•Iftheuserusetheproductwithmethodsotherthanspecifiedbythemanufacturer,there
maybebodilyinjuriesorpropertydamages.
•To prevent electric shock or equipment failure, please do not turn on the power until
completingwiring.
•Neverdisassemble,modify,orrepairtheproduct.Thereisapossibilityofamalfunction,
anelectricshock,orariskoffire.
•Pleaseturnoffthepowerwhenmounting/dismountingoftheproduct.Thisisacauseof
anelectricshock,amalfunction,orfailure.
•Topreventdamageorfailureofthisproduct,pleasesupplytheratedpowervoltage.
•Since this is not explosion-proof structure,pleasedonot use in a place where
combustibleorexplosivegasisaround.
•Sincethereisapossibilityofanelectricshock,pleaseusetheproductasmountedona
panelwhilethepowerisbeingsupplied.
WARNING
CAUTION
Specification
Powersupplyvoltage
5Vd.c. 12-24Vd.c.
Powerconsumption
Approx.3W Approx.5W
Insulationresistance
10㏁min(500Vd.c.)
Dielectricstrenght 1,500VACfor1min(powerterminal-inputterminal)
Noiseresistance Powersupplyterminalnormalmode±200V
Powersupplyterminalcommonmode±500V
Vibration
durability
10-55㎐Peakamplitudefor2hourseachinX,Y,Zdirections
Shock
durability
300㎨(Approx30G)
Ambienttemperature
0~50℃
Ambienthumidity 35~85%RH
Storagetemperature
-10~70℃
Measurementrange
DCvoltage
DCvoltage
DCcurrent
DCcurrent
Model
Measurementrange
Resolvingpower Inputimpedance
Maxallowableinput
voltage
BA1-ND10-1 199.9㎷100㎶100㏀70V
BA1-ND10-2 1.999V1㎷1㏁100V
BA1-ND10-3 19.99V10㎷1㏁250V
BA1-ND10-4 199.9V100㎷10㏁300V
Model
Input Displayrange Inputimpedance
Maxallowableinput
voltage
BA1-ND11-1
1-5VDC
50.0 100㏀100V
BA1-ND11-2 100.0 100㏀100V
BA1-ND11-3 199.9 100㏀100V
Model
Input Displayrange Inputimpedance
Maxallowableinput
current
BA1-ND21-1
4-20㎃DC
50.0 25Ω150㎃
BA1-ND21-2 100.0 50Ω150㎃
BA1-ND21-3 199.9 100Ω150㎃
Model
Measurementrange
Resolvingpower Inputimpedance
Maxallowableinput
current
BA1-ND20-1 199.9㎂0.1㎂1㏀1㎃
BA1-ND20-2 1.999㎃1㎂100Ω50㎃
BA1-ND20-3 19.99㎃10㎂10Ω150㎃
BA1-ND20-4 199.9㎃100㎂ 1Ω300㎃
BA1-ND20-5 1.999A1㎃
Useshunt
(secondaryvoltage50㎷)
BA1-ND20-6 19.99A10㎃
BA1-ND20-7 199.9A100㎃
BA1-ND20-8 1999A1A
※Accuracy:±0.2%ofindicationvalue±1digit(23℃±5℃)
※Accuracy:±0.2%ofindicationvalue±1digit(23℃±5℃)
※Accuracy:±0.2%ofindicationvalue±1digit(23℃±5℃)
※Accuracy:±0.2%ofindicationvalue±1digit(23℃±5℃)
•Thecontentsoftheinstructionmanualaresubjectivetochangewithoutpriornotice.
•Pleasemakesurethatthespecificationisthesameaswhatyouhaveordered.
•Pleasemakesurethattheproductisnotdamagedduringshipping.
•Pleaseusethisproductinaplacewherecorrosivegas(suchasharmfulgas,ammonia,
etc.)andflammablegasdonotoccur.
•Pleaseusethisproductinaplacewherethereisnodirectvibrationandalargephysical
impacttotheproduct.
•Pleaseusethisproductinaplacewherethereisnowater,oil,chemicals,steam,dust,
salt,ironorothers(Contaminationclass1or2).
•Pleasedonotwipethisproductwithorganicsolventssuchasalcohol,benzeneand
others.(Pleaseusemilddetergent)
•Pleaseavoidplaceswhereexcessiveamountsofinductiveinterferenceandelectrostatic
andmagneticnoiseoccur.
•Pleaseavoidplaceswhereheataccumulationoccursduetodirectsunlightorradiantheat.
•Pleaseusethisproductinaplacewheretheelevationisbelow2,000m.
•Pleasemakesuretoinspecttheproductifexposedtowatersincethereisapossibilityof
anelectricleakageorariskoffire.
•Itiseffectiveagainstnoiseifmakingthepowerlinesoftheproductthetwistedpairwiring.
•Pleasedonotconnectanythingtotheunusedterminals.
•Pleaseconnectwiresproperlyaftermakingsurethepolarityofterminal.
•Pleaseinstallaswitchorbreakneartheoperatortofacilitateitsoperation.
•Writedownonalabelthattheoperationofcircuitbreakerorswitchdisconnectsthepower
sincethedeviseisinstalled.
•Inordertousethisproductproperlyandsafely,werecommendperiodicmaintenance.
•Somepartsofthisproducthavelimitedexpectedlifespanandageddeterioration.
•Thewarrantyofthisproduct(includingaccessories)is1yearonlywhenitisusedforthe
purposeitwasintendedundernormalcondition.
 Digitalpanelmeter

