Hellermann Tyton TDDGT User manual

TDDGT - Instruction Manual
7-Day Digital Geyser Timer (Internal Relay)
Operating Instructions
Apply 220V to Live (L) terminal and Neutral (N) terminal
on timer.
Push Clock button once. Program 1 is now set.
Wait for 20 seconds, then push recessed Reset button.
Timer will reset.
For timer to operate automatically press Manual button
until On Auto appears on screen.
To operate timer manually press Manual button until On
or Off appears on screen.
SETTING DAY & TIME
Push and hold Clock button.
RECOMMENDED MUNICIPAL TIME SETTINGS
Push D+ repeatedly to adjust Day.
Timer 1: 04:00 ON –06:00 OFF
Push H+ repeatedly to adjust Hour.
Timer 2: 11:00 ON –14:00 OFF
Push M+ to adjust Minute.
Timer 3: 16:00 ON –18:00 OFF
Release Clock button. Time and Date set.
Timer 4: 21:00 ON –23:00 OFF
OR
RECOMMENDED POWER UTILITIES TIMES
21:00 ON –06:00 OFF
PROGRAMMING TIMER
WIRING
Push P button once (Program 1 On appears.)
Connect 220V to Live (L) terminal and Neutral (N) terminal
on timer.
‐Push D+ repeatedly until desired day is reached (various
combinations of days are available).
The Load must be connected to the Load terminal.
‐Push H+ repeatedly until desired hour is reached.
The Load terminal will be LIVE only when timer is on.
‐Push M+ repeatedly until desired minute is reached.
The Neutral of the Load must be connected to the
appropriate Neutral bar and NOT the timer.
Push P button once again (Program 1 Off appears).
‐Push D+ repeatedly until desired day is reached (various
combinations of days are available).
‐Push H+ repeatedly until desired hour is reached.
‐Push M+ repeatedly until desired minute is reached.
WIRING DIAGRAM
Line In Neutral
Live In
Geyser
Circuit
Breaker
Live
Load Out
Rated Voltage: 220-240V AC
Max 20A (3500 Watts)
16 Programmable Settings
Resistive Load (Geyser)
15-Day Backup Battery
Max 10A (Inductive Load)
IEC 60730 Rated
DIN Rail Mounted
Please note:
All electrical installations should be done by a qualified electrician.
The maximum current rating is 20 Amps.
Resistive loads (geysers, under-floor heating and lights)
Inductive loads (pool pump, air-conditioners).
TDDGT
Timer
[email protected]

Popular Timer manuals by other brands

Grasslin Digi 20A operating instructions

Grasslin

Grasslin Digi 20A operating instructions

DROPPY IT3828-16 user manual

DROPPY

DROPPY IT3828-16 user manual

ELPRO ELTIS-WEEK operating manual

ELPRO

ELPRO ELTIS-WEEK operating manual

Vimar Idea 16582 Series Installer manual

Vimar

Vimar Idea 16582 Series Installer manual

Goobay 55455 user manual

Goobay

Goobay 55455 user manual

Oregon Scientific TR112 user manual

Oregon Scientific

Oregon Scientific TR112 user manual

Tekmar Timer 031 Data brochure

Tekmar

Tekmar Timer 031 Data brochure

Daikin DST301B61 Operation manual

Daikin

Daikin DST301B61 Operation manual

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

GIC

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

Gewiss 90 AM Series manual

Gewiss

Gewiss 90 AM Series manual

GSC 000400269 manual

GSC

GSC 000400269 manual

Clas Ohlson 36-5391 quick start guide

Clas Ohlson

Clas Ohlson 36-5391 quick start guide

merten merten MEG5755-04 series manual

merten

merten merten MEG5755-04 series manual

Perry Electric ASTRO-LUX-TIME Instructions for installation and use

Perry Electric

Perry Electric ASTRO-LUX-TIME Instructions for installation and use

NuTone CD60W quick start guide

NuTone

NuTone CD60W quick start guide

ENDA ETM1411 quick start guide

ENDA

ENDA ETM1411 quick start guide

Melnor HydroLogic 53280 User instructions

Melnor

Melnor HydroLogic 53280 User instructions

Electrovision E304CF user manual

Electrovision

Electrovision E304CF user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.