GT GT-600 User manual

Sliding Gate Operator
User's Manual
GT-600,GT-1000,GT-1500
AND
GT2000 (SINGLE PHASE)

www.globetechinnovations.com
1
1. Products introduction
Please read the instructions carefully before proceeding.
MCU is supplied to control the gate operator.
Keypad / single button interface.
Have Infrared safety sensor interface.
Soft start and soft stop function and the soft stop width are
adjustable, and the soft start function can be disabled.
Working time is adjustable.
Motor output torque is adjustable.
Manual key release designed for emergency purposes.
2. Important safety information
Carefully read and follow all safety precautions and warning before
attempting to install and use this automatic gate operator.
The gate operator should be installed by a qualified technician;
otherwise, serious personal injury or property damage may
occur.
When opening or closing the gate, do not attempt to walk or
drive through the gate.
If enable the auto-close function, must use the infrared sensor.
Children should not be allowed to play near or operate automatic
gates.
The automatic gate operator must be grounded.
Install the gate operator on the inside of the property; DO NOT
install it on the outside of the property where the public has
access to it.
Be careful when in close proximity to moving parts where hands
or fingers could be pinched.

www.globetechinnovations.com
2
Do not allow control devices to be placed so that a person can
access them by reaching through the gate.
In the event of power failure, an emergency release key allows
you to operate the gate manually.
The operator should be switched off before repairing it or
opening its cover.
Please erase and reprogram the transmitter code after installing
the operator.
Make sure the Power supply (AC220V) of the gate operator is
suitable for the power supply in your area.
3. Main technical parameters
Type
GT600
GT1500
Power supply
220V, 50Hz
220V, 50Hz
Motor speed
55rpm
42rpm
Rated output power of motor
200W
500W
Remote control operating
distance
30m
(Frequency:433.92mHz)
30m
(Frequency:433.92mHz)
Remote control mode
Single
button
Single button
Output shaft height
58.5mm
58.5mm
Max. gate weight
600Kg
1400Kg
Output torque
16N²m
32N²m
Limit switch
Spring limit
switch/magnetic
Magnetic
limit switch
Noise
≤58dB
≤60dB
Duty cycle
S2, 15
minutes
S2, 15
minutes

www.globetechinnovations.com
3
extra remote control
20
20
Environmental temperature
-20°C~+50°
C
-20°C~+50°
C
Gate Move speed
13m/min
12m/min
4. Mechanical Installation
The SD 1006 & SD 1014 will handle gate weighting up to 600/1400kg
and up to 8m/12m if the proper installation procedures have been
followed.
The SD 1006 & SD 1014 gate operator operates by forcing a drive
rack by a drive gear. The entire configuration is shown in the
diagram below. The gate operator must be installed on the inside of
the gate.
Sliding gate Wall
Switch
Gate operator
Input power
Rack
Fig.1
Gate preparation
Be sure the gate is properly installed and slides smoothly before
installing the SD 1006 & SD 1014 sliding gate operator. The gate
must be plumb, level, and move freely.

www.globetechinnovations.com
4
Conduit
In order to protect the cable, use PVC conduit for low voltage power
cable and control wires. Conduit must be preset into the concrete
when it is poured. Wires within the conduit shall be located or
protected so that no damage can result from contact with any rough
or sharp part.
Concrete pad
The base unit of the gate operator requires a concrete pad in order to
maintain proper stability. The concrete pad should be approximately
450mm x 300mm x 200mm deep in order to providing for adequate
weight and structure to insure proper stable installation.
Anchors (see Fig.2)
You can use anchor bolts, anchors, washers and nuts. These
anchors must be set into the concrete when it is poured or you can
use wedge anchors to fasten the operator.
Fig.2
Operator base (see Fig.3)
After the concrete has hardened, mount the gate operator base to the
concrete pad. Verify that the base is properly leveled.
Gate operator
Gear
Groundsill
Input power
Plain washer
Nut
Spring washer
Nut

www.globetechinnovations.com
5
Using bolts and washers mount the gate operator to the base and
insert the cover. Check the operator and make sure it is lined up with
the gate. GT600 GT1500
Fig.3
Installation of Rack
Fix the three nuts (in the same package with rack) on the rack
element.
Lay the first piece of rack on the gear and weld the first nut on the
gate.
Move the gate manually, checking if the rack is resting on the
gear, and weld the second and third nut.
Bring another rack element near to the previous one. Move the
gate manually and weld the three nuts as the first rack, thus
proceeding until the gate is fully covered.
When the rack has been installed, to ensure it meshes correctly
with the gear.
The space between rack and gear is about 0.5mm.

