Oakwood Woodburning Stove
Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/1523-90-08327
Hearth&HomeTechnologieswelcomesyoutoourtraditionofexcellence!BychoosingaHarmanappliance,youhavebecome
partofourcommitmenttomeetingtheheatingneedsofconsumerswiththemostdistinctive,powerfulandresponsiblehome
heatingproductsavailable.
TheOakwoodhashugefeaturesinanelegantlysmallpackage,theOakwoodtakesadvantageofHarman’s30+yearsof
stovedesign,technologyandmanufacturing.TheFiredomesecondarycombustionsystemprovidesforsuper-cleanburning
andminimalmaintenance.Thetop-loadingfeaturemakesformoreconvenientloading,withenoughfuelforanalldayburn.
Wewishyouandyourfamilymanyyearsofenjoymentinthewarmthandcomfortofyourhearthappliance.
ThankyouforchoosingHarman.
ThisLabelislocatedontherearoftheappliance.Itcontainsimportantsafetytestinformationaswellastheclearancesto
combustiblematerials.Thelabelalsocontainstheapplianceserialnumber.Foryourrecords,copyyourserialnumberand
purchasedatehere.
DateofPurchase:________________________ Serial#:________________________
Non approuvé pour utilisation dans portables / Manufactured Homes
"Empêcher MAISON incendies" Installer et utiliser uniquement en conformité avec installation et
d'utilisation les instructions du fabricant et les codes locaux. En l'absence de codes locaux, l'installation
doit satisfaire aux exigences minimales de la norme NFPA 211 aux Etats-Unis. Reportez-vous aux
instructions du fabricant et les codes locaux pour les précautions nécessaires pour faire passer la
cheminée à travers un mur ou un plafond combustible.
Ce poêle à bois doit inspection périodique et la réparation pour un fonctionnement correct. Consultez
le manuel du propriétaire pour plus d'informations. Ce est contre les règlements fédéraux pour faire
fonctionner ce poêle à bois d'une manière incompatible avec les instructions d'utilisation dans le manuel
du propriétaire.
Tuyau de raccordement de fumée doit être de 6 "de diamètre, en acier au minimum 24 MSG bleu.
Cheminée doit être construite l'usine 103HT ou la construction de maçonnerie. Contactez Immeuble
Local ou fonctionnaires incendie au sujet des restrictions et l'inspection d'installation dans votre région.
NE PAS brancher l'appareil à une cheminée desservant un autre APPAREIL.
Pour une utilisation avec Solid combustible bois Seulement, Ne pas brûler de charbon.
Émissions certiés EPA: 2,3 g / h
Type de carburant: Cordon bois
NE SURCHAUFFEZ - Si le connecteur chauffe ou de la cheminée rougeoie, vous surchauffez.
Route cordon électrique de l'appareil.
Fonctionner uniquement avec les portes fermées
Remplacer le verre seulement avec de la céramique 5mm, disponible chez votre revendeur.
Ne pas obstruer le ux d'air sous l'appareil.
DANGER: risque d'incendie ou d'explosion - Ne pas brûler de déchets, de l'essence, vidanger
l'huile ou d'autres liquides inammables.
AVERTISSEMENT: Risque d'incendie, ne pas fonctionner avec chargement de combustible ou
d'enlèvement de cendres portes ouvertes.
Ne pas stocker carburants ou de combustibles dans les dégagements marqués. Inspectez
et cheminée propre et le connecteur régulièrement - Dans certaines conditions d'utilisation,
l'accumulation de créosote peut se produire rapidement.
Le Bypass amortisseur doit être ouvert avant d'ouvrir ne importe quelle porte de charge ou de
la cendre.
Ne pas installer une grille ou autrement surélever le feu.
BARCODE LABEL
008
Serial No.
Node série:
Rev EP.N. 3-90-249
352 Mountain House Road
Halifax, PA 17032
ECO: 78093
PART # / REV: 3-90-249_RevE
ORIGINATOR: SpidleT
DATE: 06/15
LABEL SIZE: 9.5 in. x 8.75 in.
LOCATION: Rear Heat Shield
CLASS:
ADHESIVE: 468
MATERIAL: METAL
INK: BLACK
OVERCOAT:
LABEL TICKET
Corners .062
Report #/Rapport #135-S-11-2
Tested to/Testé selon: UL 1482-1996, UL 737-1996, ULC-S627-00, EPA Method 28 & 5G
Not approved For Use in Mobile/Manufactured Homes
“PREVENT HOUSE FIRES” Install and use only in accordance with manufacturer’s installation and operation
instructions and local codes. In absence of local codes, installation must meet minimum requirements of NFPA
211 in USA. Refer to manufacturer’s instructions and local codes for precautions required for passing chimney
through a combustible wall or ceiling.