BA1
ThankyouforpurchasingHANYOUNGproduct.
Pleasecheckwhethertheproductistheexactlysameasyouordered.
Beforeusingtheproduct,pleasereadthisinstructionmanualcarefully.
Pleasekeepthismanualwhereyoucanviewatanytime
INSTRUCTIONMANUAL
MF0204KE230407
HANYOUNGNUX CO.,LTD
HEADOFFICE
28,Gilpa-ro71beon-gil,Michuhol-gu,Incheon,Korea
TEL:+82-32-876-4697
http://www.hanyoungnux.com
Donottouchorcontacttheinput/outputterminalsbecauseitmay
causeelectricshock.
DANGER
Safetyinformation
Beforeusingtheproduct,please readthe safetyinformationthoroughlyand use it properly.Alerts
declaredinthemanualareclassifiedtoDanger,WarningandCautionbytheircriticality
DANGERindicatesanimminentlyhazardoussituation
which,ifnotavoided,willresultindeathorseriousinjury
WARNINGindicatesapotentiallyhazardoussituation
which,ifnotavoided,couldresultindeathorserious
injury
CAUTIONindicatesapotentiallyhazardoussituation
which,ifnotavoided,mayresultinminorormoderate
injury
DANGER
WARNING
CAUTION
Suffixcode
Model
Code Description
BA1-  - -  iniDCindicator48(W)×24(H)㎜
Output N instructiononly
Input D
10 DCvoltage(voltmeter)
20 DCcurrent(ammeter)
11 DCvoltmeter(1-5VDC)
21 DCammeter(4-20㎃DC)
Rangecode 1~8 Refertothemeasurementrangecode
Powersupplyvoltage -Noindication:5Vd.c.
A12-24Vd.c.
Function
Connectiondiagram
Dimensionsandpannelcutout
Selectdecimalposition
Repairandinspection
AfterService
Powersupplyconnection
Digital
Panelmeter
Twinshieldcable
Input
<Figure1>
<Figure2>
Input Digital
Panelmeter Motivepower
●Pleaseusethebacksideterminalfordecimalpositionselection.
●Whenturningon1.999decimalpoint,pleaseconnecttoterminalnumber
7(COM)andnumber4terminalwhicharecommonterminalsofdecimal
point.
•Pleasekeepthedeviceunderthe60%humiditywithinthetemperature
-10to+70.Pleasegetridofthedustwhenusingitinthedustyplaces.
(Themachine'slifeisshortenedduetohightemperatureofcomponents
inthedevice).
•Pleasebecautiousnottotouchthinnerandvolatileoilsincethis
instrument'scaseismoldedplastic.
Thisproductisreleasedoutafterproduction,testing,andexamination
throughastrictqualitycontrol.Ifithasbrokendown,pleasecontactthe
dealerorourheadquartersdirectly.(Pleasesendthedefectiveproductwith
thedetailedinformationaboutit.)
[Unit:㎜]
•Forinputsignal(directvoltageor4-20mAd.c.or1-5Vd.c.),
pleaseconnecttoterminalnumber8andterminalnumber10.
•Fortheconnectionwireusetwopiecesofshieldwireandconnectshield
toterminalnumber8.(Refertofigure2)
•Connectpowertothepowerterminal.
•Connect"+"tonumber1terminaland"-"tonumber2terminalforpower
5Vd.c.Usethepowerwithin±5%of5Vd.c.
•Evenusingthepreventiondeviceagainstnoisedependingonthetypes,
itisverydifficulttoequiptheabsolutepreventiondevicetosuchasmall
equipmentlikeadigitalpanelmeter.
Input'sconnection
※WhenusingmorethanoneBA1,pleaseuseseparatepowersupply.
Pleasebecautiousthat②and⑧terminalsareinternallyshort.
<Figure1>IncaseyouuseSMPS.
ThisnoiseproblemdoesnothappenwithallSMPS,butiftherequirements
arenotmet,youcanseetheeffectbyaddingthecondensertothedriving
powersource,asbelow.
●
Dimensions
●
Panelcutout
Inputsignal Voltage,current,currentloop(4-20㎃d.c.or1-5Vd.c.)
A/Dconversiontype Duplexintegraltype
Samplingcycle 300㎳
Responsespeed Approx.2sec(maxrange)
Maxdisplayabledigit ±1999
Displayingpart 7segmentsLED
Decimalpoint
indication
10¹,10²and10³indicationbythebacksideterminalconnection
Polarityindication Display“-”automaticallywheninputsignalisopposite.
Indicationwhen
rangeisexceeded Indicatewith
Indicationwhen
rangeisshort Indicatewith
DCsignalinput

