Hanna Instruments HI 719 User manual

Magnesium Hardness Preliminary examination:
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please notify your Dealer.
Each HI 719 meter is supplied complete with:
• Two Sample Cuvettes and Caps
• Reagents set for 50 tests
• 1 x 1.5V AAA Battery
• Instruction Manual
HI 719
Functional description:
Errors and warnings:
Light High: There is too much light to perform a measurement.
Please check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement.
Please check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0.00” indicates that the sample absorbs
less light than the zero reference. Check the procedure and make sure
you use the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the
meter.
1. Dust cover.
2. Cuvette with cap.
3. Cuvette holder.
4. Liquid Crystal Display.
5. Button.
For more details about spare parts and accessories
see “Accessories”.
Dear Customer,
Thank you for choosing a Hanna Instruments Product.
Please read this instruction manual carefully before using the instrument. If you need
additional technical information, do not hesitate to e-mail us at [email protected]
or view our worldwide contact list at www.hannainst.com.
www.hannainst.com
Technical specifications:
Range 0.00 to 2.00 ppm
Resolution 0.01 ppm
Accuracy ±0.20 ppm ±5% of reading @ 25 °C / 77 °F
Light Source Light Emitting Diode @ 525 nm
Light Detector Silicon Photocell
Method Adaptation of the
Standard Methods for the Examination
of Water and Wastewater, 18th edition
, EDTA colorimetric
method. The reaction between magnesium and reagents
causes a reddish-violet tint in the sample.
Environment 0 to 50 °C (32 to 122 °F);
max 95% RH non-condensing
Battery Type 1 x 1.5V AAA
Auto-Shut off After 10 minutes of non-use
Dimensions 86 x 61 x 37.5 mm (3.38 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.)
[email protected]
www.ponpe.com
•Turn the meter on by pressing the button. All
segments will be displayed. When the display
shows “Add”, “C.1” with “Press” blinking,
the meter is ready.
•Rinse a graduated beaker several times with
unreacted sample, before filling it to the 50 mL
mark with sample.
•Add 0.5 mL of HI 719A-0 reagent, swirl to mix.
•Add 0.5 mL of HI 719B-0 reagent, swirl to mix.
•Use this solution to rinse 2 cuvettes. Fill both
cuvettes up to the 10 mL mark.
•Add 1 drop of HI 719C-0 reagent to one
cuvette (#1), replace the cap and invert the
cuvette several times to mix. This is the blank.
•Add 1 drop of HI 719D-0 reagent to the
second cuvette (#2), replace the cap and
invert the cuvette several times to mix. This is
the sample.
•Place the blank (#1) into the meter and
close the meter’s cap.
•Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the meter
is zeroed.
•Remove the cuvette.
•Insert the second cuvette (#2) into the meter
and press the button.
•The meter directly displays the concentration of
magnesium hardness (CaCO3) in ppm. The meter
automatically turns off after 10 minutes.
REAGENT SETS
HI 719-25 Reagent set for 50 Magnesium Hardness Tests
OTHER ACCESSORIES
HI 719-11 Magnesium Hardness Certified Standard Kit
HI 731318 Cloth for wiping cuvettes (4 pcs.)
HI 731321 Glass cuvettes (4 pcs.)
HI 731225 Black cuvette cap for checker HC (4 pcs.)
HI 731353 Cuvette seal for checker HC (4 pcs.)
HI 740028 1.5V AAA batteries (4 pcs.)
HI 93703-50 Cuvette cleaning solution (230 mL)
Recommendations for Users
www.hannainst.com
Hanna Instruments reserves the right to modify the design, construction or
appearance of its products without advance notice.
Battery management
IST719 04/15
Measurement procedure: Accessories:Tips for an accurate measurement
For additional information, contact your
dealer or the nearest
Hanna Customer Service Center.
To find a Hanna Office in your area,
visit our web site:
•It is important that the sample does not contain any debris.
•Whenever the cuvette is placed into the measurement cell, it must be dry
outside, and completely free of fingerprints, oil and dirt. Wipe it thoroughly with
HI 731318 or a lint-free cloth prior to insertion.
•Shaking the cuvette can generate bubbles, causing higher readings. To obtain
accurate measurements, remove bubbles by swirling or by gently tapping the
cuvette.
•Do not let the reacted sample stand for too long after reagent is added, as
accuracy will be affected.
•After the reading it is important to immediately discard the sample, otherwise
the glass might become permanently stained.
To save the battery, the instrument shuts down after 10 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead
the instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
•Turn the instrument off by holding the button until the meter shuts off.
•Turn the instrument upside down and remove the battery cover with a screwdriver.
•Remove the battery from its location and replace it with a new one, inserting the
negative end first.
•Insert the battery cover and replace the screw with a screwdriver.
Before using this product, make sure that it is entirely suitable for your specific application and for the
environment in which it is used.
Operation of this instrument may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance.
To avoid damage or burns, do not put the instrument in microwave oven. For the safety of you and the
instrument do not use or store the instrument in hazardous environments.
10 mL
#1
10 mL
#2
#1
#2
#1
#2
[email protected]
www.ponpe.com

