HFU-09,12,18HA03/R2(DB) Specifications
2
Domestic Air Conditioner
2. Specifications
NOMINALCAPACITY and NOMINAL INPUT
Model HFU-09HA03/R(DB) HFU-12HA03/R(DB) HFU-18HA03/R(DB)
Cooling(1) min.~norm.~max. w 750.~2600.~3200. 850.~3600.~4200. 1050.~5000.~5800.NORMINAL
CAPACITY(3-4) Heating(2) min.~norm.~max. w 800.~3200.~4000. 1000.~4000.~4500. 1200.~6000.~7000.
Cooling min.~norm.~max. w 300.~760.~1150. 320.~1100.~1450. 420.~1550.~2100.NORMINAL
INPUT Heating min.~norm.~max. w 350.~880.~1200. 380.~1100.~1600. 550.~1650.~2300.
EER Cooling 3.42 3.27 3.23
COP Heating 3.63 3.63 3.63
ANNUAL ENERGY
CONSUMPTION(9)
Cooling kwh 400 540 750
TECHNICAL SPECIFICATIONS
INDOOR UNITS HFU-09HA03/R(DB) HFU-12HA03/R(DB) HFU-18HA03/R(DB)
H mm 640 640 640
W mm 720 720 720
DIMENSIONS Unit
D mm 255 255 255
WEIGHT Unit KG 17 17.5 17.5
COLOR Unit WHITE WHITE WHITE
high dB(A) 42/41 44/43 48/47
medium dB(A) 39/38 41/40 45/43
Sound
pressure(cooling/heating)(5)
low dB(A) 37/35 38/36 42/40
SOUND
LEVEL
Sound
power(cooling/heating)(6)
high dB(A) 52/51 54/53 58/57
high m3 /min 7.5 8.5 11
medium m3 /min 6 7.5 9.5
Air flow
rate(cooling/h
eating) low m3 /min 4.8 6 8.5
steps 4steps,silent and auto 4steps,silent and auto 4steps,silent and auto
high rpm 900 1000 1200
medium rpm 850 975 1125
Speed(cooling
/heating)
low rpm 800 850 1050
Type Cross flow fan Cross flow fan Cross flow fan
FAN
Motor output(upper/lower)20/11 20/11 20/11
AIR FILTER
Removable/washable/
mildew proof
Removable/washable/
mildew proof
Removable/washable/
mildew proof
REMOTE CONTROLLER YR-H05 YR-H05 YR-H05
liquid mm 6.35 6.35 6.35
gas mm
9.52 9.52 12.7
PIPING
CONNECTIONS(external
diameter) drain mm 16 16 16
INSULATION MATERIAL
Heat insulation type
both liquid and gas
pipes
both liquid and gas
pipes
both liquid and gas
pipes