HANCOM LIFECARE SCA420 User manual

Self-Contained
Breathing Apparatus
SCA420
SCA680
SCA790
INSTRUCTION MANUAL
This SCBA(Self-Contained Breathing Apparatus) is certied by
the KFI(Korea Fire Institute)

www.sancheong.com
02 03
SCBA
1. Warnings and cautions 4
2. Generalspecications 6
3. Congurationandfeatures 8
4. Before-useinspections 12
Mounting cylinder on harness
Leakage test
Alarm
Facepiece
Regulator
Flashing locator lights
Air switch knob
5. Howtouseairrespirator 16
6. Cleaningandinspectionafteruse 21
7. Storage 24
8. Storingofcylinders 24
9. Cautionduringtheuseofcylinders 24
10.Warrantycoverageandcustomerservices 26
CONTENTS

www.sancheong.com
02 03
SCBA
Thank you for purchasing SanCheong’s positive pressure air respirator.
This instruction manual must be carefully read and followed by all persons who have or will
have the responsibility for using or servicing this SCBA.
This SCBA will perform as designed only if used and serviced according to the instructions;
Otherwise it could fail to perform as designed, and improper use of this SCBA may result in
serious personal injury or death.
1. Warnings and cautions 4
2. Generalspecications 6
3. Congurationandfeatures 8
4. Before-useinspections 12
Mounting cylinder on harness
Leakage test
Alarm
Facepiece
Regulator
Flashing locator lights
Air switch knob
5. Howtouseairrespirator 16
6. Cleaningandinspectionafteruse 21
7. Storage 24
8. Storingofcylinders 24
9. Cautionduringtheuseofcylinders 24
10.Warrantycoverageandcustomerservices 26
CONTENTS

www.sancheong.com
04 05
SCBA
Warnings and cautions
1
■ The warning and caution marks mean the following;
Warning
1. Forthesakeofsafety,readtheinstructioncarefullyandgetsufcienttrainingpriortouse
the air respirator.
2. Ifanaccidentoccursduetounauthorizedmodicationoralternation,SanCheongshall
not take any responsibilities.
3. NeverusetheAmbientairmodeinaplaceshortofoxygenbyitsconcentration18%or
less,orinaplacecontaminatedbytoxicgas.Usingthebreathingapparatusinsuchplace
may lead to serious injuries or death.
4. Never use the positive pressure air respirator underwater or as a scuba dive.
5. If,duringaleaktestorduringtheprocessofcleaning,anysoapwaterorothersolution
getsintotheinsidethepositivepressureregulatorand/oralarms,itmayincurequipment
malfunction.Takecautionasitmayleadtoseriousdanger.
6. Removingthefacepieceinadangerousplacecontaminatedbytoxicgasmayleadto
suffocationleadingtodeath.Alwaysmovetoasafeplacebeforeremovingthefacepiece.
7. Usingstrongdetergentsorcorrosiveagenttocleanthecylindermaycausedestruction
ofthecylinderduetothestress-corrosioncrackingphenomenon.Thismayleadto
serious injuries or death.
8. Usinganairrespiratorwithcrackedordamagedpositivepressureregulatormaycause
seriousinjuryordeath.Neverusesuchdefectiverespirator.Contactyourlocaldistributor
ormanufacturerforinspectionandrepair.
9. Usingthepositivepressureregulatorwatercontainedinitmayincureequipment
malfunction.Getridofmoistureorwaterinthepositivepressureregulatorbeforeuse.
10.Ifanytroubleoccursontheairrespirator,donotattempttorepairit.Contactyourlocal
distributorormanufacturerforinspectionandrepair.SanCheongshallnottakeany
responsibilityifanyaccidentoccursfromequipmentthathasnotbeenrepairedby
manufacturerorifpartsnotdesignatedbymanufacturerhavebeenused.
Caution
1. Theairrespiratorisdesignedforpersonswhoworkatthesiteofre,toxicgashandling
sites,orataplacewhereoxygenisshort.Neverusetheproductforotherthanthe
intended purposes.
2. Ifyoufeeldifcultyofbreathing,headacheordizziness,orsmellsomething,stopusing
immediatelyandchecktheconditionofyourhealthandthesafetyoftheairrespirator.
3. Thefacepieceismadeofsyntheticrubberandmaycausesideeffectstotheskinofthe
personallergictosuchmaterial.Ifyouareallergictosuchmaterials,donotwearthe
facepiece.
4. Theairrespiratorisheavyandlargercomparedwithotherordinarypersonalsafety
equipment.Ifyouusetheequipmentinanarrowplacewhereyouractivityislimited,you
maysuffercriticalinjuries.
5. Checkthehosefordamageorairleakfromconnectors.Ifanydefectsarediscovered,
contactyourlocaldistributorormanufacturerforinspectionandrepair.
6. Ifairleakisdiscoveredonthevalveorhoseconnectingparts,stopusingtheproduct
immediately,andcontactyourlocaldistributorormanufacturerforinspectionandrepair.
7. Seriousscratchesonthefaceshieldmayreducevisibilitywhichcreatingadanger.Replace
thefaceshieldimmediatelyifscratchedontheshield.
8. Inordertopreventobstructionofviewbybreathing,spreadanti-fogsolutiononinnerpart
ofthefaceshield.
9. Duetouser’sbodyfeaturessuchasbeard,hairandmustache,andtheglassesworn
bytheuser,thefacepiecemaynotperfectlyttheface.Ifthereisanygapbetween
thefacepieceandtheface,airmayleakoutrapidlyreducingthetimeofuse.
Takeextracautions.
10.Whenllingthehigh-pressurecylinder(hereinafterreferredtoas“cylinder”),checkand
replacetheaircompressorlterperiodicallytopreventforeignsubstancesfromgettinginto
the cylinder.
11. Always wear the air respirator in a clean air place.
12.If,duringtheprocessofusingtheairrespirator,thepositivepressureregulatorfails,
immediatelyopentheBy-passvalve(emergencyvalve)tocontinuebreathing.Escapeto
asafeplace,andcontactyourlocaldistributorormanufacturerforinspectionandrepair.
Warning
Caution
Serious body injuries or death may result when instructions are violated.
Materiallossorbodyinjuriesareexpectedwheninstructionsareviolated.
Caution
Warning

