Nitrite Low Range Preliminary examination:
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please notify your Dealer.
Each HI 707 meter is supplied complete with:
• Two Sample Cuvettes and Caps
• Six packets of Nitrite LR Reagent
• 1 x 1.5V AAA Battery
• Instruction Manual
HI 707
Functional description:
Errors and warnings:
Light High: There is too much light to perform a measurement.
Please check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement. Please
check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0” indicates that the sample absorbs less
light than the zero reference. Check the procedure and make sure you
use the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the
meter.
1. Dust cover.
2.Cuvette with cap.
3.Cuvette holder.
4.Liquid Crystal Display.
5.Button.
For more details about spare parts and accessories
see “Accessories”.
Dear Customer,
Thank you for choosing a Hanna Instruments Product.
Please read this instruction manual carefully before using the instrument. If you need
additional technical information, do not hesitate to e-mail us at [email protected] or
view our worldwide contact list at www.hannainst.com.
Technical specifications:
Range 0 to 600 ppb
Resolution 1 ppb
Accuracy ±20 ppb ±5% of reading @ 25 °C / 77 °F
Light Source Light Emitting Diode @ 470 nm
Light Detector Silicon Photocell
Method Adaptation of the
EPA Diazotization method 354.1
. The
reaction between nitrite and the reagent causes a pink tint
in the sample.
Environment 0 to 50 °C (32 to 122 °F);
max 95% RH non-condensing
Battery Type 1 x 1.5V AAA
Auto-Shut off After 10 minutes of non-use
Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.)
•Turn the meter on by pressing the button. All
segments will be displayed. When the display
shows “Add”, “C.1” with “Press” blinking,
the meter is ready.
•Fill the cuvette with 10 mL of unreacted
sample and replace the cap. Place the cuvette
into the meter and close the meter’s cap.
•Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the meter
is zeroed.
•Remove the cuvette from the meter and
unscrew the cap. Add the content of one packet
of HI 707-0 reagent. Replace the cap and
shake gently for 15 seconds. Place the cuvette
back into the meter.
•Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement) or,
alternatively, wait for 15 minutes and press
the button.
Note: Between 15 and 10 minutes the timer
will be displayed in minutes and under
10 minutes timer is expressed in minutes
and seconds.
•The instrument displays concentration in ppb
of NO2¯-N.
•To convert the displayed concentration to the
nitrite ion concentration (NO2¯), multiply the
reading by 3.29. To convert the NO2¯-N
concentration to sodium nitrite (NaNO2)
multiply the reading by 4.93. The meter
automatically turns off after 10 minutes.
10 mL
•It is important that the sample does not contain any debris.
•Whenever the cuvette is placed into the measurement cell, it must be dry
outside, and completely free of fingerprints, oil and dirt. Wipe it thoroughly with
HI 731318 or a lint-free cloth prior to insertion.
•Shaking the cuvette can generate bubbles, causing higher readings. To obtain
accurate measurements, remove bubbles by swirling or by gently tapping the
cuvette.
•Do not let the reacted sample stand for too long after reagent is added, as
accuracy will be affected.
•After the reading it is important to immediately discard the sample, otherwise
the glass might become permanently stained.
REAGENT SETS
HI 707-25 Reagent for 25 Nitrite Low Range tests
OTHER ACCESSORIES
HI 707-11 Nitrite LR Certified Standard Kit
HI 731318 Cloth for wiping cuvettes (4 pcs.)
HI 731321 Glass cuvettes (4 pcs.)
HI 731225 Cuvette black cap for checker HC (4 pcs.)
HI 731353 Cuvette seal cap for checker HC (4 pcs.)
HI 740028 1.5V AAA batteries (4 pcs.)
HI 93703-50 Cuvette cleaning solution (230 mL)
Recommendations for Users
Before using this product, make sure that it is entirely suitable for your specific application and for the
environment in which it is used.
Operation of this instrument may cause unacceptable interferences to other electronic equipment,
thus requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance.
To avoid damage or burns, do not put the instrument in microwave oven. For the safety of you and the
instrument do not use or store the instrument in hazardous environments.
Hanna Instruments reserves the right to modify the design, construction, or
appearance of its products without advance notice.
Battery management
To save the battery, the instrument shuts down after 10 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead the
instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
•Turn the instrument off by holding the button until the meter shuts off.
•Turn the instrument upside down and remove the battery cover with a screwdriver.
•Remove the battery from its location and replace it with a new one, inserting the
negative end first.
•Insert the battery cover and replace the screw with a screwdriver.
IST707 03/13
Measurement procedure: Accessories:Tips for an accurate measurement

