(The QLO does not work.)
I
• Do not insert anything like slender stick
into the discharge air plenum or return air
grille as the fan is running at high speed,
it is highly likely to cause danger.
When thunder is likely to happen, for
protecting the machine, stop operation
and turn off the power switch to prevent
from failure.
❹Press the button. Cooling operation starts with a beep. Press the button again to stop operation. The
cooling function does not start if the temperature setting is higher than the current room temperature (even
though the “RUNNING” (OPERATION) lamp Iights). The cooling function will start as soon as you set the
temperature below the current room temperature.
DEHUMIDIFYING OPERATION
Usethedevicefordehumidifyingwhentheroomtemperatureisabove16°C.
When it is under 15°C, the dehumidifying function will not work.
• When the window and the door are open (the humidity inside the room continuously exceeds 80%), the air
vanes of the louver are facing down or in the auto-swing mode, do not operate the machine for too long as it
is likely that humid air may condensate on the louver and may drip down water and wet the furniture.
• If there is a heat source (many people come in and out, a heating appliance is being used, etc.) that exceeds the
capacity of cooling or heating, the room temperature may not reach the desired setting level.
• If there is any abnormal noise is heard during unit operation, refer to the service center or to the dealer from
where the air conditioner was purchased.
• When installing at areas subjected to high salinity, sulfur, corrosive substance such as coastal areas and
hot springs, the heat exchanger of the unit or the circulation piping must be treated with anti-corrosion
coating.Inaddition, installation atplaces subjectedtoplentyoffumes,at hospitalswhereelectromagnetic
wave is available, atplacessubjecttodustanddirtorspecialenvironmental situations aroundinstallation,
consult the service center or the dealer from where the air conditioner was purchased first.
•
C
A
u
T
N
•
Whileindoorunitfrontcoverisnot installed,donotoperatetheunit.Moreover, besuretotakegoodmeasures
against
dust and dirt for unitbody.
•Beforetheunitstarts,besuretocheck thatthe roomhasbeencleaned up,airbornemattersandodors have
been cleared, the unit body isclean. This willprevent insufficient cooling or waterleakage inlater days.
• Plug the power cord to the right source, and the voltage required by the air conditioner is 230V.
• If the power of the air conditioner is connected to an incorrect voltage, it will invariably burn out the electrical
parts.
•Besuretofirmly plugthe powersupply cordoritmaycause short circuit orheat resulting indanger offireor
electric shock.
• Periodically check the power cord plug and receptacle every year to ensure that they are clean.
•Wheninstallingthewater drain hose, besurewatercanflowoutsmoothly. Ifinstallationisnotproper, itis
possible that water may flow inside the room or get your furniture wet.
• This unitisintended tobeusedfor general family room airconditioning purpose, donot useitforstoringfood,
animals and plants, precision machinery, fine art works, medicine, etc.
•
The outdoor side should be well ventilated. Do not place any obstacle near the air discharge outlet, otherwise,
the unit performance may decrease and the noise increases.
• Do not place any object in front of the indoor side, otherwise, it may affect airflow and Impede operation of the
unit.
• Do not place any foreign material around the unit body, otherwise, it may affect the performance of the unit.
• Do not allow ejected heated air to face your neighbors. Also, do not let water dripping, drainage, vibration,
noise, etc. interfere your neighbors.
• Do not install at places where flammable objects and flammable gases exist.
If such objects and gases are around, a fire mayoccur.
e When installing near places with high humidity such as bathing facilities, damp and humid places, basements,
and places with frequent water accumulation, be sure to install an earth leakage circuit breaker to prevent
current leakage. Consult the dealers (a registered water and electrical engineering dealer) for details.
• To avoid carelessness from power companies or other accidents that cause over current to get into the unit via
the ground wire resulting in damage to the unit, be sure to install an earth leakage circuit breaker. Consult the
dealers (a registered water and electrical engineering dealer) for details. If no earth leakage circuit breaker is
installed, there is a risk of accident such as electric shock to occur.
• To avoid electric shock in case of current leakage, be sure to connect the air conditioner to the
ground. The ground wire diameter should be 2.5 mm² to 6 mm². Also, the end of the ground wire
must be crimped with a round terminal before securing it and must not be loose by accident.
Do not connect the ground wire to the gas pipe, water pipe, lightning rod, and the telephone line.
If the ground wire is not installed properly, there is a risk of electric shock. If the unit is not grounded,
the protective circuit such as lightning striking protection will not work properly.
C
A
U
T
I
0
N
UNIT DISPLAY
INDICATION DISPLAY ON THE FRONT COVER
FAN SPEED indicator light
•When the unit is running, the light turnson.
•When you press this button, the intensity of circulation
will change from (AUTO) to (HI) to (ME) to (LO)incycle.
POWERFUL indicator light
•Use these buttons to start powerful operation.
Whenthe uni
t is performing a powerful operation, this
light turns on.
