Chromium VI High Range Preliminary examination:
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please notify your Dealer.
Each HI 723 meter is supplied complete with:
• Two Sample Cuvettes and Caps
• Six packets of Chromium VI HR Reagent
• 1 x 1.5V AAA Battery
• Instruction Manual
HI 723
Technical specifications:
Range 0 to 999 ppb
Resolution 1 ppb
Accuracy ±5 ppb ±4% of reading @ 25 °C / 77 °F
Light Source Light Emitting Diode @ 525 nm
Light Detector Silicon Photocell
Method Adaptation of the
ASTM Manual of Water and Environmental
Technology, D1687-92
, Diphenylcarbohydrazide method.
The reaction between chromium VI and the reagent
causes a purple tint in the sample.
Environment 0 to 50 °C (32 to 122 °F);
max 95% RH non-condensing
Battery Type 1 x 1.5V AAA
Auto-Shut off After 10 minutes of non-use
Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.)
Functional description:
Errors and warnings:
Light High: There is too much light to perform a measurement.
Please check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement.
Please check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0” indicates that the sample absorbs less
light than the zero reference. Check the procedure and make sure you
use the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the
meter.
1. Dust cover.
2. Cuvette with cap.
3. Cuvette holder.
4. Liquid Crystal Display.
5. Button.
For more details about spare parts and accessories
see “Accessories”.
www.hannainst.com
Dear Customer,
Thank you for choosing a Hanna Instruments Product.
Please read this instruction manual carefully before using the instrument. If you need
additional technical information, do not hesitate to e-mail us at [email protected]
or view our worldwide contact list at www.hannainst.com.
www.ponpe.com
[email protected]
•Turn the meter on by pressing the button.
All segments will be displayed. When the
display shows “Add”, “C.1” with “Press”
blinking, the meter is ready.
•Fill the cuvette with 10 mL of unreacted
sample and replace the cap. Place the cuvette
into the meter and close the meter’s cap.
•Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the
meter is zeroed.
•Remove the cuvette from the meter and
unscrew the cap. Add the content of one
packet of HI 723-25 reagent. Replace
the cap and shake vigorously for about
10 seconds. Place the cuvette back into the
meter.
•Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement) or,
alternatively, wait for 6 minutes and press the
button.
•The instrument displays concentration in ppb
of chromium VI. The meter automatically turns
off after 10 minutes.
INTERFERENCE
Interference may be caused by:
Vanadium above 1 ppm: to remove the interference
wait 10 minutes before reading
Mercury (Hg2
2+/Hg2+) above 200 mg/L
Molybdenum (Mo6+) above 200 mg/L
10 mL
•It is important that the sample does not contain any debris.
•Whenever the cuvette is placed into the measurement cell, it must be dry
outside, and completely free of fingerprints, oil and dirt. Wipe it thoroughly with
HI 731318 or a lint-free cloth prior to insertion.
•Shaking the cuvette can generate bubbles, causing higher readings. To obtain
accurate measurements, remove bubbles by swirling or by gently tapping the
cuvette.
•Do not let the reacted sample stand for too long after reagent is added, as
accuracy will be affected.
•After the reading it is important to immediately discard the sample, otherwise
the glass might become permanently stained.
REAGENT SETS
HI 723-25 Reagent for 25 Chromium VI High Range tests
OTHER ACCESSORIES
HI 723-11 Chromium VI HR Certified Standard Kit
HI 731318 Cloth for wiping cuvettes (4 pcs.)
HI 731321 Glass cuvettes (4 pcs.)
HI 731225 Cuvette black cap for checker HC (4 pcs.)
HI 731353 Cuvette seal cap for checker HC (4 pcs.)
HI 740028 1.5V AAA batteries (4 pcs.)
HI 93703-50 Cuvette cleaning solution (230 mL)
Recommendations for Users
Before using this product, make sure that it is entirely suitable for your specific application and for the
environment in which it is used.
Operation of this instrument may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance.
To avoid damage or burns, do not put the instrument in microwave oven. For the safety of you and the
instrument do not use or store the instrument in hazardous environments.
For additional information, contact your
dealer or the nearest
Hanna Customer Service Center.
To find a Hanna Office in your area,
visit our web site:
www.hannainst.com
Hanna Instruments reserves the right to modify the design, construction or
appearance of its products without advance notice.
Battery management
To save the battery, the instrument shuts down after 10 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead
the instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
•Turn the instrument off by holding the button until the meter shuts off.
•Turn the instrument upside down and remove the battery cover with a screwdriver.
•Remove the battery from its location and replace it with a new one, inserting the
negative end first.
•Insert the battery cover and replace the screw with a screwdriver.
IST723 03/13
Measurement procedure: Accessories:Tips for an accurate measurement
[email protected]
www.ponpe.com

