PAGE 497878C (Rev. C - 02/18)
HRFG - ER*B HRFG - SR*B HRFG - SER*B
INSTALLATION INSTRUCTIONS
1. Install remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from
between compressor and side panel. Slide chiller onto the shelf and position it to the left within the guides on
the shelf. NOTE: Building construction must allow for adequate air ow on both sides, top, and back of chiller.
A minimum of 4" (102mm) on both sides and top is required. See chiller instructions for additional instructions.
2. Make water supply connections. The inlet port is marked on the chiller (1/4" O.D. copper tube). Bend the
copper tube (provided) at an appropriate length from chiller to opening in frame. Install the in-line strainer
(provided with chiller) by pushing it in until it reachs a positive stop, approximately 3/4" (19mm) on the marked
chiller inlet port. Attach an unplated and deburred copper water inlet line and a service stop (not provided) to the
in-line strainer. Turn on the water supply and ush the line thoroughly. DO NOT SOLDER
TUBES WHILE INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
3. Hang the upper panel on the mounting frame hanger. Align holes in the panel with the holes in the mounting
frame. Be sure that panel is engaged with hanger at top of frame before releasing it.
4. Install fountain. Remove access cover plate on underside of fountains and save the screws. Mount the
fountains to the upper panel and the wall frame with (4) 5/16" x 1-1/4" (32mm) long bolts, washers, and nuts.
Tighten securely, but do not overtighten. Over tightening will crack the Marblyte Fountain.
NOTE: The short fountain should be mounted to the upper left hand side of the panel.
5. Remove elbow from end of p-trap and attach it to drain tube. Re-attach elbow to p-trap and cut waste tube to
required length using plumbing hardware and trap as a guide.
6. Make connection between remote chiller outlet tube and fountain(s). Outlet port is marked on the chiller (1/4"
O.D. copper tube). Install a 1/4" union/tee (provided) on the marked chiller outlet port. Insert the 1/4" poly tubing
coming from the fountain(s) into the union/tee. Turn on water supply and check for leaks.
DO NOT SOLDER TUBES WHILE INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY
RESULT. (See gure 5 or 6).
7. These products are designed to operate on 20-105 PSI supply line pressure. If inlet pressure is above 105 PSI,
a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting these
products to supply line pressures lower than 20 PSI or higher than 105 PSI is not covered by warranty.
8. Make electrical connections to the chiller. See chiller instructions.
9. Check stream height from bubbler. Stream height is factory set at 35-40 PSI. If supply pressure varies greatly
from this, adjust the screw on regulator item 2 by using a small screwdriver through the small hole in the push
button item 5 (See Fig.8). Clockwise adjustment will raise stream height and counter-clockwise adjustment will
lower stream height. For best adjustment stream height should be approximately 1-1/2" (38mm) above the bubbler
guard (See Figure 7, Page 5).
10. Mount lower panel. Loosen the (2) #10-24 x 5/8" (16mm) screws at frame bottom lip. Slide upper tongue of
lower panel under lower edge of already installed upper panel. Tighten previously loosened screws securely.
11. Replace bottom access panel to fountain basin using screws provided. Tighten securely.
Care and Maintenance of Halsey Taylor Marblyte Fountains
Marblyte provides an exremely durable, nonporous surface which resists staining. Care is very simple. Routine
cleaning with a soft sponge or cloth, or with water or non-abrasive aerosol foam cleaner, is all that is normally needed
to give many years of trouble free service. Cleaners left standing on the fountain surface can dull the surface nish.
Be certain to rinse all cleaning agents completely and polish with a soft cloth.
Harsh abrasive cleaners are not required and should not be used.
Mild abrasives such as liquid automotive cleaning compound or baking soda paste will remove simple scratches
and stains. Cigarette burns can normally be removed without noticeable effect. Deeper scratches or gouges can be
corrected with ne grit sandpaper (240 grit then 400 grit) or a green Scotchbrite pad.
To maintain or regain luster and make cleaning easier, periodic applications of automobile wax or like products will
keep the nish looking like new.
Orice Assy: Mineral deposits on orice can cause water ow to spurt or not regulate. Mineral deposits may be removed from the
orice with a small round le not over 1/8" diameter or small diameter wire. CAUTION: DO NOT le or cut orice material.
Stream Regulator: If orice is free of material deposits, regulate ow as instructions on page 4 (Step 9). If replacement is
necessary, see parts list for correct regulator part number.
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To
remove tubing from the tting, relieve water pressure, push in on the gray collar while pulling on the tubing(see Fig 2, Page 1). To
insert tubing, push tube straight into tting until it reaches a positive stop, approximately 3/4".
TROUBLE SHOOTING & MAINTENANCE