Hiltron security XM19C User manual

1
XM19C -Tastiera corazzata per centrali antifurto Serie XM
XM19C
XM19T
XM19T-Tastiera per centrali antifurto Serie XM ad incasso per Serie Living International
Blu : MPX
Rosso : +12V EXT
Giallo : RS485A
Verde : RS485B
IN
OUT
IN
OUT
Bianco
Arancio
Centrale
Serie XM
GND MPX A B
+12
EXT Consolle
Nero : GND
TAMPERA B OUT
IN
Nero
Rosso
Giallo
Verde
XM19T
!Tamper di protezione antistrappo
(Solo XM19C)
!Buzzer
!LED di segnalazione
Ingressi programmabili 1
Tastiera numerica 12 tasti
Tensione nominale di alimentazione 12Vcc ±5%
Assorbimento massimo 40mA 25mA
Grado protezione del contenitore IP54
Uscita a collettore aperto 30mA
Contenitore esterno allum. verniciato in polvere epossidica
Grado di sicurezza 1
Classe ambientale 2
Dimensioni (L)x(A)x(P) 110x75x20mm 70x100x21mm
Dimensioni 3 mod.della Serie Living International®
XM19T XM19C
XM19C
Pb
Lead free
RoHS
compliant
Pb
Lead free
RoHS
compliant
Pb
Lead free
RoHS
compliant
Pb
Lead free
RoHS
compliant
RAEE
security
Made in Italy
BT2014/35/UE
EMC2014/30/UE

2
XM19C -Tastiera corazzata per centrali antifurto Serie XM
XM19T-Tastiera per centrali antifurto Serie XM ad incasso per Serie Living International
PROGRAMMAZIONE ID CONSOLLE
Di default la consolle ID001 è già abilitata in centrale, per cui è sufficiente collegare la prima consolle con
ID di default.
Per installare più consolle sulla linea multiplexer è necessario assegnare ID differenti (fino a 8 ID). Per
cambiare l'ID della consolle:
!dare tensione alla consolle, senza collegare la RS485 (A e B)
!il LED Blu ed il LED Verde lampeggiano rapidamente, a segnalare “Errore Link”
!per modificare l’ID premere 4 volte entro 30 secondi
!viene visualizzato l’ID corrente, e viene segnalato anche mediante i lampeggi del LED Blu, ad intervalli di
circa 2 secondi
!utilizzare i tasti da 1 a 8 per scegliere l'ID
!premere per confermare
!staccare la tensione, e ricollegare la RS485
NOTA: il cambio dell'ID è sempre possibile solo se la consolle non risulta connessa alla linea RS485
NOTA: di default le consolle sono programmate con l’ ID 001.
NOTA: per uscire dalla programmazione senza apportare modifiche premere il tasto
Se viene cambiato ID, e questo non è abilitato in centrale. il LED Blu lampeggia rapidamente, e
l’ID viene segnalato mediante i lampeggi del LED Verde, ad intervalli di circa 2 secondi.
FUNZIONAMENTO
(inserire / disinserire l’impianto nel modo corrente).
(inserire nel modo corrente).
(disinserire l’impianto).
E’ inoltre possibile cambiare il modo di inserimento dell’impianto, direttamente dalla tastiera:
IMPORTANTE : Fare attenzione alla segnalazione del LED Blu :
(può accadere che in un cambio di modo (es. da modo Parziale a modoTotale) il led
segnalerà le eventuali Zone Aperte per cui non sarà possibile inserire l’impianto.
Bisognerà chiudere le eventuali zone aperte e successivamente inserire l’impianto
secondo la procedura descritta precedentemente.
#
9
1
7
9
MODO
1
CODICE
#
CODICE
#
CODICE
#
CODICE #
9
0
Funzionamento Display
Tenendo premuto per più di 3 secondi il tasto sulla tastiera, si ottiene:
!lo spegnimento della retroilluminazione del display
!la disabilitazione del buzzer
!lo spegnimento dei LED di segnalazione di stato
Tenendo premuto per più di 3 secondi il tasto sulla tastiera, si ottiene:
!lo spegnimento della retroilluminazione del display
!la disabilitazione del buzzer
In ogni caso, premendo un qualsiasi tasto della consolle la retroilluminazione del display e i led di
segnalazione si riaccendono per circa 30 secondi, per poi ritornare alla funzione programmata.
Per riportare la consolle al funzionamento iniziale, è necessario premere il tasto per più di 3 secondi.
security