www.sancheong.com
04 05
SCBA
Warnings and cautions
1
■ The warning and caution marks mean the following;
Warning
1. Forthesakeofsafety,readtheinstructioncarefullyandgetsufcienttrainingpriortouse
the air respirator.
2. Ifanaccidentoccursduetounauthorizedmodicationoralternation,SanCheongshall
not take any responsibilities.
3. NeverusetheAmbientairmodeinaplaceshortofoxygenbyitsconcentration18%or
less,orinaplacecontaminatedbytoxicgas.Usingthebreathingapparatusinsuchplace
may lead to serious injuries or death.
4. Never use the positive pressure air respirator underwater or as a scuba dive.
5. If,duringaleaktestorduringtheprocessofcleaning,anysoapwaterorothersolution
getsintotheinsidethepositivepressureregulatorand/oralarms,itmayincurequipment
malfunction.Takecautionasitmayleadtoseriousdanger.
6. Removingthefacepieceinadangerousplacecontaminatedbytoxicgasmayleadto
suffocationleadingtodeath.Alwaysmovetoasafeplacebeforeremovingthefacepiece.
7. Usingstrongdetergentsorcorrosiveagenttocleanthecylindermaycausedestruction
ofthecylinderduetothestress-corrosioncrackingphenomenon.Thismayleadto
serious injuries or death.
8. Usinganairrespiratorwithcrackedordamagedpositivepressureregulatormaycause
seriousinjuryordeath.Neverusesuchdefectiverespirator.Contactyourlocaldistributor
ormanufacturerforinspectionandrepair.
9. Usingthepositivepressureregulatorwatercontainedinitmayincureequipment
malfunction.Getridofmoistureorwaterinthepositivepressureregulatorbeforeuse.
10.Ifanytroubleoccursontheairrespirator,donotattempttorepairit.Contactyourlocal
distributorormanufacturerforinspectionandrepair.SanCheongshallnottakeany
responsibilityifanyaccidentoccursfromequipmentthathasnotbeenrepairedby
manufacturerorifpartsnotdesignatedbymanufacturerhavebeenused.
Caution
1. Theairrespiratorisdesignedforpersonswhoworkatthesiteofre,toxicgashandling
sites,orataplacewhereoxygenisshort.Neverusetheproductforotherthanthe
intended purposes.
2. Ifyoufeeldifcultyofbreathing,headacheordizziness,orsmellsomething,stopusing
immediatelyandchecktheconditionofyourhealthandthesafetyoftheairrespirator.
3. Thefacepieceismadeofsyntheticrubberandmaycausesideeffectstotheskinofthe
personallergictosuchmaterial.Ifyouareallergictosuchmaterials,donotwearthe
facepiece.
4. Theairrespiratorisheavyandlargercomparedwithotherordinarypersonalsafety
equipment.Ifyouusetheequipmentinanarrowplacewhereyouractivityislimited,you
maysuffercriticalinjuries.
5. Checkthehosefordamageorairleakfromconnectors.Ifanydefectsarediscovered,
contactyourlocaldistributorormanufacturerforinspectionandrepair.
6. Ifairleakisdiscoveredonthevalveorhoseconnectingparts,stopusingtheproduct
immediately,andcontactyourlocaldistributorormanufacturerforinspectionandrepair.
7. Seriousscratchesonthefaceshieldmayreducevisibilitywhichcreatingadanger.Replace
thefaceshieldimmediatelyifscratchedontheshield.
8. Inordertopreventobstructionofviewbybreathing,spreadanti-fogsolutiononinnerpart
ofthefaceshield.
9. Duetouser’sbodyfeaturessuchasbeard,hairandmustache,andtheglassesworn
bytheuser,thefacepiecemaynotperfectlyttheface.Ifthereisanygapbetween
thefacepieceandtheface,airmayleakoutrapidlyreducingthetimeofuse.
Takeextracautions.
10.Whenllingthehigh-pressurecylinder(hereinafterreferredtoas“cylinder”),checkand
replacetheaircompressorlterperiodicallytopreventforeignsubstancesfromgettinginto
the cylinder.
11. Always wear the air respirator in a clean air place.
12.If,duringtheprocessofusingtheairrespirator,thepositivepressureregulatorfails,
immediatelyopentheBy-passvalve(emergencyvalve)tocontinuebreathing.Escapeto
asafeplace,andcontactyourlocaldistributorormanufacturerforinspectionandrepair.
Warning
Caution
Serious body injuries or death may result when instructions are violated.
Materiallossorbodyinjuriesareexpectedwheninstructionsareviolated.
Caution
Warning

