03/17 Model 1107L/1107LBP Page 2 of 4
RECOMMENDED TOOLS: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable
wrench, 10" pipe wrench, 5/64“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open end
wrench.
LOCATION OF UNIT: The Model 1107L/1107LBP Drinking Fountain is a wheelchair
accessible drinking water facility. The height dimensions shown, meet current ADA
requirements. When installing this unit, local, state or federal codes should be adhered to. If
height other than shown is required, then dimensions must be adjusted accordingly.
SUPPLY LINE: The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM)
pressure. Where sediment or mineral content is a problem, an inlet filter is recommended.
PLUMBING CONNECTIONS: Inlet is 3/8“O.D. push-in type fitting. Waste outlet is female
1-1/4” IPS.
MAINTENANCE: Periodically clean the strainer. Refer to 5874 Series Valve Manual for more
information.
INSTALLATION PROCEDURE
GENERAL NOTES:
1. For all plastic push-in type fitting connections, only connect NSF-61 copper or
plastic tubing. Stainless steel or glass tubing is not recommended. The
following assembly instructions must be followed to ensure a watertight
connection:
a. Cut tubing square and clean.
b. Mark from end of tube the length of insertion (See table below).
c. Push tube into the fitting until it bottoms out.
d. To remove, depress collet and pull tubing out.
Tube Sizes
Tolerance Insertion Depth
1. Insufficient bubbler flow. 1a. Check that inlet screwdriver stop valve is
wide open. (Customer supplied). Turn
b. Verify minimum 30 psi flowing supply
c. Clean strainer. See 5874 Series Valve
d. Adjust valve to increase flow. Use front
adjust screw or see 5874 Series Valve
For more information about Haws products, see our website: www.hawsco.com
© 2017 Haws®Corporation – All Rights Reserved
HAWS® and other trademarks usedin these materials are the exclusive property of Haws Corporation.