www.globetechinnovations.com
6
Fig.4
Magnetic limit switch
To ensure safety, it is recommended to install limit switches at
both ends of the gate to prevent the gate from sliding out of the
rails. The rails must be installed horizontally.
Install the limit block as shown in Fig.5 and Fig.6. The magnetic
of limit switch and blocks are used to control the position of the
gate.
Release the gear with the key and push the sliding gate manually
to pre-determine the position, fix the block to the rack and lock
the gear by push up the release bar. Moving the gate electrically,
adjust the block to the proper position until the position of the
opening and closing meet the requirement.
Fig.5 Magnet limit switch

www.globetechinnovations.com
7
Fig.6 Magnet limit switch
Manual operation
In case of power failure use key unlock the lock and pull down the
release bar about 90 degree to open or close gate manually, use the
release key as follow:
Fit the supplied key in the lock.
Turn the key and pull down the release bar about 90°to release
the gear. (Note: Do not exceed 90°, be careful not to use too
much force, otherwise the release bar will be damaged.)
Open and close the gate manually.
Note: If the gate bumps the mounting post and cannot be electric
opened, move the gate a few inches by hand, thus you can release
the gate with the key, open and close the gate manually.
Fig. 7
6. Wire Connecting
Make sure that the power is OFF before making any electrical
connections.

www.globetechinnovations.com
8
Remove the cover, perform the wiring (See Fig.8 and wiring notes for
control board) and replace the cover again.
ON
OFF
N L N
SPEED GND VCC
CAP
MOT2
MOT1
COM
MOT
MOT
812
11
10
9
7
6
5
4
12 3
PE
LAMP
13
PE L
SW1
T2
9
7
RL2
RL1
VR2
VR1
65 10
1312
2
OC2
OC1
F3
F2
F1
C20
C19
C22
J3
J6
J1
POWER
LEARN
VR4
VR3
S1
U3
U2
VDR1
Q3
J2
HALL
U1
J5 X1
J4
POWER
MOTOR
Caution light
Protect Earth
Capacitor
Extral button
switch
O/S/C switch
Pedestrian switch
Infared sensor
Loop detector
Limit
swtich
+12VDC
GND/COM
COM
COM
Learn button
Open limit
Close limit
Fig.8
Wiring notes of control board
a. Power Input (terminal J3): PE (Earth),L (Live),N (Neutral).
GT600 & GT1500: AC220V
GT600 & GT1500::AC110V

www.globetechinnovations.com
9
b. Caution light: connect caution light wire to L and N of
LAMP(terminal J4)
GT600 & GT1500:: AC220V
GT600 & GT1500:: AC110V
c. Output power supply: 12VDC(7 of J5), COM (9 of J5), I.R. (8 of
J5 is N.C Infrared)
If the infrared beam is interrupted during closing, the gate will reverse
and open immediately. The product is not factory equipped with an
infrared device; the infrared output signal must be N.C.
From four-terminal
to the receiver
COM
OUT
RX Receiver connecting
JUMP
NC OR NO
NC
NO
Form two-terminal to the emitter
12--24V AC/ DC
TX Emitter connecting
power supply
7
9
8
Control board
Terminal J5
Fig.9 infrared Schematic diagram
d. Three-button switch / single-button switch (keypad): The GT600
& GT1500: is equipped with interfaces for three-button switch
and single-button switch (keypad).
To install the keypad attach one lead of your keypad to ‘5’of
terminal J2 and the other to the ‘4(COM)’. The keypad will
function in single channel mode.
For three-button switch installation, use the terminals for
multi-channel mode. Connect open wire of external button switch

www.globetechinnovations.com
10
to ‘1 (OPEN)’of terminal J2, connect close wire of switch to ‘2
(CLOSE)’, connect stop wire of switch to ‘3(STOP)’, connect
common wire of switch to ‘4(COM)’.
Com
Stop
Close
Open
Three-button
switch
terminal J2 Keypad
4
5
Control board
terminal block
Control board
terminal block
Single-button
switch
or keypad
6
1
2
3
terminal J2
4
5
6
1
2
3
Fig.10A
e. Pedestrian switch
Connect pedestrian switch wire to 4 and 6 terminal of J2. press
the switch the door will open 1 meter when the door is closed.
terminal J2 Switch
4
5
Control board
terminal block
Pedestrian
switch
6
1
2
3
Fig.10B