1
XM19C -Armored keypad for burglar central unit XM Series
XM19C
XM19T
XM19T-Embedding keypad XM for XM Series
Blue : MPX
Red : +12V EXT
Yellow : RS485A
Green : RS485B
IN
OUT
IN
OUT
White
Orange
Serie XM
burglar central unit
GND MPX A B
+12
EXT Consolle
Black : GND
TAMPERA B OUT
IN
Black
Red
Yellow
Green
XM19T XM19C
Programmable inputs 1
Numerical keypad 12 keys
Power supply voltage 12Vdc ±5%
Max current consumption 40mA 25mA
Box protection level IP54
Uscita a collettore aperto 30mA
External box epoxidic dust painted aluminum
Safety degree 1
Ambiental class 2
Dimensions (W)x(H)x(D) 110x75x20mm 70x100x21mm
Dimensions 3 modules of Living International®
!Antitearing protection tamper
(only XM19C)
!Buzzer
!Signalling LED
XM19T XM19C
Pb
Lead free
RoHS
compliant
Pb
Lead free
RoHS
compliant
Pb
Lead free
RoHS
compliant
Pb
Lead free
RoHS
compliant
RAEE
security
Made in Italy
BT2014/35/UE
EMC2014/30/UE

2
ID CONSOLLE PROGRAMMATION
By default, the console is already enabled in ID001 Central, so simply connect the first Console ID by
default. If ID is changed, and this is not enabled in central unit.
The blue LED flashes rapidly, and the ID is indicated by the Green LED blinks at intervals of
approximately 2 seconds.
To install multiple consoles on line multiplexers you must assign different ID (up to 8 ID). To change the ID
of the console:
!give power to the console, with NO connect the RS485 (Aand B)
!the blue LED and the Green LED is flashing rapidly, indicating "Link Error"
!for modify ID press 4 times the button within 30 seconds
!current ID appears, and is indicated by the LED flashes Blue, at intervals of approximately 2 seconds
!utilize the buttons from 1 at 8 for choose the ID
!press for confirm
!Unplug the power and riconnect the RS485
NOTE: the change of ID is always possible only if the console is not connected to the RS485 line
NOTE: of the default console are programmed with ID 001.
NOTE: for exit programming without making any changes, press the button
OPERATION
(enabled / disabled the system in current mode).
(enabled in current mode).
(disabled the system).
It is also possible to change the mode of enabled directly from the keyboard:
ATTENTION : Attention to the Blue LED signal:
(it’s possible that in a change of mode (example. from PARTIAL MODE at TOTAL MODE) the
led report any open areas so you will not be able to enter the plant.
You must close any open areas and subsequently enter the facility in accordance with the
procedure described above.
#
9
1
7
9
MODO
1
CODICE
#
CODICE
#
CODICE
#
CODICE #
9
0
Display Operation
Press and hold for more than 3 seconds the button on the keyboard, you get:
!turn off the backlight on the display panel
!The buzzer disabled
!OFF of the status LEDs
Press and hold for more than 3 seconds the button on the keyboard, you get::
!turn off the backlight on the display panel
!The buzzer disabled
In any case, if you press any key on the console and display backlight LEDs will turn on for about 30
seconds, then return to the scheduled function.
To restore the initial operating console, you must press the button for more than 3 seconds.
XM19C -Armored keypad for burglar central unit XM Series
XM19T-Embedding keypad XM for XM Series security
466ADIE-2.03
This manual suits for next models
1
Table of contents
Languages:
Popular Keypad manuals by other brands

SEW-Eurodrive
SEW-Eurodrive MOVITRAC B operating instructions

LEGRAND
LEGRAND AU7050 installation instructions

Overhead door
Overhead door ALLSTAR quick start guide

Visonic
Visonic MKP-150 user guide

GE
GE NX-148E-RF - Security NetworX NX-8E System installation instructions

Tyco
Tyco DSC WK250 Installer's guide