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI 96761C User manual

Hanna Instruments

Hanna Instruments HI 96761C User manual

Hanna Instruments HI 83141V User manual

Hanna Instruments

Hanna Instruments HI 83141V User manual

Hanna Instruments HI9064 User manual

Hanna Instruments

Hanna Instruments HI9064 User manual

Hanna Instruments HI 93728 User manual

Hanna Instruments

Hanna Instruments HI 93728 User manual

Hanna Instruments HI 96761C User manual

Hanna Instruments

Hanna Instruments HI 96761C User manual

Hanna Instruments HI723 User manual

Hanna Instruments

Hanna Instruments HI723 User manual

Hanna Instruments HYGROCHECK HI 98601 User manual

Hanna Instruments

Hanna Instruments HYGROCHECK HI 98601 User manual

Hanna Instruments HI83326 User manual

Hanna Instruments

Hanna Instruments HI83326 User manual

Hanna Instruments Checker HI 711 User manual

Hanna Instruments

Hanna Instruments Checker HI 711 User manual

Hanna Instruments AquaDip User manual

Hanna Instruments

Hanna Instruments AquaDip User manual

Hanna Instruments HI739 User manual

Hanna Instruments

Hanna Instruments HI739 User manual

Hanna Instruments HI83303 User manual

Hanna Instruments

Hanna Instruments HI83303 User manual

Hanna Instruments BL 983327-0 User manual

Hanna Instruments

Hanna Instruments BL 983327-0 User manual

Hanna Instruments HI 981410 User manual

Hanna Instruments

Hanna Instruments HI 981410 User manual

Hanna Instruments HI97101 User manual

Hanna Instruments

Hanna Instruments HI97101 User manual

Hanna Instruments HI 96813 User manual

Hanna Instruments

Hanna Instruments HI 96813 User manual

Hanna Instruments HI 93713 User manual

Hanna Instruments

Hanna Instruments HI 93713 User manual

Hanna Instruments HI 2209 User manual

Hanna Instruments

Hanna Instruments HI 2209 User manual

Hanna Instruments HI96802 User manual

Hanna Instruments

Hanna Instruments HI96802 User manual

Hanna Instruments HI97737 User manual

Hanna Instruments

Hanna Instruments HI97737 User manual

Hanna Instruments HI96802 User manual

Hanna Instruments

Hanna Instruments HI96802 User manual

Hanna Instruments HI 9026 User manual

Hanna Instruments

Hanna Instruments HI 9026 User manual

Hanna Instruments HI 99300 User manual

Hanna Instruments

Hanna Instruments HI 99300 User manual

Hanna Instruments HI 8730 User manual

Hanna Instruments

Hanna Instruments HI 8730 User manual

Popular Measuring Instrument manuals by other brands

Voltmaster FCM1 operating manual

Voltmaster

Voltmaster FCM1 operating manual

SICK FLOWSIC100 Flare operating instructions

SICK

SICK FLOWSIC100 Flare operating instructions

NDT James Instruments Aquameter T-M-170 Operator's manual

NDT James Instruments

NDT James Instruments Aquameter T-M-170 Operator's manual

Northern Industrial Tools 486781 owner's manual

Northern Industrial Tools

Northern Industrial Tools 486781 owner's manual

Medisana HG 100 instruction manual

Medisana

Medisana HG 100 instruction manual

Triplett CableRater instruction manual

Triplett

Triplett CableRater instruction manual

BT Redcare GSM STU EV User's installation guide

BT Redcare

BT Redcare GSM STU EV User's installation guide

Sealey VSE9540 manual

Sealey

Sealey VSE9540 manual

Deviser DS2400T Operation manual

Deviser

Deviser DS2400T Operation manual

UEi C161 instruction manual

UEi

UEi C161 instruction manual

Endress+Hauser Proline 10 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline 10 Brief operating instructions

Radians Innova EnviroMentor Field Finder User instructions

Radians Innova

Radians Innova EnviroMentor Field Finder User instructions

Extech Instruments 45160 user guide

Extech Instruments

Extech Instruments 45160 user guide

THORLABS M2MS-BC106N Series quick start

THORLABS

THORLABS M2MS-BC106N Series quick start

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Saluki Technology S3302A datasheet

Saluki Technology

Saluki Technology S3302A datasheet

RADIOMETER FLEX ABL90 Reference manual

RADIOMETER

RADIOMETER FLEX ABL90 Reference manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.