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI96704C User manual

Hanna Instruments

Hanna Instruments HI96704C User manual

Hanna Instruments HI733 User manual

Hanna Instruments

Hanna Instruments HI733 User manual

Hanna Instruments Chromium VI User manual

Hanna Instruments

Hanna Instruments Chromium VI User manual

Hanna Instruments HI83303 User manual

Hanna Instruments

Hanna Instruments HI83303 User manual

Hanna Instruments HI 93739 User manual

Hanna Instruments

Hanna Instruments HI 93739 User manual

Hanna Instruments HI 93706 User manual

Hanna Instruments

Hanna Instruments HI 93706 User manual

Hanna Instruments HI 96715C User manual

Hanna Instruments

Hanna Instruments HI 96715C User manual

Hanna Instruments HI96739C User manual

Hanna Instruments

Hanna Instruments HI96739C User manual

Hanna Instruments HI 991001 User manual

Hanna Instruments

Hanna Instruments HI 991001 User manual

Hanna Instruments HI 98128 User manual

Hanna Instruments

Hanna Instruments HI 98128 User manual

Hanna Instruments Checktemp 1 User manual

Hanna Instruments

Hanna Instruments Checktemp 1 User manual

Hanna Instruments HI 4104 User manual

Hanna Instruments

Hanna Instruments HI 4104 User manual

Hanna Instruments HI 96710C User manual

Hanna Instruments

Hanna Instruments HI 96710C User manual

Hanna Instruments HI981520 User manual

Hanna Instruments

Hanna Instruments HI981520 User manual

Hanna Instruments HI 250 User manual

Hanna Instruments

Hanna Instruments HI 250 User manual

Hanna Instruments HI 83203 User manual

Hanna Instruments

Hanna Instruments HI 83203 User manual

Hanna Instruments HI 4101 User manual

Hanna Instruments

Hanna Instruments HI 4101 User manual

Hanna Instruments HI 8043 User manual

Hanna Instruments

Hanna Instruments HI 8043 User manual

Hanna Instruments HI 96701C User manual

Hanna Instruments

Hanna Instruments HI 96701C User manual

Hanna Instruments Conmet1 (HI 98305 User manual

Hanna Instruments

Hanna Instruments Conmet1 (HI 98305 User manual

Hanna Instruments Chromium VI User manual

Hanna Instruments

Hanna Instruments Chromium VI User manual

Hanna Instruments HI 4110 User manual

Hanna Instruments

Hanna Instruments HI 4110 User manual

Hanna Instruments HI 253 User manual

Hanna Instruments

Hanna Instruments HI 253 User manual

Hanna Instruments HI 713 User manual

Hanna Instruments

Hanna Instruments HI 713 User manual

Popular Measuring Instrument manuals by other brands

QUARTA RADEX ONE user manual

QUARTA

QUARTA RADEX ONE user manual

Katronic KATflow 170 Operating and safety instructions

Katronic

Katronic KATflow 170 Operating and safety instructions

Lumel N30P user manual

Lumel

Lumel N30P user manual

Easy-Laser E980 manual

Easy-Laser

Easy-Laser E980 manual

Elcontrol STAR 3 user manual

Elcontrol

Elcontrol STAR 3 user manual

Agilent Technologies NFA Series Setup guide

Agilent Technologies

Agilent Technologies NFA Series Setup guide

Endress+Hauser nivotester FTC 420 Quick installation guide

Endress+Hauser

Endress+Hauser nivotester FTC 420 Quick installation guide

Flybox Omnia57-80 Series manual

Flybox

Flybox Omnia57-80 Series manual

bmcm AMS42-LAN16fx manual

bmcm

bmcm AMS42-LAN16fx manual

Schäfer RMS 442 quick start guide

Schäfer

Schäfer RMS 442 quick start guide

PCB Piezotronics 352A21/NC Installation and operating manual

PCB Piezotronics

PCB Piezotronics 352A21/NC Installation and operating manual

Schaller humimeter BMA user manual

Schaller

Schaller humimeter BMA user manual

THEIS TKL-7 operating instructions

THEIS

THEIS TKL-7 operating instructions

HYDROMETER IZAR CENTER user manual

HYDROMETER

HYDROMETER IZAR CENTER user manual

Omega HHF143 user guide

Omega

Omega HHF143 user guide

amc VIBRO AVM 1002D user manual

amc VIBRO

amc VIBRO AVM 1002D user manual

Mollet LF20 Series Instruction

Mollet

Mollet LF20 Series Instruction

DayTronic 3000PLUS instruction manual

DayTronic

DayTronic 3000PLUS instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.