www.globetechinnovations.com
11
Motor and capacitor (Terminal J2, J4): MOT COM (com), MOT1
(Positive direction), MOT2 (Opposite direction), PE (Protect Earth), C
and C (capacitor). If the door move direction is wrong, please
change the MOT1 and MOT2 of motor, and change the block of
limit (Magnetic limit switch).
Motor
Mot1
Mot2
Mot
COM
PE
W
UV
Control
board
Terminal J6
Capacitor
Control board
terminal block
terminal J4
Fig.11f. Loop detector interface Connect wire see the
Fig.11A
terminal J2
LOOP
10
11
Control board
terminal block
Loop
detector
12
7
8
9
detector
output

www.globetechinnovations.com
12
The car through the loop the door will close itself when the door opened.
The car arrived the loop the door will reverse when the door closing, and
the door will auto closed after the car through the loop.
If the car stops on the loop the door can’t close.
7. Tuning and operation
a. Adjust the Adjustable resistance (see Fig.8)
VR1: For motor working total time adjustment.
Clockwise rotation to increase, counter-clockwise rotation to r
educe. The total time can be set to 10 seconds as minimum and
90 seconds as maximum.
VR2: For brake force adjustment in limit position.
Clockwise rotation to increase, counter-clockwise rotation to r
educe. Rotate to minimum to cancel brake function in place.
VR3: For slow stop width adjustment.
Clockwise rotation to increase, counter-clockwise rotation to r
educe.
VR4: For motor output force adjustment to keep safe usage.
Clockwise rotation to increase, counter-clockwise rotation to r
educe.
Warning:
Motor force can not be set too large, just drive the door is ok.

www.globetechinnovations.com
13
Remote control
The remote control works in a single channel mode. It has four
buttons. See Fig.12 Remote transmitter. The function of button
1, button 2、button3 are the same and button 4 is pedestrian
mode. With each press of the remote control button (1, 2 and 3)
which has been programmed, the gate will close, stop, open or
stop cycle.
Remote Pedestrian button: After you learn the transmitter, you
press the remote button 4 the door will open 1 meter when the door
is closed.
You can program/learn button 1, button 2, and button 3
individually. If you learn button1, the button 1 and button 4 are
enable, if you learn button 2 too, the button 2 and button 4 are
enable, the button 1 is disable.
Button 1
Button 2
Button 3
Button 4
Fig.12 Remote transmitter
Adding extra remote controls (Learn): Remove the cover, press
and hold the learn button ‘S1’(Fig.8) more than 2 seconds, then
the ‘LED of LEARN’ (Fig.8) will be on, then press the remote
control button which you want to use, the ‘LED’will turn on about
2 seconds and then turn off again. The learning process is
finished.
Up to 25 remote controls may be used.
Erase remote controls: To erase all existing remote controls,
press and hold learn button ‘S1’, the LED of ‘LEARN’will turns

www.globetechinnovations.com
14
on, release the button until the LED turns off. This indicates
that all the remote controls have been erased completely, if you
change another manufactory code transmitter must erase first.
Verify open direction: If the gate does not move in the desired
direction, then you will need to reverse the motor operating
direction, open the black plastic cover, you can do this by
exchanging wires ‘MOT1’and ‘MOT2’, ‘Open limit(13 of J5)’and
‘Close limit(11 of J5)’.
8. Programming Process
Adjust the DIP switch(see Fig13B and table 1)
1 2 3 4 1 2 3 4
1 2 3 4 1 2 3 4
Fig. 13A Fig.13B

www.globetechinnovations.com
15
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
Fig. 13C Fig. 13D
Table 1: DIP switch adjust
DIP
DIP-switch
Function SET
1
ON
(see Fig.13A)
No soft start mode
OFF
(see Fig.13A)
Soft start mode(need to power on
reset).
2
ON
(see Fig.13B)
N.C. limit switch(spring limit)
OFF
N.O. limit switch(magnetic limit)