This manual suits for next models

18

Other HANYOUNG NUX Measuring Instrument manuals

HANYOUNG NUX ED6 User manual

HANYOUNG NUX

HANYOUNG NUX ED6 User manual

HANYOUNG NUX TP3 User manual

HANYOUNG NUX

HANYOUNG NUX TP3 User manual

HANYOUNG NUX GE Series User manual

HANYOUNG NUX

HANYOUNG NUX GE Series User manual

HANYOUNG NUX GR200 Series User manual

HANYOUNG NUX

HANYOUNG NUX GR200 Series User manual

HANYOUNG NUX HN100 Series User manual

HANYOUNG NUX

HANYOUNG NUX HN100 Series User manual

HANYOUNG NUX BS6 User manual

HANYOUNG NUX

HANYOUNG NUX BS6 User manual

HANYOUNG NUX HL Series User manual

HANYOUNG NUX

HANYOUNG NUX HL Series User manual

HANYOUNG NUX BS Series User manual

HANYOUNG NUX

HANYOUNG NUX BS Series User manual

HANYOUNG NUX TP3 User manual

HANYOUNG NUX

HANYOUNG NUX TP3 User manual

HANYOUNG NUX PF3 User manual

HANYOUNG NUX

HANYOUNG NUX PF3 User manual

HANYOUNG NUX LP1 User manual

HANYOUNG NUX

HANYOUNG NUX LP1 User manual

HANYOUNG NUX BA 1 Series User manual

HANYOUNG NUX

HANYOUNG NUX BA 1 Series User manual

HANYOUNG NUX MP3-4 H Series User manual

HANYOUNG NUX

HANYOUNG NUX MP3-4 H Series User manual

HANYOUNG NUX HDM3 User manual

HANYOUNG NUX

HANYOUNG NUX HDM3 User manual

HANYOUNG NUX HE Series User manual

HANYOUNG NUX

HANYOUNG NUX HE Series User manual

HANYOUNG NUX MP3 User manual

HANYOUNG NUX

HANYOUNG NUX MP3 User manual

HANYOUNG NUX TP3 User manual

HANYOUNG NUX

HANYOUNG NUX TP3 User manual

HANYOUNG NUX HP3 User manual

HANYOUNG NUX

HANYOUNG NUX HP3 User manual

HANYOUNG NUX BK3 User manual

HANYOUNG NUX

HANYOUNG NUX BK3 User manual

HANYOUNG NUX MP3 User manual

HANYOUNG NUX

HANYOUNG NUX MP3 User manual

HANYOUNG NUX RP3 User manual

HANYOUNG NUX

HANYOUNG NUX RP3 User manual

Popular Measuring Instrument manuals by other brands

Tektronix RSA306 Installation and safety instructions

Tektronix

Tektronix RSA306 Installation and safety instructions

KROHNE VA40 Supplementary instructions

KROHNE

KROHNE VA40 Supplementary instructions

Hach ANATEL PAT700 user manual

Hach

Hach ANATEL PAT700 user manual

S+S Regeltechnik KFF-SD operating instructions

S+S Regeltechnik

S+S Regeltechnik KFF-SD operating instructions

Hach sensION+ user manual

Hach

Hach sensION+ user manual

Mark-10 E Series quick start guide

Mark-10

Mark-10 E Series quick start guide

Bender ISOMETER iso685W-D-P manual

Bender

Bender ISOMETER iso685W-D-P manual

Fluidwell F070 manual

Fluidwell

Fluidwell F070 manual

TPI PGM100 instruction manual

TPI

TPI PGM100 instruction manual

Endress+Hauser RIA 550 operating instructions

Endress+Hauser

Endress+Hauser RIA 550 operating instructions

Rohm F-senso 1255729 user guide

Rohm

Rohm F-senso 1255729 user guide

Fluke 971 user manual

Fluke

Fluke 971 user manual

Desco 19258 Installation, operation and maintenance

Desco

Desco 19258 Installation, operation and maintenance

Huvitz CR-9000 Operation manual

Huvitz

Huvitz CR-9000 Operation manual

Satec C191HM Installation and operation manual

Satec

Satec C191HM Installation and operation manual

Honeywell DR 4300 Replacement Instruction

Honeywell

Honeywell DR 4300 Replacement Instruction

olympia electronics BS-634 user manual

olympia electronics

olympia electronics BS-634 user manual

SEFRAM MW3518 user manual

SEFRAM

SEFRAM MW3518 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.