Room temperature display
When the unit is powered up, the computer will
automatically detect the room temperature and
display the current temperature.
(Indicatestheerrorcodewhenanerroroccurs)
AUTO SWING indicator light
When you press the button, the vertical louver will
automatically be swinging.
TIMER indicator light
When the unit is preset with a timer, this light turns on.
Infrared light receiving window
A “beep” sound will be generated when it receives the
signal from the remote controller.
REMOTE CONTROLLER
MODE indicator Iight
When the unit is running, the light turns on.
When you press this button, the mode will change
, from (COOL) to (FAN) to (DRY) incycle.
ON/OFF button
Press this button to start operation, press it again
to stop operation.
RA-06HSVC
• Use only on single outlet circuit exclusive for the air conditioner.
• Ensure the mounting support is firm and steady or there is a risk the unit may fall.
Johnson Controls-Hitachi Air Conditioning Philippines, Inc.
1A Binictican Drive, Subic Bay Industrial Park Phase II Subic Bay Freeport Zone, Philippines
TEL: (02)362-4847
TEL(SERVICE): (02)362-3842
W
A
R
N
I
N
• Read this section of “Safety precaution” carefully to understand proper usage of this unit before use.
• Pay special attentions to “ Warning” and “ Caution” designations contained in this manual. The “ Warning"
designation may cause death a serious of injury if not followed correctly. Failure to follow the instructions under the
“ Caution” designation may also cause possible serious consequence depending on the situation. Therefore, be
sure to observe these designations for your safety.
•In addition, this sign “”shown in the diagram denotes prohibited items, whereas “”denotes mandatory items.
• Be sure to keep this manual after reading.
• The manufacturer is not liable for maintenance and repair of the air conditioner as stipulated in the warranty. The
same condition applies to any damage to this unit body/nearby property if you fail to observe warning instructions in
this manual/use of parts not supplied from us.
•This product uses non-flammable R410A refrigerant. While the product is under installation or transport, except R410A
refrigerant, please do not charge other refrigerants, air, oxygen, propane, alcohol, or any flammable material to avoid
machine damage, blaze, or explosion. Be sure to use the refrigerant specified by the manufacturer.
• If there is an error (burning odor, etc.), stop operation and turn off the power switch and then notify the
service center or the dealer from where the air conditioner was purchased. If the air conditioner keeps on
running with the error, it may lead to failure, electric shock, fire, etc.
• To service the air conditioner, directly contact the service center or the dealer from where the air conditioner
was purchased. If it is improperly repaired by yourself, there is a risk of electric shock or fire.
• If the air conditioner is to be moved or relocated, directly contact the service center or the dealer from where
the air conditioner was purchased. If it is moved or relocated improperly by yourself, there is a risk of electric
shock or fire.
• If the power cord is damaged, it must be replaced by the manufacturer or by the service
center or a technician to prevent danger
Operation manual
Window Inverter Type
Room Air Conditioner
• Air conditioner installation and its electrical wiring require a professional. Therefore, assign
only an authorized dealer or a certified technician to install your air conditioner and perform
its electrical wiring. Do not attempt to do it by yourself (charges are additional). If improperly
performed by yourself, it may cause leakage, electric shock or fire.
• Do not use a metal wire or copper wire as a fuse to prevent from failure or fire.
W
A
R
N
I
N
G
•When installing, do not use an extended power cord or a power cord with excess bending
(radius less than 20mm). Also, use the cable tie supplied with the base-pan to secure it. Do not place the
cord inside the unit body or it may cause short circuit or abnormal heat leading to a fire due to insulation
damage by an overly compressed cord.
C
A
U
T
I
O
N
•
Temperature button
Press this button to raise or lower the temperature.
•
•When cleaning the unit body, never wash
it with splashing water as there is a risk
of current leakage.
• Do not let the discharge air plenum
directly face your body for a long
period of time, or it may have
adverse effect to health.
W
A
R
N
I
N
G
C
A
U
T
I
O
N
• Do not operate the switch when your
hand is wet to prevent electric shock.
• If a gas stove is used while the air
conditioner is operating, be sure to
open the window often, or it is possible
to have insufficient oxygen inside.
• If the machine will not be used for a
long period of time, turn off the power
switch for safety.
• Do not place animals or plants at the place
to where the airflow is blowing directly, or
it will have adverse effect to them.
❶Press the button so that the display indicates "COOL".
❷Set the desired FAN SPEED with the button (the display indicates the
setting).
AUTO : The FAN SPEED is HI at first and varies to ME automatically when the preset
temperature has been reached.
❸Set the desired room temperature with the buttons. The temperature setting and
the actual room temperature may vary somewhat depending on conditions.
❶Press the button so that the display indicates “DRY” (DEHUMIDIFY).
The FAN SPEED is set at “LO” automatically.
❷Press the button.
COOLING OPERATION
Use the device for cooling when the outdoor temperature is above 10°C. If humidity is very high
(over 80%) indoors, some dew may form on the air outlet grille of the indoor unit.