www.sancheong.com
06 07
SCBA
Caution
13. Incasetheexhaustvalvemalfunctionsduetothepresenceofforeignsubstances,it
causesdifcultyofbreathingorairtoleak.Contactyourlocaldistributorormanufacturer
forinspectionandrepair.
14. Never connect it to the high pressure regulator carrying other than the designated
capacity.
Eveniftheairrespiratorisappropriatelyused,personscannotbeprotectedinasituation
deviatingfromthereghtingairrespirator’smodelapprovalandtheapprovedinspection
technology levels.
Servicetimeismeasuredwhenapersonbreathes40ℓperminute.(Theoperationhourcanvary
signicantlydependingontheuser’sphysicalconditionandtheworkingenvironment.)
General specications
2
■ Product name: Self-ContainedBreathingApparatus
■ Model: SCA420,SCA680,SCA790
■ Applications: ThePositivepressureairrespiratorcanprotectthelifeofthe
reghters,workersandtherescuedfromthesitesofreandindustries.(However,
thelifeofthosewhousetheSCBAcanbeprotectedonlywithintherangeofthe
approvedmodelofthereghters’airrespiratorsandtheinspectiontechnology
levelapprovedbytheKoreaFireInstitute)
■ Standard performance: Theairrespiratorisaproductwhichhasacquiredmodel
approvalofthereghtingequipmentbytheKoreaFireInstitutepursuanttorelated
laws.ThecylinderhaspassedinspectionconductedbytheKGS(KoreaGasSafety
Corporation)andtheD.O.T.(DepartmentofTransportation)oftheU.S.A.
Approx.30min
7kg(w/oAir)
Approx.4.7liter
1,457liter
3.2Kg(w/ovalveandair)
Approx.45min
9kg(w/oAir)
Approx.6.8liter
2,040liter
3.6Kg(w/ovalveandair)
Approx.60min
11kg(w/oAir)
Approx.9.0liter
2,790liter
5.0Kg(w/ovalveandair)
Material
Water Vol.
Max.AirCapacity
Weight
Maximumlling
pressure(FP)
Internal pressure test
pressure(TP)
Standard
Service time
Weight
Typeofllinggas
Cylinder
310bar
517bar
300bar
500bar
310bar
517bar
Air
Carbon Composite
D.O.TandKGS
Item SCA420 SCA680 SCA790
Fillairintothecylinderonlyuptothemaximumllingpressure(FP).
(Basedonenvironmentwithatemperatureof35°C)
Caution
Caution
Caution
Warning

www.sancheong.com
06 07
SCBA
Caution
13. Incasetheexhaustvalvemalfunctionsduetothepresenceofforeignsubstances,it
causesdifcultyofbreathingorairtoleak.Contactyourlocaldistributorormanufacturer
forinspectionandrepair.
14. Never connect it to the high pressure regulator carrying other than the designated
capacity.
Eveniftheairrespiratorisappropriatelyused,personscannotbeprotectedinasituation
deviatingfromthereghtingairrespirator’smodelapprovalandtheapprovedinspection
technology levels.
Servicetimeismeasuredwhenapersonbreathes40ℓperminute.(Theoperationhourcanvary
signicantlydependingontheuser’sphysicalconditionandtheworkingenvironment.)
General specications
2
■ Product name: Self-ContainedBreathingApparatus
■ Model: SCA420,SCA680,SCA790
■ Applications: ThePositivepressureairrespiratorcanprotectthelifeofthe
reghters,workersandtherescuedfromthesitesofreandindustries.(However,
thelifeofthosewhousetheSCBAcanbeprotectedonlywithintherangeofthe
approvedmodelofthereghters’airrespiratorsandtheinspectiontechnology
levelapprovedbytheKoreaFireInstitute)
■ Standard performance: Theairrespiratorisaproductwhichhasacquiredmodel
approvalofthereghtingequipmentbytheKoreaFireInstitutepursuanttorelated
laws.ThecylinderhaspassedinspectionconductedbytheKGS(KoreaGasSafety
Corporation)andtheD.O.T.(DepartmentofTransportation)oftheU.S.A.
Approx.30min
7kg(w/oAir)
Approx.4.7liter
1,457liter
3.2Kg(w/ovalveandair)
Approx.45min
9kg(w/oAir)
Approx.6.8liter
2,040liter
3.6Kg(w/ovalveandair)
Approx.60min
11kg(w/oAir)
Approx.9.0liter
2,790liter
5.0Kg(w/ovalveandair)
Material
Water Vol.
Max.AirCapacity
Weight
Maximumlling
pressure(FP)
Internal pressure test
pressure(TP)
Standard
Service time
Weight
Typeofllinggas
Cylinder
310bar
517bar
300bar
500bar
310bar
517bar
Air
Carbon Composite
D.O.TandKGS
Item SCA420 SCA680 SCA790
Fillairintothecylinderonlyuptothemaximumllingpressure(FP).
(Basedonenvironmentwithatemperatureof35°C)
Caution
Caution
Caution
Warning

www.sancheong.com
08 09
SCBA
Conguration and features
3
Air cylinder
Low-pressure
warning alarm
Facepiece
coupling
Flashing locator light
Waist belt buckle
By-passvalve
Pressuregauge
Positivepressureregulator
Positivepressureregulator
detaching button
Facepiece strap
Faceshield
FBOClosebutton
Air switch handle
Cylinder valve
Rescue mask

www.sancheong.com
08 09
SCBA
Conguration and features
3
Air cylinder
Low-pressure
warning alarm
Facepiece
coupling
Flashing locator light
Waist belt buckle
By-passvalve
Pressuregauge
Positivepressureregulator
Positivepressureregulator
detaching button
Facepiece strap
Faceshield
FBOClosebutton
Air switch handle
Cylinder valve
Rescue mask