www.globetechinnovations.com
16
3
ON
When the 3 and 4 all OFF, the
Auto-close function is disable. When
the 3 OFF and the 4 is ON, auto-close
time is near 12 Sec. when the 3 ON
and the 4 is OFF auto-close time is
near 24 sec. when the 3 and the 4 is
all in ON position, the auto-close time
is near 36 sec.
OFF
(see Fig.13C)
4
ON
OFF
(see Fig.13D)
5
ON
OFF
Meet obstacle reversal function
off-enable on- disable
NOTE:
(1) You must follow the operating instruction as above, any
wrong operation is not allowed during setting. If your device
responds to your requested function correctly, you have set
the function successfully, otherwise repeat the above setup
instruction until your device responds to your expected
function.
(2) If the gate can not be moved, please check whether the gate
is obstructed or the gate is too weight.
Activities Covered in this section
Remote transmitter: With each press of the button, the gate will
close, stop, open or stop cycle. (Single-button mode)
Three-button mode external button switch (not supply):
press ‘OPEN’button, the gate opens. Press ‘STOP’button, the
gate stops. Press ‘CLOSE’button, the gate closes.
Single-button mode external button switch / keypad (not
supply): With each press of the button, the gate will close, stop,
open or stop cycle.
Auto-close function: This feature can be selected to make the
gate stay open for some seconds before it automatically closes.
The auto-close time can be adjusted to between 12, 24 and 36

www.globetechinnovations.com
17
seconds.
Safe guard (Infrared photocell): If infrared beam is interrupted
during closing, the gate will reverse and go open immediately.
This feature will not function if the gate is in fully opened and
closed positions or during opening.
Open priority: The gate will return to open if press ‘OPEN’
button of external button switch during closing.
Limit switch: The switch is used to accurately stop the gate in
the opened and closed positions.
If the gate stops at opened position when the limit switch is
reached, the gate will not move if you press ‘OPEN’button.
If the gate stops at closed position when the limit switch is
reached, the gate will not move if you press ‘CLOSE’button.
The device is installed with a thermal protector, the thermal
protector will switch off the motor automatically in case of the
temperature is higher than 120°C and switch on the motor
automatically when the temperature is lower than 85°C±5 °C.
9. LED indicate
a. LED of Power indicated the input power.
b. LED of LEARN indicated the transmitter learn status.
c. LED 1 indicate the ‘CLOSE’external button, if the button is
pressed the LED will light.
d. LED 2 indicate the ‘OPEN’external button, if the button is
pressed the LED will light.
e. LED 3 indicate the ‘STOP’external button, if the button is
pressed the LED will light.
f. LED 5 indicate the ‘O/S/C’external button, if the button is
pressed the LED will light.
g. LED 6 indicate the ‘pedestrian switch’external button, if the
button is pressed the LED will light.

www.globetechinnovations.com
18
h. LED 7 indicate the ‘infrared sensor’status, if the output is
connected the LED will light.
i. LED 9 indicate the ‘Loop detector’status, if the output is
connected the LED will light.
j. LED 10 indicate the ‘Close limit switch’status, if the switch is
connected the LED will light.
k. LED 12 indicate the ‘Open limit switch’status, if the switch is
connected the LED will light.
All these LED position see the Fig.8
10. Maintenance
Check the door once a month. The door should be carefully
checked for balance. The door must be in good working order.
We suggest for safety reasons, photocells be used on all gates.
Disconnect from mains supply before replacing bulb.
Be sure to read the entire manual before attempting to perform
any installation or service to the door operator.
Our company reserves the right to change the design and
specification without prior notification.
11. Troubleshooting
Trouble
Possible causes
Solutions
The door fails to
open and close.
LED display
does not light.
1. Power is OFF
2. Fuse burn
1. Make sure that power is
ON.
2. Replace fuse.

www.globetechinnovations.com
19
The door can
open fails to
close.
1. Infrared beam is
obstructed.
2. Infrared sensor
function is enabling, but
the sensor has not been
installed.
1. Remove obstructions.
2. Make sure the infrared
sensor function is disabling.
Remote
transmitter does
not work.
1. Battery level may be
low
2. Transmitter code is
lost
1. Replace the battery
inside the transmitter.
2. Reprogram the
transmitter.
The transmitter
operating
distance is too
short.
Battery level may be
low.
Replace battery.
11. Packing list
After receiving the gate operator, you should make an
unpack-inspection, in which you should check whether the product
was damaged. If you have any problem please contact our dealer.
You should find the following items in our standard packing:
No.
Item
Quantity
1
(GT-600,1000,1500,2000)
sliding gate operator
1
2
Transmitter
2
3
Release key
2
4
User’s manual
1
This manual suits for next models
3
Table of contents