This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s manual for
further information. It is against federal regulations to operate this wood heater in a manner inconsistent with the
operating instructions in the owner’s manual.
Flue connector pipe must be 6” diameter, minimum 24 MSG blue steel. Chimney must be factory built 103HT
or masonry construction. Contact Local Building or Fire Ofcials about restrictions and installation inspection
in your area.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SERVING ANOTHER APPLIANCE.
FOR USE wITH SOLID wOOD FUEL ONLY, DO NOT BURN COAL.
EPA Certied Emissions: 2.3 g/hr
Fuel Type: Cord Wood
DO NOT Overre - If Heater or chimney connector glows, you are overring.
Route power cord away from unit.
OPERATE ONLY wITH DOORS CLOSED
Replace glass only with 5mm ceramic, available from your dealer.
Do not obstruct airow under the appliance.
DANGER: Risk of Fire or Explosion - Do not burn garbage, gasoline, drain oil or other ammable liquids.
WARNING: Risk of Fire, Do not operate with fuel loading or ash removal doors open.
Do not store fuel or combustibles within marked clearances. Inspect and clean chimney and connector
regularly - Under certain conditions of use, creosote buildup may occur rapidly.
The Bypass Damper must be opened prior to opening any load or ash door.
Do not install a grate or otherwise elevate the re.
DO NOT REMOVE THIS LABEL / Ne pas enlever cette étiquette
MODEL / MODÈLE: “Oakwood” Woodburning Stove
Room Heater Solid Fuel Burning Type
NOT SUITABLE FOR MOBILE-HOME INSTALLATION
Date of Manufacture / Date de fabrication:
2015 2016 2017 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032
US ENVIRONMENTAL PROTECTION AGENCY
Certied to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020.
Certié conforme aux normes 2015 d’émission de particules. Non approuvé pour la vente après le 15 mai 2020.
Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-
d’Amérique par des pièces d’origine américaine et pièces importées.
ATTENTION:
FONCTIONNEMENT- NE TOUCHEZ PAS L’APPAREIL-
GARDEZ LES ENFANTS ET LES VÊTEMENTS ÉLOIGNÉS-
TOUT CONTACT PEUT ENTRAÎNER DES BRÛLURES DE
LA PEAU. RÉFÉREZ-VOUS À LA PLAQUE SIGNALÉTIQUE
ET AU MODE D’EMPLOI. GARDEZ LE MOBILIER ET LES
AUTRES MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART
DE L’APPAREIL.
CAUTION:HOT wHILE IN OPERATION- DO
NOT TOUCH- kEEP CHILDREN AND CLOTHING AwAY-
CONTACT MAY CAUSE SkIN BURNS- SEE NAMEPLATE
AND INSTRUCTIONS. kEEP FURNISHINGS AND
OTHER COMBUSTIBLE MATERIALS A CONSIDERABLE
DISTANCE AwAY FROM THE APPLIANCE
CLEARANCE TO COMBUSTIBLE SURFACE
A - Unit to Side Wall 26” (660mm)
B - Unit to Back Wall 28” (711mm)
C - Chimney Connector to Side Wall 38” (965mm)
D - Chimney Connector to Back Wall 32” (813mm)
E - Unit to Adjacent wall 24” (610mm)
F - Chimney Connector to Adjacent wall 32” (813mm)
*See manual for additional installation congurations.
ESPACES LIBRES AUX COMBUSTIBLES
A - Du mur de côté à l’appareil 26” (660mm)
B - Du mur arrière àl’appareil 28” (711mm)
C - Du tuyau de cheminée au mur de côté 38” (965mm)
D - Du tuyau de cheminée au mur arrière 32” (813mm)
E - Entre le mur adjacent et l’appareil 24” (610mm)
F - Entre la tuyau et le mur adjacent 32” (813mm)
* Voir le manuel pour d’autres congurations d’installation
Floor protection must be a 3/4” min. thickness, non-combustible material
having an equal or better insulating value (lower k value) of k=.84 BTU/In
Ft2Hr °F, extending beneath heater and to front/sides/rear as indicated. In
Canada, required oor protection must be 18” (450mm) in front.
Leprotecteur de plancher doit être d’une epaisseur minimum de 3/4” d’un
material incombustible ayant une valeur d’isolation de k=.84 BTU/in Ft2Hr
°F. Il doit s’etendre et à l’arriêre de l’appareil comme indiquè. ‘Au Canada, la
preotection du plancher doit s’étendre de 18” (450mm) en avant.
BACKWALL
SIDEWALL
A
C
B
D
ADJACENT WALL
ADJACENT WALL
E
F
BACKWALL
SIDEWALL
A
C
B
D
ADJACENT WALL
ADJACENT WALL
E
F
8”
8”
8”
16”
A
C
B
D
ADJACENT WALL
ADJACENT WALL
E
F
8”
8”
8”
16”