Thank you for purchasing our product “Exidéal mini”. Please read this manual carefully then use our product.
The warranty is included on the back side of this manual. Please keep it safe.
Haslux Co., Ltd.
Cover Page
P.1-P.2 Safety & Notes
P.3-P.4 Contents of Package/Parts
P.5-P.6 Exidéal mini Features
P.7-P.10 Exidéal mini Operation Method
4 Care Program
P.11-P.12 Q&A/Troubleshooting
P.13 After-sales servicing
包装内容/各部分的名称和功能
P.5-P.6 Exidéal的特点
P.7-P.8 Exidéal的操作步骤说明
Warranty

1
Please read this instruction manual carefully and use the product safely and correctly.
■These notes provide instruction on the safe and correct use of our product and to prevent
injury and damage.
■Below are the classifications for these notes.
Caution classification
Danger
Warning
Caution
Explanation of Figure
This symbol indicates acts prohibited.
Persons who use heart pacemaker or electro-medical apparatus may cause malpractice. Please
do not use this product.
Danger
Warning
Please close your eyes during irradiation, even use it with goggles sold separately. Please do not use
anything other than Exideal dedicated goggles.
Please do not use this product on the face or body for any purpose other than beauty treatment. Do not
use the damaged product.
Please do not use on the following body parts.
●Acne and suppuration ●Other than the specified parts ●Scars ●Itching, sunshine, and pathological stains
caused by physical irritation ●Facial melasma ●Dermatitis caused by skin care product ● Mucous
membranes in the mouth ●Excessive sunburn
Do not use if the cord or adaptor is damaged, hot, or loosely plugged into an electrical outlet.
There is a risk of fire, electric shock, short circuit, and burns.
Please do not damage, bend, pull, stretch, kink, or place heavy objects on power cords. There is a risk of
fire, electric shock, short circuit, and burns.
Please use electricity rated at 100-240V power code and use the Exidéal mini dedicated AC adaptor. There
is a risk of fire, electric shock, or malfunction.
Please remove glasses and contact lenses. It may cause an accident or trouble.
Please remove earrings, necklaces, and any kinds of accessories. It may cause an accident or trouble.
Please avoid using in the following. If not avoided, it may result in serious injury or skin problems.
●Epileptic Seizures from the flashing light ●Cardiovascular Disease ●Acute Disease ●Allergen ●Fever disease
●Sensitive Skin ●Photosensitivity ●Abnormal Blood Pressure ●Hemophilia ●Infectious Diseases
●Tuberculous Disease ●Malignant tumor ●Facial neuralgia skin ●Telangiectasia caused by steroid hormones
and liver dysfunction ●Drinking or taking medicine ●Immediately after excessive sunburn, red, tingling and
inflamed ●Experience of getting a rash from chemical fibers ●During menstruation ●Pregnant ●Fatigue
This symbol Indicates a mandatory action that must be followed.
Safety & Notes
prohibit
prohibit

2
Please do not place this product in the bathroom, near too much moisture, or next to water.
(lavatory vanity) It could be a fire hazard, short circuit, or cause insulation deterioration.
Warning
In the following cases, stop using the product, turn off the power, and disconnect the adaptor.
There is a risk of burns due to fire or abnormal output.
●Smoke from the product ●Unusual heat ●Unusual noise ●Unusual smell, etc.
Please do not modify or re-assemble without the assistance of a repair engineer. It could result in
injury or fire.
Do not soak this product in water. There is a risk of electric shock or short circuit.
Please do not remove AC adaptor with wet hands. It could cause a short circuit or result in an
electric shock.
The machine contains a strong infrared pulse program. Remote control devices that use infrared
rays, such as TVs and air conditioners, may not work. If malfunction occurs or the remote control
cannot be used, turn off the power of the machine.
Please keep out of the reach of children. It could cause an accident or other problems.
Please set the operating time for a short duration if you are a first-time user or have sensitive
skin. Also check your skin during the session to avoid an accident or other possible problems.
Please follow the instruction manual for usage time and frequency. If not, it may cause an
accident or trouble.
Please stop using if you feel any pain or illness. It may cause an accident or trouble.
Please be sure to do a patch-test before using basic cosmetics.
Please avoid using it on the same area on the day of hair removal and shaving.
It may cause swelling or redness.
Caution
The angle of the LED irradiation panel stops at 45°. If you try to open it forcibly, it may cause
damage. Please do not try to use this device higher than your face as it is dangerous.
Please do not damage this product or the AC adaptor. It may cause an accident or other problems.
Please do not place items on the product or panel.
When unplugging the adapter, be sure to hold the adapter body and unplug it without pulling
the cable.
Please do not place the device in the following locations.
●Exposed to sunlight ●Wet environments ●Dusty environments ●Ignite environments ●Rain
and wind environments ●High temperature and below zero temperature environments ●Area
that generates chemical and gas ●High vibration environment
※Please keep this warranty in an accessible place for easy reference.
※Misuse and incorrect storage of this product are not covered by the warranty, and repair is subject to charge even during
the warranty period.
prohibit
prohibit
unplug the
adaptor
no
disassembling
water prohibit
wet hand
prohibit
strict
observe
strict
observe

3
1Contents of Package
This package includes the following contents.
Before using, be sure to check contents.
2Name of parts
■Contents
Exidéal mini beauty machine
Exidéal mini dedicated adaptor
5
2
1
LED Irradiation
Panel
Control Panel
AC Adaptor
Connector
1
1
2
2
LED Circle (5 LED inside)
Mirror Panel
【LED Irradiation Panel Names】
1
2
LED Irradiation
Back Panel

4
【Power】Button
Press the button to start with an electronic sound.
All operations are ready.
button can end any ongoing operations.
【MODE】Button
MODE button switches program and time select.
【SELECT】Button
SELECT button selects program and time.
(
1
)
Press the SELECT button to choose the program number between P1 to P4. Click to show P1 to P4→ P1 in order.
(
2
)
Press the MODE button to switch to time select.
Click to show 5 to 30 → 5 in order by every 1 minute.
(
3
)
Press the SELECT button can pause and restart irradiation program.
【
Display Monitor
】
(1)Program:【P】displays on the left,【Number】displays on the right.(Ex: P1)
(
2
)
Time:
【
Number
】
displays on the right. (Ex: 5 means 5 minutes)
(3)Ongoing irradiation program: It alternately switches program number and the time remaining (by 1 min).
【
START
】
Button
(1)Press the button to start program after selecting irradiation program.
(2)Press the button to stop program during irradiation.
3 Control Panel
●AC:100-240V
●50/60Hz
●12V 1A
●46.5×33.9×24.5mm
4 Exidéal mini AC Dedicated Adaptor