www.sancheong.com
10 11
SCBA
■Facepiece:Thefacepieceisconsistoffaceshield,regulatorreleasebutton,
speechdiaphragm,airswitchknob,exhalationvalve,headharnessandfacepiece
rubber.Theheadharnessisdesignedintheformofanetallowingcomfortable
feelingofwearandpreventingharnessfrombeingtwisted.
Thefacepieceismadeofsyntheticrubberandlargesingle-lensprovideswideview.
Theairswitchknobisanequipmentenablingwearertobreathewithambientair
whilewearingthefacepiece.(Neverputtheairswitchknobto“Ambientair”inan
areacontaminatedwithtoxicgas.)
■ Regulator:FBO(FirstBreathingOperation)systemallowstheSCBAtoactivate
withoutfreeow.Thisdevicereducesthepressure,whichhasbeenreducedrstby
theregulator,forthesecondtimetoalevelwhichissuitableforbreathing.Itmain-
tainsthepressureinsidethefacepiecetoalevelwhichishigherbyapproximately
20mmH2Othanthepressureoutsidethefacepiece,topreventthepollutedexternal
airgettingintotheinsidethefacepiece.
Incaseanerroroccursontheregular,theredBy-passvalve(emergencyvalve)
enables the user to receive the compressed air inside cylinder without breathing.
■ Regulator side button:Tostopusingtherespirator,pushthesidebuttonas
shown in the picture.
■ Regulator release buttons: Facepiece and regulator has disconnecting
structurewhichallowsusertoreleaseregulatorfromthefacepiecebypushingthe
two red buttons as shown in the picture
■ Pressure gauge: Luminous treatment is applied to the gauge so that user easi-
lycanrecognizeleakofremainingpressureinthedark.
■ Alarm:Thisdevicealertstheuserbygeneratinganalarmwhentheremaining
pressureofthecylinderisapproximately55bar,andtheusercanrecognizeinthe
noisyplacesuchasthesceneofare.
■ 1st stage regulator:Thisdevicesuppliesairtotheregulatorafterreducingthe
cylinderairtoapproximately8bar(8kgf/cm2).
■ Cylinder valve:Valveisequippedwithasafetydevicewhich
preventingburstoffthecylinderfromhightemperatureandovercharge.
Cylindervalvehasabuilt-inpressuregaugetocheckcylinderpressure
without opening valve.
■ Air cylinder: Composite cylinder made with aluminum liner and
wrappedwithcarbonberandberglass.
■ Flashing locator lights:Installedonbothsidesoftheharness,
isautomaticallyoperatedwhenthecylindervalveisopened.TheLED
lightsturnstoredwhentheremainingpressureislowerthanapproxi-
mately 55bar.
■ Shoulder strap:“S”typestructureprovidingcomfortablefeeling
ofwear.The“D”ring,installedonthestrap,allowsthestuffforres-
cue,suchaslantern,ropeandotherpersonalrescuedevices,tobe
equipped.
■ Waist belt buckle:One-touchtypestructureallowingquickand
easy connection.
■ Rescue mask:Thishalfnegativepressure(regulator)mask,con-
nectedtotheone-touchcouplingsocketattachedtotheharness,helps
thevictimbreathe.Thepushbuttononthecenterofthemasktoenable
simplearticialrespiration(*Optional)
■ Harness:Thisdeviceisusedtocarrythecylinderontheback.It
canbexedtothewaistbypullingthewaistbeltwithbothhands.In
order to ensure the air respirator user can work conveniently.

www.sancheong.com
10 11
SCBA
■Facepiece:Thefacepieceisconsistoffaceshield,regulatorreleasebutton,
speechdiaphragm,airswitchknob,exhalationvalve,headharnessandfacepiece
rubber.Theheadharnessisdesignedintheformofanetallowingcomfortable
feelingofwearandpreventingharnessfrombeingtwisted.
Thefacepieceismadeofsyntheticrubberandlargesingle-lensprovideswideview.
Theairswitchknobisanequipmentenablingwearertobreathewithambientair
whilewearingthefacepiece.(Neverputtheairswitchknobto“Ambientair”inan
areacontaminatedwithtoxicgas.)
■ Regulator:FBO(FirstBreathingOperation)systemallowstheSCBAtoactivate
withoutfreeow.Thisdevicereducesthepressure,whichhasbeenreducedrstby
theregulator,forthesecondtimetoalevelwhichissuitableforbreathing.Itmain-
tainsthepressureinsidethefacepiecetoalevelwhichishigherbyapproximately
20mmH2Othanthepressureoutsidethefacepiece,topreventthepollutedexternal
airgettingintotheinsidethefacepiece.
Incaseanerroroccursontheregular,theredBy-passvalve(emergencyvalve)
enables the user to receive the compressed air inside cylinder without breathing.
■ Regulator side button:Tostopusingtherespirator,pushthesidebuttonas
shown in the picture.
■ Regulator release buttons: Facepiece and regulator has disconnecting
structurewhichallowsusertoreleaseregulatorfromthefacepiecebypushingthe
two red buttons as shown in the picture
■ Pressure gauge: Luminous treatment is applied to the gauge so that user easi-
lycanrecognizeleakofremainingpressureinthedark.
■ Alarm:Thisdevicealertstheuserbygeneratinganalarmwhentheremaining
pressureofthecylinderisapproximately55bar,andtheusercanrecognizeinthe
noisyplacesuchasthesceneofare.
■ 1st stage regulator:Thisdevicesuppliesairtotheregulatorafterreducingthe
cylinderairtoapproximately8bar(8kgf/cm2).
■ Cylinder valve:Valveisequippedwithasafetydevicewhich
preventingburstoffthecylinderfromhightemperatureandovercharge.
Cylindervalvehasabuilt-inpressuregaugetocheckcylinderpressure
without opening valve.
■ Air cylinder: Composite cylinder made with aluminum liner and
wrappedwithcarbonberandberglass.
■ Flashing locator lights:Installedonbothsidesoftheharness,
isautomaticallyoperatedwhenthecylindervalveisopened.TheLED
lightsturnstoredwhentheremainingpressureislowerthanapproxi-
mately 55bar.
■ Shoulder strap:“S”typestructureprovidingcomfortablefeeling
ofwear.The“D”ring,installedonthestrap,allowsthestuffforres-
cue,suchaslantern,ropeandotherpersonalrescuedevices,tobe
equipped.
■ Waist belt buckle:One-touchtypestructureallowingquickand
easy connection.
■ Rescue mask:Thishalfnegativepressure(regulator)mask,con-
nectedtotheone-touchcouplingsocketattachedtotheharness,helps
thevictimbreathe.Thepushbuttononthecenterofthemasktoenable
simplearticialrespiration(*Optional)
■ Harness:Thisdeviceisusedtocarrythecylinderontheback.It
canbexedtothewaistbypullingthewaistbeltwithbothhands.In
order to ensure the air respirator user can work conveniently.

