting with compatible control
panel or the previous MCP.
O+, O-: Output signal, connecting with the next MCP.
Recommended Wiring
0.5mm2or above fire cable, subject to local codes.
Installation
The conduit can be surface mounted or flush
mounted.
Surface mounting:
First install the back box onto the wall using 4 screws,
then install the base onto the back box. Connect
cables to corresponding terminals as described above.
Hook the juts of the MCP body to the base, and then
press the part below the action plate to combine them
completely. Fig. 2 shows surface mounting.
Flush mounting:
Install the base onto the back box. Then combine the
enclosure and base the same as surface mounting.
Fig. 3 shows flush mounting.
Base
MCP Body
Back Box
Fig. 2
Base
Back Box
MCP Body
Fig. 3
Application
Application of the MCP is shown in Fig. 4.
Output-
Output+
Compatible Fire Alarm
Control Panel
Alarm Zone O-O+I-I+
To the next device
MCP
Fig. 4
Usage of the key
Vertically insert the key into the key-hole, then push it
with force and turn it clockwise. Turn the key back and
pull it out when the action plate is rebounded.
The Intelligent Solution
DC-9204
Innovation Manual Call Point
0832-CPD-0789
548g/03
報
HTTP://GSTRU.RUE-MAIL: [email protected]
HTTP://WWW.HOMBI.RU
30307503 Issue1.01
Usage of the test tool
The test tool is used to keep continuity during
commissioning or maintenance when MCP is not
installed, so that cable test can be carried out easily
and make the circuit completed.
Specification
Operating Voltage 24VDC (12VDC ~28VDC)
Standby Current 0mA
Alarm Current ≤30mA(equivalent
resistance is 470Ω/1W)
Indicator Red. Illuminates after
alarming.
Type of Initiating
Part Reusable
Initiating Mode Pressing the action plate
manually
Resuming Mode Manually resumed by a
special key
Wiring two-wire
Class TypeA, indoor use
Ingress Protection
Rating IP43
Ambient
Temperature -10℃~+55℃
Relative Humidity ≤95%, non-condensing
Material of
Enclosure ABS
Dimensions
(L×W×H)
87.1mm×87.1mm×58mm
(with back box)
87.1mm×87.1mm×23mm
(without back box)
Mounting Hole
Distance 60mm
Weight About 160g (with back box)
About 107g (without back
box)
Limited Warranty
GST warrants that the product will be free of charge
for repairing or replacing from defects in design,
materials and workmanship during the warranty period.
This warranty doesn’t cover any product that is found
to have been improperly installed or used in any way
not in accordance with the instructions supplied with
the product. Anybody, including the agents,
distributors or employees, is not in the position to
amend the contents of this warranty. Please contact
your local distributor for products not covered by this
warranty.
GST China
Gulf Security Technology Co., Ltd.
No. 80, Changjiang East Road,
QETDZ, Qinhuangdao, Hebei,
P. R. China 066004
Tel: +86 (0) 335 8502528
Fax: +86 (0) 335 8508942
[email protected]
www.gst.com.cn
GST UK
Global System Technology PLC
Lion Court, Staunton Harold Hall,
Melbourne Road, Ashby de la Zouch,
Leicestershire, England LE65 1RT
Tel: +44 1283 225 478
Fax: +44 1283 220 690
[email protected]
www.gst.uk.com
GST Dubai
Global System Technology PLC
P.O. Box 17998 Unit ZA04
JEBELALI Free Zone,
Dubai, UAE
Tel: +971 (0) 4 8833050
Fax: +971 (0) 4 8833053
[email protected]
www.gst.uk.com
This document is subject to change without notice. Please contact GST for more information or questions.
HTTP://GSTRU.RUE-MAIL: [email protected]

Other GST Smoke Alarm manuals

GST C-9403 Operator's manual

GST

GST C-9403 Operator's manual

GST DC-9101 IS User manual

GST

GST DC-9101 IS User manual

GST DI-M9102 User manual

GST

GST DI-M9102 User manual

GST DC-9101 User manual

GST

GST DC-9101 User manual

GST DI-M9101 User manual

GST

GST DI-M9101 User manual

GST C-9202 User manual

GST

GST C-9202 User manual

GST DC-9102 User manual

GST

GST DC-9102 User manual

GST I-9102 User manual

GST

GST I-9102 User manual

GST DC-M9101 User manual

GST

GST DC-M9101 User manual

GST DC-9101E User manual

GST

GST DC-9101E User manual

GST I-9301 User manual

GST

GST I-9301 User manual

GST DC-9101 IS User manual

GST

GST DC-9101 IS User manual

GST DC-M9102 User manual

GST

GST DC-M9102 User manual

GST DI-9101E User manual

GST

GST DI-9101E User manual

GST I-9102 User manual

GST

GST I-9102 User manual

GST C-9101 User manual

GST

GST C-9101 User manual

GST I-9102 User manual

GST

GST I-9102 User manual

GST C-9102 User manual

GST

GST C-9102 User manual

GST S-9102R User manual

GST

GST S-9102R User manual

GST C-9101 User manual

GST

GST C-9101 User manual

GST D Series User guide

GST

GST D Series User guide

Popular Smoke Alarm manuals by other brands

Metrona RM 680110 User information

Metrona

Metrona RM 680110 User information

Emerald Planet EP-RF-R1 user manual

Emerald Planet

Emerald Planet EP-RF-R1 user manual

Fire Fighting Enterprises Fireray 50 user manual

Fire Fighting Enterprises

Fire Fighting Enterprises Fireray 50 user manual

DSC FSA-210 Series Installation and operating instructions

DSC

DSC FSA-210 Series Installation and operating instructions

Tunstall 68005/96 User & installation instructions

Tunstall

Tunstall 68005/96 User & installation instructions

Mircom MIX-2351APA Installation and maintenance manual

Mircom

Mircom MIX-2351APA Installation and maintenance manual

Ziton ZP2 Series installation manual

Ziton

Ziton ZP2 Series installation manual

Shelly Plus Smoke User and safety guidelines

Shelly

Shelly Plus Smoke User and safety guidelines

A-Collection 6302618 installation instructions

A-Collection

A-Collection 6302618 installation instructions

jablotron JA-85ST quick start guide

jablotron

jablotron JA-85ST quick start guide

Zooper ZT37 -250 REP-AL/P Installation and commissioning manual

Zooper

Zooper ZT37 -250 REP-AL/P Installation and commissioning manual

Aegislink S-RF500 user manual

Aegislink

Aegislink S-RF500 user manual

CALECTRO UNIGUARD UG-2-A2 manual

CALECTRO

CALECTRO UNIGUARD UG-2-A2 manual

EDS OD12R installation manual

EDS

EDS OD12R installation manual

Universal Security Instruments Sensing Plus AMI3051S instructions

Universal Security Instruments

Universal Security Instruments Sensing Plus AMI3051S instructions

Edwards Signaling & Security Systems 517TB Series installation instructions

Edwards Signaling & Security Systems

Edwards Signaling & Security Systems 517TB Series installation instructions

First Alert SA340 user manual

First Alert

First Alert SA340 user manual

Air Products & Controls SL-DA4R Series Installation and maintenance instructions

Air Products & Controls

Air Products & Controls SL-DA4R Series Installation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.