manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HEPER
  6. •
  7. Control Unit
  8. •
  9. HEPER D-LIGHT AFX 1 Installation and operating instructions

HEPER D-LIGHT AFX 1 Installation and operating instructions

This manual suits for next models

1

Other HEPER Control Unit manuals

HEPER D-LIGHT AFX 4 Installation and operating instructions

HEPER

HEPER D-LIGHT AFX 4 Installation and operating instructions

HEPER D-LIGHT AFX 5 Installation and operating instructions

HEPER

HEPER D-LIGHT AFX 5 Installation and operating instructions

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1/3 2022-2 / 27/10/2022
Installation & Maintenance
Instructions
HEPER USA LLC
W227 N546 Westmound Drive Waukesha, 53186
Wisconsin, United States
+1 312 910 9740
[email protected]
D-LIGHT AFX 1 Module (LL2023.861-US)
13.42 lbs
https://heperlighting.com/us/ll2023.861-us/
2/3
3/3
English ( USA )
Safety
- The product must be installed in accordance with applicable
NEC standards by a qualified electrician familiar with the
installation of exterior lighting fixtures.
- The product must be operated under specified voltage at all
times.
- Do not install if parts are damaged.
- Power must be disconnected while installing or servicing to
avoid electrical shock.
- Failing to comply with warnings and installation steps in this
document might void warranty.
- Do not touch the light source.
- Make sure that temperature of the product is at a safe level before
touching.
- Do not allow cables to touch sharp edges of metal parts or other sharp
objects to avoid damage or abrasion.
- Check all of the cable connections including grounding before
powering the product.
- Check the proper grounding of the metal housing before powering the
product.
- Only use the product for its intended purposes.
- Do not use accessories not approved or recommended by
HEPER.
- Replace any broken/cracked protective surface with a new
one
- The external flexible cable or cord of this LED Module cannot be
replaced; if the cord is damaged, the module shall be destroyed.
- The light source of this LED Module is not replaceable; when the light
source reaches its end of life the whole Module shall be replaced.
- Ethr value of the module according to IEC TR 62778 Standard: 1280 lx
- The LED Module should be positioned so that prolonged staring into
one LED Module at a distance closer than 1,3 m is not expected.
- The maximum working voltage of basic insulation between the active
parts of the LED module and external metallic parts: 260 V.
Installation
- Make the connection of the spigot. (Spigot position may change
according to project needs)
- Secure the pole to the spigot as shown on the visual.
Replacement of the light source
- Disconnect the power coming into the product.
- Detach the AreaFlex (AFX) module as shown on the visual.
- Reinstall the product following the same steps.
Replacement of the control gear
- Unlock the clip to reach the driver location.
- The electrical connection automatically will be blocked when the cap is
opened. Make sure that the mechanism is locked which is on the side of
the cap.
- Detach the driver as shown on the visual.
Cleaning - Maintenance
- The product was designed and manufactured to operate for a long
period of time. To ensure maximum lifespan of the product, regular (i.e.
every six months) visual inspection and cleaning with a solvent-free
cleaner using a soft cloth is recommended.
- Do not clean or service while the product is power connected.
Disposal
- In accordance with EU Directive WEEE (Waste Electrical and
Electronic Equipment), luminaires must not be disposed of with
other household waste. At the end of their life, luminaires must
be taken to the appropriate local facility available for the
disposal or recycling of electronic products.
Wiring Color Codes
- Ground - GREEN
- Line - BLACK
- Neutral - WHITE
- Dim(+) - RED/PURPLE
- Dim (-) - GRAY/ORANGE