www.sancheong.com
12 13
SCBA
Before-use inspections
4
■ Mounting cylinder on harness
-Loosenthecylinderxingbandoftheharnesstolargerthanthecylindercircumference.
-Aimthecylindervalvetowardsthelowerpartoftheharness,andpushitintotheinsideofthe
xingband.
-Priortoconnectingthe1ststageregulatorwiththecylindervalve,checkthedamageordefects
ofO-ringattachedtotheinsidethe1st stage regulator connecting nuts.
-Connectthe1st stage regulator installed on the harness with the cylinder valve.
-Fixthecylinderrmlytotheharnesswiththecylinderxingband.
-Whenthecylindervalveisopenedagain,pressuregaugeindicatorshallnothaveanychanges.
-Ifthereisachangeinthepressuregauge,applysoapwatertotheconnectingpartsofthe
cylindervalvesafetydeviceandairoutlets,pressuregauge,hose,andalarms,andcheckfor
bubbles or drops.
-Ifairleaks,eventhecylindervalveand1ststageregulatorareaccuratelyconnected,checkthe
1ststageregulatoro-ring.CheckO-ringwhetherdamageormissing.
■ Leakage test
Cylinder
-Turnthecylindervalveon.
-Asthepressuregaugeindicatormaychangeduetothepressureexpandednearthehose,
carefullyturnthecylindervalvehandlecounterclockwisefor1ormoreturnsandremainsfor
approximately5~10minutes.
-Checkthepressuregaugereadingandturnthecylindervalvehandleclockwisetoclosethe
valve,andcheckthepressurechangeafterapproximately5~10minutes.
■ Pressure gauge and alarm
-Afteraleakagetest,completelyclosethecylindervalveandslowlyturntheBy-pass(tocounter-
clockwise)toopen.Thepressurebeginstodropbydrainingtheairinsidethehose.
-VerifythatRedLEDandalarmonharnessisgeneratedwherethepressuregaugeindicatesat
approximately55bar(5.5Mpa).
Ifanybubblesordropscontinuouslyappearontheconnectingparts,itindicatesairleaks
anddonotusetheequipment.Usingtheequipmentundersuchconditionmayleadtodrastic
air leak which reduces the operating hours rapidly and incurring danger. Contact your local
distributorormanufacturerforinspectionandrepair.
IfnoalarmorRedLEDasheswhenthepressuregaugeindicatorreachesapproximately
55bar,theairrespiratorwearermayinanextremelydangeroussituationastheescapetime
notbeingabletoidentify.Contactyourlocaldistributorormanufacturerforinspectionand
repair.
Caution
Caution
1.Firmlyxthecylindertotheharnesswhenwearingtheairrespirator.Failuretodosowill
allowthecylindertomoveorcomeofffromtheharnessthatcausingseriousinjuriesor
may put the wearer into the dangers.
2.Iftheexternalthreadofthecylindervalveandtheinternalthreadoftheregulatorarea
incorrectlyconnected,thescrewthreadortherubbermaybedamaged,allowingairto
leakfromthecylinder.
3.Toensurethecylinderisrmlyinstalledontheharness,buckleupinthefollowingmanner.
Front Side
2
1 3
4
Rear Side
Caution Warning

www.sancheong.com
12 13
SCBA
Before-use inspections
4
■ Mounting cylinder on harness
-Loosenthecylinderxingbandoftheharnesstolargerthanthecylindercircumference.
-Aimthecylindervalvetowardsthelowerpartoftheharness,andpushitintotheinsideofthe
xingband.
-Priortoconnectingthe1ststageregulatorwiththecylindervalve,checkthedamageordefects
ofO-ringattachedtotheinsidethe1st stage regulator connecting nuts.
-Connectthe1st stage regulator installed on the harness with the cylinder valve.
-Fixthecylinderrmlytotheharnesswiththecylinderxingband.
-Whenthecylindervalveisopenedagain,pressuregaugeindicatorshallnothaveanychanges.
-Ifthereisachangeinthepressuregauge,applysoapwatertotheconnectingpartsofthe
cylindervalvesafetydeviceandairoutlets,pressuregauge,hose,andalarms,andcheckfor
bubbles or drops.
-Ifairleaks,eventhecylindervalveand1ststageregulatorareaccuratelyconnected,checkthe
1ststageregulatoro-ring.CheckO-ringwhetherdamageormissing.
■ Leakage test
Cylinder
-Turnthecylindervalveon.
-Asthepressuregaugeindicatormaychangeduetothepressureexpandednearthehose,
carefullyturnthecylindervalvehandlecounterclockwisefor1ormoreturnsandremainsfor
approximately5~10minutes.
-Checkthepressuregaugereadingandturnthecylindervalvehandleclockwisetoclosethe
valve,andcheckthepressurechangeafterapproximately5~10minutes.
■ Pressure gauge and alarm
-Afteraleakagetest,completelyclosethecylindervalveandslowlyturntheBy-pass(tocounter-
clockwise)toopen.Thepressurebeginstodropbydrainingtheairinsidethehose.
-VerifythatRedLEDandalarmonharnessisgeneratedwherethepressuregaugeindicatesat
approximately55bar(5.5Mpa).
Ifanybubblesordropscontinuouslyappearontheconnectingparts,itindicatesairleaks
anddonotusetheequipment.Usingtheequipmentundersuchconditionmayleadtodrastic
air leak which reduces the operating hours rapidly and incurring danger. Contact your local
distributorormanufacturerforinspectionandrepair.
IfnoalarmorRedLEDasheswhenthepressuregaugeindicatorreachesapproximately
55bar,theairrespiratorwearermayinanextremelydangeroussituationastheescapetime
notbeingabletoidentify.Contactyourlocaldistributorormanufacturerforinspectionand
repair.
Caution
Caution
1.Firmlyxthecylindertotheharnesswhenwearingtheairrespirator.Failuretodosowill
allowthecylindertomoveorcomeofffromtheharnessthatcausingseriousinjuriesor
may put the wearer into the dangers.
2.Iftheexternalthreadofthecylindervalveandtheinternalthreadoftheregulatorarea
incorrectlyconnected,thescrewthreadortherubbermaybedamaged,allowingairto
leakfromthecylinder.
3.Toensurethecylinderisrmlyinstalledontheharness,buckleupinthefollowingmanner.
Front Side
2
1 3
4
Rear Side
Caution Warning

