1/3 2022-2 / 27/10/2022
Installation & Maintenance
Instructions
HEPER USA LLC
W227 N546 Westmound Drive Waukesha, 53186
Wisconsin, United States
+1 312 910 9740
[email protected]
D-LIGHT AFX 4 Module (LL2023.864-US)
21.47 lbs
https://heperlighting.com/us/ll2023.864-us/
2/3
3/3
English ( USA )
Safety
- The product must be installed in accordance with applicable
NEC standards by a qualified electrician familiar with the
installation of exterior lighting fixtures.
- The product must be operated under specified voltage at all
times.
- Do not install if parts are damaged.
- Power must be disconnected while installing or servicing to
avoid electrical shock.
- Failing to comply with warnings and installation steps in this
document might void warranty.
- Do not touch the light source.
- Make sure that temperature of the product is at a safe level before
touching.
- Do not allow cables to touch sharp edges of metal parts or other sharp
objects to avoid damage or abrasion.
- Check all of the cable connections including grounding before
powering the product.
- Check the proper grounding of the metal housing before powering the
product.
- Only use the product for its intended purposes.
- Do not use accessories not approved or recommended by
HEPER.
- Replace any broken/cracked protective surface with a new
one
- The external flexible cable or cord of this LED Module cannot be
replaced; if the cord is damaged, the module shall be destroyed.
- The light source of this LED Module is not replaceable; when the light
source reaches its end of life the whole Module shall be replaced.
- Ethr value of the module according to IEC TR 62778 Standard: 1280 lx
- The LED Module should be positioned so that prolonged staring into
one LED Module at a distance closer than 1,3 m is not expected.
- The maximum working voltage of basic insulation between the active
parts of the LED module and external metallic parts: 260 V.
Installation
- Make the connection of the spigot. (Spigot position may change
according to project needs)
- Secure the pole to the spigot as shown on the visual.
Replacement of the light source
- Disconnect the power coming into the product.
- Detach the AreaFlex (AFX) module as shown on the visual.
- Reinstall the product following the same steps.
Replacement of the control gear
- Unlock the clip to reach the driver location.
- The electrical connection automatically will be blocked when the cap is
opened. Make sure that the mechanism is locked which is on the side of
the cap.
- Detach the driver as shown on the visual.
Cleaning - Maintenance
- The product was designed and manufactured to operate for a long
period of time. To ensure maximum lifespan of the product, regular (i.e.
every six months) visual inspection and cleaning with a solvent-free
cleaner using a soft cloth is recommended.
- Do not clean or service while the product is power connected.
Disposal
- In accordance with EU Directive WEEE (Waste Electrical and
Electronic Equipment), luminaires must not be disposed of with
other household waste. At the end of their life, luminaires must
be taken to the appropriate local facility available for the
disposal or recycling of electronic products.
Wiring Color Codes
- Ground - GREEN
- Line - BLACK
- Neutral - WHITE
- Dim(+) - RED/PURPLE
- Dim (-) - GRAY/ORANGE
Disclaimer
- HEPER reserve the right to make technical and design changes.

This manual suits for next models

1

Other HEPER Control Unit manuals

HEPER D-LIGHT AFX 1 Installation and operating instructions

HEPER

HEPER D-LIGHT AFX 1 Installation and operating instructions

HEPER D-LIGHT AFX 5 Installation and operating instructions

HEPER

HEPER D-LIGHT AFX 5 Installation and operating instructions

Popular Control Unit manuals by other brands

Barco Hydra Brochure & specs

Barco

Barco Hydra Brochure & specs

phytron phyMOTION INAM01.1 TRANSLATION OF THE GERMAN ORIGINAL MANUAL

phytron

phytron phyMOTION INAM01.1 TRANSLATION OF THE GERMAN ORIGINAL MANUAL

KSB BOAX- B operating instructions

KSB

KSB BOAX- B operating instructions

AMC AMC-1228 instructions

AMC

AMC AMC-1228 instructions

ABB RTU500 series user manual

ABB

ABB RTU500 series user manual

Suttle SOHO Access SAM-V8 installation instructions

Suttle

Suttle SOHO Access SAM-V8 installation instructions

Eaton Vickers CM2 Series Overhaul manual

Eaton

Eaton Vickers CM2 Series Overhaul manual

IFM Electronic efector 600 TR2432 operating instructions

IFM Electronic

IFM Electronic efector 600 TR2432 operating instructions

Moxa Technologies ioMirror E3200 Series Quick installation guide

Moxa Technologies

Moxa Technologies ioMirror E3200 Series Quick installation guide

Panasonic CF-BAH0256U operating instructions

Panasonic

Panasonic CF-BAH0256U operating instructions

Panasonic CATU9000U - AV CTRL AMP operating instructions

Panasonic

Panasonic CATU9000U - AV CTRL AMP operating instructions

National Instruments NI DCM-2316 Getting started guide

National Instruments

National Instruments NI DCM-2316 Getting started guide

Moeller S40-AM-TD manual

Moeller

Moeller S40-AM-TD manual

rtd CM17407HR user manual

rtd

rtd CM17407HR user manual

Danfoss MNF Series operating guide

Danfoss

Danfoss MNF Series operating guide

Siemens 3VL9800-3MJ00 operating instructions

Siemens

Siemens 3VL9800-3MJ00 operating instructions

evertz 7700 Series manual

evertz

evertz 7700 Series manual

Advantech SOM-5962 user manual

Advantech

Advantech SOM-5962 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.