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI96719C User manual

Hanna Instruments

Hanna Instruments HI96719C User manual

Hanna Instruments HI736 User manual

Hanna Instruments

Hanna Instruments HI736 User manual

Hanna Instruments HI 83215 User manual

Hanna Instruments

Hanna Instruments HI 83215 User manual

Hanna Instruments HI 96804 User manual

Hanna Instruments

Hanna Instruments HI 96804 User manual

Hanna Instruments HI 4221 User manual

Hanna Instruments

Hanna Instruments HI 4221 User manual

Hanna Instruments HI98161 User manual

Hanna Instruments

Hanna Instruments HI98161 User manual

Hanna Instruments Checker HI717 User manual

Hanna Instruments

Hanna Instruments Checker HI717 User manual

Hanna Instruments HI702 User manual

Hanna Instruments

Hanna Instruments HI702 User manual

Hanna Instruments HI 98171 User manual

Hanna Instruments

Hanna Instruments HI 98171 User manual

Hanna Instruments Checker HI772 User manual

Hanna Instruments

Hanna Instruments Checker HI772 User manual

Hanna Instruments HI 93703-11 User manual

Hanna Instruments

Hanna Instruments HI 93703-11 User manual

Hanna Instruments Checker HI 711 User manual

Hanna Instruments

Hanna Instruments Checker HI 711 User manual

Hanna Instruments HI 8014 User manual

Hanna Instruments

Hanna Instruments HI 8014 User manual

Hanna Instruments HI 771 User manual

Hanna Instruments

Hanna Instruments HI 771 User manual

Hanna Instruments HI 9813-5 User manual

Hanna Instruments

Hanna Instruments HI 9813-5 User manual

Hanna Instruments LP 2000 User manual

Hanna Instruments

Hanna Instruments LP 2000 User manual

Hanna Instruments HI 83099 User manual

Hanna Instruments

Hanna Instruments HI 83099 User manual

Hanna Instruments HI764 User manual

Hanna Instruments

Hanna Instruments HI764 User manual

Hanna Instruments HI723 User manual

Hanna Instruments

Hanna Instruments HI723 User manual

Hanna Instruments PRIMO 3 User manual

Hanna Instruments

Hanna Instruments PRIMO 3 User manual

Hanna Instruments HI 4105 User manual

Hanna Instruments

Hanna Instruments HI 4105 User manual

Hanna Instruments HI98163 User manual

Hanna Instruments

Hanna Instruments HI98163 User manual

Hanna Instruments pHep+ HI 98108 User manual

Hanna Instruments

Hanna Instruments pHep+ HI 98108 User manual

Hanna Instruments HI 93102 User manual

Hanna Instruments

Hanna Instruments HI 93102 User manual

Popular Measuring Instrument manuals by other brands

TPI 623 instruction manual

TPI

TPI 623 instruction manual

Nieaf Instruments NI 15 manual

Nieaf Instruments

Nieaf Instruments NI 15 manual

Precision Digital Corporation ProtEX-MAX PD8-6200 Series instruction manual

Precision Digital Corporation

Precision Digital Corporation ProtEX-MAX PD8-6200 Series instruction manual

VERO LT R3 CE user manual

VERO

VERO LT R3 CE user manual

Meters UK SmartLink 45 manual

Meters UK

Meters UK SmartLink 45 manual

SICK SLT060-0B010J700 manual

SICK

SICK SLT060-0B010J700 manual

Fluke IRR2-BT user manual

Fluke

Fluke IRR2-BT user manual

Radiation Alert MONITOR 4 Operation manuals

Radiation Alert

Radiation Alert MONITOR 4 Operation manuals

Kane KANE200 manual

Kane

Kane KANE200 manual

Pintek DP-800HS instruction manual

Pintek

Pintek DP-800HS instruction manual

Agilent Technologies E8362 user guide

Agilent Technologies

Agilent Technologies E8362 user guide

Sealey VSE5863 instructions

Sealey

Sealey VSE5863 instructions

Tektronix WVR7200 Declassification and security instructions

Tektronix

Tektronix WVR7200 Declassification and security instructions

Endress+Hauser Proservo NMS80 Brief operating instructions

Endress+Hauser

Endress+Hauser Proservo NMS80 Brief operating instructions

sewerin SeCorrPhon AC 200 Quick reference guide

sewerin

sewerin SeCorrPhon AC 200 Quick reference guide

Satlink WS-6922 manual

Satlink

Satlink WS-6922 manual

Electronic 63 quick start guide

Electronic

Electronic 63 quick start guide

GE Grid Solutions Multilin 9450 instruction manual

GE Grid Solutions

GE Grid Solutions Multilin 9450 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.