www.sancheong.com
14 15
SCBA
■ Flashing locator lights
- Lights
.Turncylindervalveonandcheckthelightsisactivated
.Ifthelightsareactivatedproperly,closethecylindervalveanddischargeairfromthefacepiece
hosecompletelybyusingtheBy-pass.
.Verifythatthelightsautomaticallyturnoffwhentheremainingpressureiscompletely
withdrawnfromthehose.
- Battery
.Thebatteryforashinglocatorlightsislocatedatthebottomoftheharness.
.Theaircylindershouldbedisconnectedfromtheharnessinordertochangethebattery.
.Whenthebatteryisexhausted,openthecoverbyunfasteningtheboltwithacross(+)
screwdriver,andreplacethe9Vbattery.
.Afterreplacingthebattery,xthegasketandclosethecover.Tightenthebolt.
(Ifthegasketisnotinthecorrectposition,thebatteryhousingmaynotbewaterproof.)
■ Air switch knob
-Ensureproperengagementbypullingontheregulator
toverifythatregulatorissecurelyattachedto
facepiece.
-Turntheairswitchknobtothe“Ambient air”position
andputthefacepieceon.
-Checkambientair(externalair)comesintofacepiece
as inhale.
-Turntheairswitchknobto“positivepressure
breathing”forlongperiodstorage.
■ Facepiece
-Checkthefacepieceforaccurateformandanydamage.
-Checkthefacepiecerubberpartsforanydamage.
-Checkthecleanlinessandtransparencyoffaceshield,andanti-fogsolutionisappliedornot.
-Makesurefacepieceandregulatorarermlyconnected.
-Checktheconditionoftheheadharnessanditselasticity.
-Afterwearingthefacepieceproperly,connecttheregulatoronthefacepieceandcloseairswitch
knob,theninhalesharply.Checkthefacepieceisslightlycollapsedtowardstheface.
■ Regulator
-Turnthecylindervalveonandcheckforanyairleakage.
-Afterturningtheairswitchknobto“positivepressurebreathing”,wearthefacepieceandinhale
sharplytostartairow,theregulatorwillturnonautomatically.
-Checktheairleakagewhenthewearerinsertsngerintothesideofthefacepieceduringthe
normal breathing.
-ChecktheBy-passbyturningtheredknobcounter-clockwiseuntilincreasedairowisfelt.
ClosetheBy-pass.
-Turntheairswitchknobtothedirectionof“Ambientair”;pushthesidebuttontostopthe
regulator.
1.Ifanyairleakisdiscoveredfromtheregulator,stopusingtheequipmentimmediately.
Contactyourlocaldistributorormanufacturerforinspectionandrepair.
2.IftheBy-passisnotactivatedevenaftertakingtheaboveprocedure,itcannotbeused
effectivelyinanemergency.Contactyourlocaldistributorormanufacturerforinspection
and repair.
Caution
Ifthelightisnotfunctioningproperlyeventhebatteryhasbeenreplaced,contactyourlocal
distributorormanufacturerforinspectionandrepair.
Caution
Usingthe“Ambient air”modeinaplacewithshortoxygen(oxygenconcentration18%orless)
orinaplacecontaminatedwithtoxicgasmayinduceseriousdamageofhealthordeath.Do
notusetheequipmentinthiskindofenvironment.Iftheairbreathingapparatusmalfunctions,
contactyourlocaldistributorormanufacturerforinspectionandrepair.
Beforedetachingordismountingtheregulatororrescuemask,Closethecylindervalve,turn
theredBy-passknobtocounter-clockwiseandcompletelydischargeremainingairfromthe
apparatushose.Iftheregulatorandtherescuemaskaredisconnectedordismountedwhileair
isinthehose,theO-ringinsidethecouplingsocketmaydamagedandairmayleakout.
Caution
Warning

www.sancheong.com
14 15
SCBA
■ Flashing locator lights
- Lights
.Turncylindervalveonandcheckthelightsisactivated
.Ifthelightsareactivatedproperly,closethecylindervalveanddischargeairfromthefacepiece
hosecompletelybyusingtheBy-pass.
.Verifythatthelightsautomaticallyturnoffwhentheremainingpressureiscompletely
withdrawnfromthehose.
- Battery
.Thebatteryforashinglocatorlightsislocatedatthebottomoftheharness.
.Theaircylindershouldbedisconnectedfromtheharnessinordertochangethebattery.
.Whenthebatteryisexhausted,openthecoverbyunfasteningtheboltwithacross(+)
screwdriver,andreplacethe9Vbattery.
.Afterreplacingthebattery,xthegasketandclosethecover.Tightenthebolt.
(Ifthegasketisnotinthecorrectposition,thebatteryhousingmaynotbewaterproof.)
■ Air switch knob
-Ensureproperengagementbypullingontheregulator
toverifythatregulatorissecurelyattachedto
facepiece.
-Turntheairswitchknobtothe“Ambient air”position
andputthefacepieceon.
-Checkambientair(externalair)comesintofacepiece
as inhale.
-Turntheairswitchknobto“positivepressure
breathing”forlongperiodstorage.
■ Facepiece
-Checkthefacepieceforaccurateformandanydamage.
-Checkthefacepiecerubberpartsforanydamage.
-Checkthecleanlinessandtransparencyoffaceshield,andanti-fogsolutionisappliedornot.
-Makesurefacepieceandregulatorarermlyconnected.
-Checktheconditionoftheheadharnessanditselasticity.
-Afterwearingthefacepieceproperly,connecttheregulatoronthefacepieceandcloseairswitch
knob,theninhalesharply.Checkthefacepieceisslightlycollapsedtowardstheface.
■ Regulator
-Turnthecylindervalveonandcheckforanyairleakage.
-Afterturningtheairswitchknobto“positivepressurebreathing”,wearthefacepieceandinhale
sharplytostartairow,theregulatorwillturnonautomatically.
-Checktheairleakagewhenthewearerinsertsngerintothesideofthefacepieceduringthe
normal breathing.
-ChecktheBy-passbyturningtheredknobcounter-clockwiseuntilincreasedairowisfelt.
ClosetheBy-pass.
-Turntheairswitchknobtothedirectionof“Ambientair”;pushthesidebuttontostopthe
regulator.
1.Ifanyairleakisdiscoveredfromtheregulator,stopusingtheequipmentimmediately.
Contactyourlocaldistributorormanufacturerforinspectionandrepair.
2.IftheBy-passisnotactivatedevenaftertakingtheaboveprocedure,itcannotbeused
effectivelyinanemergency.Contactyourlocaldistributorormanufacturerforinspection
and repair.
Caution
Ifthelightisnotfunctioningproperlyeventhebatteryhasbeenreplaced,contactyourlocal
distributorormanufacturerforinspectionandrepair.
Caution
Usingthe“Ambient air”modeinaplacewithshortoxygen(oxygenconcentration18%orless)
orinaplacecontaminatedwithtoxicgasmayinduceseriousdamageofhealthordeath.Do
notusetheequipmentinthiskindofenvironment.Iftheairbreathingapparatusmalfunctions,
contactyourlocaldistributorormanufacturerforinspectionandrepair.
Beforedetachingordismountingtheregulatororrescuemask,Closethecylindervalve,turn
theredBy-passknobtocounter-clockwiseandcompletelydischargeremainingairfromthe
apparatushose.Iftheregulatorandtherescuemaskaredisconnectedordismountedwhileair
isinthehose,theO-ringinsidethecouplingsocketmaydamagedandairmayleakout.
Caution
Warning

