K3590-GP 3/03
FA6150KP-GP
REMOTE KEYPAD
INSTALLATION GUIDE
GENERAL INFORMATION
The FA6150KP-GP is an addressable, fixed-word display,
remote keypad designed for use with GUARDIAN
PROTECTION control panels. The address is set via the
keypad keys, and may be continuously backlit for
convenience (depending on the control panel being used).
KEYPAD DISPLAY AND LEDS
The keypad has the following display features:
x
Fixed-Word display of System Status
x
3-digit Zone Identifier
x
Backlit Display (optional on some controls)
x
Dedicated Special Function Keys
x
Built-in Piezo Sounder
The following table shows the LEDs and their functions:
LED Function
Red Lights when the system is “ARMED” in any
mode
Green Lights when the system is "READY" to be
armed.
The keypad’s Special Function Keys; A, B, C, and D, may be
programmed for panic alarms or other special functions
such as single-button arming or macros. See the control
panel’s Installation and Setup Guide for details.
Function keys must be held down for at least 2
seconds to activate an alarm; key pairs activate
immediately.
Special Function Keys/Panic Alarm Key Pairs
Aor [1] & [✱]
Bor [✱] & [#]
Cor [3] & [#]
D(Special Functions only)
Refer to the control panel's Installation and
Setup Guide for Special Function Key options.
WIRING AND INSTALLATION
The keypad can be surface mounted directly to a wall, or to
a single- or double-gang electrical box.
1. Remove the case back by pushing down two "snaps"
along the keypad's bottom edge and pulling the two
halves apart. See Figure 1 below.
2. Route wiring from the control panel through the
opening in the case back.
3. Mount the case back to a wall or electrical box.
4. Wire directly from the keypad’s terminal block to
the terminal block on the control board as follows:
Wiring Table
Keypad Control Panel Color
V
G Data Out
Data In Green

GND

Aux Pwr Black
+ +12VDC + Aux Pwr Red
W
Y Data In Data Out Yellow
See the control panel’s Installation Instructions for
more complete details.
5. Reattach the keypad to its case back.
ARMED
READY
6150-005-V0
MOUNTING RELEASE SNAPS
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
#
Figure 1. FA6150KP with Protective Door Removed
¬.*3!l
K3590-GP 3/03
SETTING THE KEYPAD ADDRESS
The keypad can either be set for an address of 00-30, or to
the non-addressable mode (31). The keypad's default
address is 31. (See the control panel’s instructions for
specific addresses for the control you are using.)
To change the keypad's address, do the following:
1. Enter address mode: Power up the keypad. Within 60
seconds of power-up, press and hold down the [1] and [3]
keys at the same time for 3 seconds. (If unable to enter
address mode, power up and try again.)
The current keypad address will be displayed, and the
cursor will be under the "tens" digit. If 10 seconds have
passed with no key entry, the keypad automatically exits
address mode. You must power down, power up and
start address mode again.
NOTE: The keypad will not enter address mode if the
panel to which it is connected is in programming mode.
2. Set the current address to "00": Press [0] to clear the
current "tens" digit. The cursor will move to the "ones"
digit position. Press [0] to clear the current "ones" digit.
The cursor will move back to the "tens" digit position.
3. Enter the keypad's address: Enter the proper "tens" digit
of the keypad's address. The cursor will move to the
"ones" digit position. Enter the proper "ones" digit of the
keypad's address. Note that address "31" sets the
keypad to non-addressable mode.
4. Exit address mode: Press [✱] to save the displayed
address and exit address mode.
VIEWING THE KEYPAD ADDRESS
Press and hold down the [1] and [3] keys at the same time
for about 3 seconds. The current address is displayed. No
key entry is allowed. Press any key to exit or wait 10
seconds to automatically exit viewing mode.
FUNCTION KEY LABELS
A set of adhesive-backed labels with some typical function
symbols (i.e., fire, police, personal emergency, etc.) is
provided. These labels can be placed on or next to the keys
to identify each key's function for the end user (as
determined by the control panel's capability and
programming; see the control's instructions).
SPECIFICATIONS
Physical: 4-7/8"H x 6-1/4"W x 1"D
Display: Fixed-Word LCD (backlit).
Sounder: Piezo-electric (fire alarm is loud, pulsing single
tone; burglary alarm is loud, continuous, dual-
tone).
Voltage: 12VDC
Current: 70mA (ARMED LED lit, LCD backlight and
sounder on), reduces to 40mA when panel is
operating in standby mode (backlight off).
`
REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED
FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM.

Popular Keypad manuals by other brands

Azeron Classic manual

Azeron

Azeron Classic manual

Aleko LM106 user manual

Aleko

Aleko LM106 user manual

Channel Vision A0125 instructions

Channel Vision

Channel Vision A0125 instructions

ADEMCO Galant 6128 RFH Installation instructions and operating guide

ADEMCO

ADEMCO Galant 6128 RFH Installation instructions and operating guide

Bosch D1260 Series user guide

Bosch

Bosch D1260 Series user guide

Bosch D1265 quick guide

Bosch

Bosch D1265 quick guide

LEGRAND AU7050 installation instructions

LEGRAND

LEGRAND AU7050 installation instructions

DSC PK5500 installation instructions

DSC

DSC PK5500 installation instructions

Paradox Hellas S.A. SmartX KSDA quick start guide

Paradox Hellas S.A.

Paradox Hellas S.A. SmartX KSDA quick start guide

Visonic KP-140 PG2 user guide

Visonic

Visonic KP-140 PG2 user guide

Northern KP-10 specification

Northern

Northern KP-10 specification

Seip Digi-Pad SKR4C433 manual

Seip

Seip Digi-Pad SKR4C433 manual

Linear 298601 installation instructions

Linear

Linear 298601 installation instructions

Tyco Visonic  KP-241 quick start guide

Tyco

Tyco Visonic KP-241 quick start guide

Comdial ExecuTech Single Line 1432 user guide

Comdial

Comdial ExecuTech Single Line 1432 user guide

FAAC XKPR manual

FAAC

FAAC XKPR manual

B&K CK1.2 owner's manual

B&K

B&K CK1.2 owner's manual

Competition DH16A-09DL instruction manual

Competition

Competition DH16A-09DL instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.