www.sancheong.com
16 17
SCBA
How to use air respirator
5
■ Before using the apparatus
1. Check pressure in the air cylinder through the cylinder valve
gauge.
2.Ensurecylindervalveisclosed
3.Ensureaircylinderisrmlyconnectedtotheharness(Referto
thesection“Before-useinspections”).
4. Check cylinder valve and the 1st stage regulator are correctly
connected.
5.Checkpressuregaugeontherightsideoftheharness
indicates0kgf/cm2.
6.Inserttheregulatorintothefacepieceandensureproper
engagement by pulling the regulator.
7.EnsuretheBy-passworksproperly(turntheredBy-passknob
tocounterclockwiseuntilincreasedtheairowthenclosetheBy-
passknobaftercheck).
8.Putonthemountedaircylinderharness.
9.Usingbothhands,pulltheadjustingstrapuntiltheharnessis
comfortablyworn.
10.Connectthewaistbuckle,andthenpullandadjustthewaist
belttotthewaistcomfortably.
11. Connectthecheststrapbuckle,andtightenthestrap.
12.Connectthefacepiecehoseplugtothecouplingsocket.
13.Settheairswitchknobonthe“PositivePressureBreathing”
position.
Todisconnectcoupling,holdandpress
No.2inthedirectionofthecouplingsocket
No.1.PulltheNo.1couplingsocketinthe
samedirection(tothedirectionmarkedwith
anarrowonthecouplingsocket).
1 2

www.sancheong.com
16 17
SCBA
How to use air respirator
5
■ Before using the apparatus
1. Check pressure in the air cylinder through the cylinder valve
gauge.
2.Ensurecylindervalveisclosed
3.Ensureaircylinderisrmlyconnectedtotheharness(Referto
thesection“Before-useinspections”).
4. Check cylinder valve and the 1st stage regulator are correctly
connected.
5.Checkpressuregaugeontherightsideoftheharness
indicates0kgf/cm2.
6.Inserttheregulatorintothefacepieceandensureproper
engagement by pulling the regulator.
7.EnsuretheBy-passworksproperly(turntheredBy-passknob
tocounterclockwiseuntilincreasedtheairowthenclosetheBy-
passknobaftercheck).
8.Putonthemountedaircylinderharness.
9.Usingbothhands,pulltheadjustingstrapuntiltheharnessis
comfortablyworn.
10.Connectthewaistbuckle,andthenpullandadjustthewaist
belttotthewaistcomfortably.
11. Connectthecheststrapbuckle,andtightenthestrap.
12.Connectthefacepiecehoseplugtothecouplingsocket.
13.Settheairswitchknobonthe“PositivePressureBreathing”
position.
Todisconnectcoupling,holdandpress
No.2inthedirectionofthecouplingsocket
No.1.PulltheNo.1couplingsocketinthe
samedirection(tothedirectionmarkedwith
anarrowonthecouplingsocket).
1 2

www.sancheong.com
18 19
SCBA
14. Loosen all the harness straps. Grip the bottom straps. Insert
chinintothelowerpartoffacepiece,thenpulltheharnessback
overthehead.Pullthebackofharnessdownwarduntilcentered
atthebackofthehead.
15.Tightenthetwolowerstrapsrstbypullingthemstraight
back,notout.Tightenthefacepieceuntilthemaskissnugagainst
theface.Tightenthetwosidetemplestrapsinthesamemanner
asbefore.Ensurethatthefacepiecetabsarenottuckedunder
thefaceseal.
18.PuttheAirSwitchknobtothe“positivepressurebreathing”
position.Inhalesharplytostarttheairow.
19.MakesuretheBy-passvalveisworkingproperly(Count-
er-clockwisetheBy-passvalvetoreleasetheair,itmeansnormal
operationand,whenyounishtotestvalveclockwisetolock)
20.Tocheckthepositivepressureinsidethefacepiece,insertthe
ngerintothesideofthefacepiece,andseeifairleaksoutside
thefacepiece.
21.Checkthefunctioningofthefacepiecebeforeuse.
16.Turnontheaircylindervalvecompletely.
17.Ensurethepressuregaugeindicatesover270bar.
AbruptopeningoftheaircylindervalvemaycausedamagetothehoseortotherubberO-ring
inside the connecting parts.
Ifthepressuregaugereadslessthan270bars,theairrespiratoroperatingtimemaybeless
thanservicetimepresentedbymanufacturer.
Caution
Caution
1.Ifyoupulltheheadadjustingstraplocatedintheuppercentertoostrongtoxthefacepiece
totheface,agapwillbecreatedonthefrontuppersideoffacepieceandlosingthet.
2.Iftheshapeofthefaceisextraordinary,thefaceandthefacepiecemightnotbeattachedto
eachothercompletely,itmaycauseairleak.
Caution
Ifthefacepieceisnotproperlytafterworn,youcannotbeprotectedfromtoxicgas,sodonot
enteradangerousareacontaminatedwithtoxicgas.Contactyourlocaldistributorormanufac-
turerforinspectionandrepair.
Warning

www.sancheong.com
18 19
SCBA
14. Loosen all the harness straps. Grip the bottom straps. Insert
chinintothelowerpartoffacepiece,thenpulltheharnessback
overthehead.Pullthebackofharnessdownwarduntilcentered
atthebackofthehead.
15.Tightenthetwolowerstrapsrstbypullingthemstraight
back,notout.Tightenthefacepieceuntilthemaskissnugagainst
theface.Tightenthetwosidetemplestrapsinthesamemanner
asbefore.Ensurethatthefacepiecetabsarenottuckedunder
thefaceseal.
18.PuttheAirSwitchknobtothe“positivepressurebreathing”
position.Inhalesharplytostarttheairow.
19.MakesuretheBy-passvalveisworkingproperly(Count-
er-clockwisetheBy-passvalvetoreleasetheair,itmeansnormal
operationand,whenyounishtotestvalveclockwisetolock)
20.Tocheckthepositivepressureinsidethefacepiece,insertthe
ngerintothesideofthefacepiece,andseeifairleaksoutside
thefacepiece.
21.Checkthefunctioningofthefacepiecebeforeuse.
16.Turnontheaircylindervalvecompletely.
17.Ensurethepressuregaugeindicatesover270bar.
AbruptopeningoftheaircylindervalvemaycausedamagetothehoseortotherubberO-ring
inside the connecting parts.
Ifthepressuregaugereadslessthan270bars,theairrespiratoroperatingtimemaybeless
thanservicetimepresentedbymanufacturer.
Caution
Caution
1.Ifyoupulltheheadadjustingstraplocatedintheuppercentertoostrongtoxthefacepiece
totheface,agapwillbecreatedonthefrontuppersideoffacepieceandlosingthet.
2.Iftheshapeofthefaceisextraordinary,thefaceandthefacepiecemightnotbeattachedto
eachothercompletely,itmaycauseairleak.
Caution
Ifthefacepieceisnotproperlytafterworn,youcannotbeprotectedfromtoxicgas,sodonot
enteradangerousareacontaminatedwithtoxicgas.Contactyourlocaldistributorormanufac-
turerforinspectionandrepair.
Warning

www.sancheong.com
20 21
SCBA
■ After use
1.Uponcompletionofusingtheapparatus,keepawayfromthetoxicgasareacompletely.
Turntheairswitchknobtothe“Ambient air”positionandthenpushtheregulatorside
button.
2.Pullandloosenthefacepiece’sharnessstrap,andremovethefacepiecestartingfromthe
chin.
3.Disconnectcheststrapbuckleandunfastenwaistbelt.
4.Pullthestrapclampupwardtoloosenthestrap.
5.Putdowntheharnesscarefully,trynottoapplyimpacttothecylinder.
6.Closethecylindervalve,anddrainairoutofthehoseuntilthepressuregaugeindicates
0kgf/cm2byusingtheBy-pass.ThenclosetheBy-pass.
7.Disconnectthefacepiecehosefromthecouplingsocket.
8.Checkthefacepieceandtheairrespiratorforanysignofmalfunction.
■ Cleaning
1.Closetheaircylindervalvecompletely,anddrainallpressureremainingintheairrespirator
hose.
2.Usingapieceofsoftcloth,cleanandremoveforeignmaterialsfromthefacepiece,cylinder,
hose and harness.
3.Cleanthefacepieceonlyafterremovingtheregulator.
4.Forcleaningsolution,usemildsoapwithwarmwater.Dipapieceofsoftclothintothediluted
solutionandcleanthefacepiece,cylinder,hoseandharness.
5.Soakasoftclothintowarmwaterandcleanthefacepiece,cylinder,hoseandharness.
6.Usingadriedcloth,removeremainingwaterfromthefacepiece,cylinder,hoseandharness.
7.Storeapparatusinwell-ventilatedplaces.Keepawayfromheatanddirectsunlight.
8.Tocleanthefaceshield,usedriedandsoftclothwithextracare.
9.Removeandcleantheforeignmaterialsfromtheleftandrightwaistbeltadjustingframeof
theharness.Iftheframeisnotproperlyworking,cleantheframewithasortofoilpaper.
■ For use the rescue mask
1. Connect the rescue mask to the harness socket.
2. As the rescue mask is operated in the negative
pressuresystem,airissuppliedfromtheair
respirator only when the wearer inhales air.
3. Ifthewearerneedslargeamountofair,press
thebuttonlocatedontheuppercenterofthe
rescue mask.
Cleaning and inspection after use
6
If,afterconnectingtherescuemask,2personsusetheapparatussimultaneously,theactualair
respiratoroperationtimewillbereducedsignicantlythanthetimepresentedbythemanufac-
turer.Precautiousduringuse.
1.Donotuseacetone,benzene,chemicalproductsorgasolineandothertypeofsolvents
tocleantheproduct.Usingsuchmaterialstocleantheproductmaycausedamagetothe
product.
2.Donotsoakanyofthevalves,positivepressureregulator,high-pressureregulatorand
hoseinthewater.Anymoistureorwaterexistinginsideanyofsuchpartsmayinducefault
whileusingtheequipment,placingtheuserindanger.
3.Donotusestrongdetergentsorcorrosiveagent(suchasacidorbasicsolutionandother
chemicalproducts)tocleanthecylinder.Usingsuchmaterialstocleanthecylindermay
causedestructionofthecylinderduetothestress-corrosioncrackingphenomenon.
Thismayleadtoseriousinjuriesordeath.
Caution
Caution