※
Operating range of cooling: Indoor 21°C~32°C, Outdoor 10°C~42°C
21°C -32°C ' outdoor 10°C -46°C.
SAFETY PRECAUTIONS
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
FUNCTIONS LIST AND FEATURES
USAGE PRECAUTIONS
INSTALLATION PRECAUTIONS
• Do not let the airflow directly face the
gas stove, or it is likely to cause
incomplete combustion.
•When cleaning the unit body, be sure to turn
off the power switch, or it may cause injury
as the fan is running at high speed inside.
RA-10HSVC
IMPORTANT:
READ AND UNDERSTAND THIS
MANUAL BEFORE USING THIS
AIR CONDITIONER.
KEEP THIS MANUAL FOR
FUTURE REFERENCE.
RA-08HSVC
When the air conditioner will not be used for a Iong period of time, turn on the “Strong fan speed” on a clear day and
run the unit for haIf a day so that the inside of the unit can be dried.
After the inside of the air conditioner is dried, unplug the power cord or disengage the knife switch or the circuit
breaker exclusively set up for the air conditioner for safety.
Use the screws supplied together with the unit to secure the front cover.
Before pulling out the unit body, first remove the screws and the parts for fixation.
NOTICE
NOTICE
LOCK SETTING
After the lock setting is done, you can only use the button and the
button to change mode, the others are invalid.
(TEMP.)
POWERFUL OPERATION
During the operation (DEHUMDIFYING, COOLING),
you should press the button to start the powerful operation
•
HOW TO SET THE TIMER
❷When the machine runs-on, press button.
▪
You can set the time to stop.
▪
Press continuously to get rapid adjustment.
▪
If you want to stop the machine right away, youcanpress button to cancel all reservation of timesetting.
HOW TO SET THE SLEEP TIMER
This function will change the fan speed and the room temperature setting automatically
during sleep and you also can use the OFF-TIMER function together too.
You can set the time in 1 to 24 hours for sleep mode.
HOW TO ASSEMBLE THE INSTALLATION BRACKET
It is easy for the front cover and the cabinet to get dirty. Wipe it regularly with dry cloth. If it is dirty, use a wet and
soft cloth to wipe.
When the air conditioner starts to operate, it may possibly blow out dusts. This is because there are dusts
accumulating on the discharge air plenum.
NOTICE :
Do not wash the front cover with water over 50°C to prevent it deformation.
To prevent the front cover from damage, never wash it with volatile oil, gasoline,
thinner, grinding powder or a chemical abrasive cloth.
To avoid poor insulation and current leakage, never wash the air conditioner
directly with water.
2. These are all normal indications:
WIRING DIAGRAM
❶Choose the operating mode, fan speed and setting temperature you want.
❷In the power off state, press and hold the button first and press the lower
location of (TEMP.) button later.
(Meanwhile, the mark will be displayed on the remote controller.)
CANCEL: Repeat the ❷procedure above to cancel the lock setting.
❶Press the button to start the powerful operation.
Every time you press the button, it will increase the fan speed. If the
original fan speed is "Hi", the fan speed will not change.
CANCEL: Press the button again
CONTENT OF THE POWERFUL OPERATION
The timer may be used in two ways: (OFF-TIMER), (ON-TIMER). You can set only one kind of
timer. You can set the time in 1 to 24 hours for timer mode.
❶When the machine runs-off, press the button.
▪You can set the time of running.
▪Press continuously to get rapid adjustment.
▪If you want to start the machine right away, you can press button to cancel all
reservation of time setting.
❶Press button. Display indicates
▪Press continuously to get rapid adjustment.
▪The SLEEP operation starts at beep sound, then the remote controller display will
show the reservation time and turn-off time.
CANCEL: Press the button to cancel.
Before cleaning, turn off the air conditioner first and unplug the power cord.
(Never unplug the cord with a wet hand to prevent electric shock.)
▪If the air conditioner does not resume standard operation after checking any of the above items, please notify
the service center or the dealer where the air conditioner is purchased of the malfunction together with the air
conditioner model, manufacture number, and installation date recorded on the warranty.
▪If the power cord/cord plug gets abnormally hot or the insulation sheath is stripped/melted, unplug the power
cord and immediately contact the service center and the dealer where the air conditioner is purchased. Do not
replace the power cord by yourself to prevent danger!
▪The timer indicator light on the display flashes and the display screen shows a number.
▪(The cause of the error can be determined by the number of flashes, and thus the problem can soon be
corrected. Therefore, before turning off the power switch, confirm the number of flashes and the displayed
number and then notify the service personnel.)
1. If an error is found, first check the following items.
65MP1440 RA-A3
SERVICE GUIDELINES
2. CLEANING THE FRONT COVER AND THE CABINET
3. HOW TO HANDLE THE AIR CONDITIONER AFTER THE USAGE SEASON IS OVER
AFTER-SALE SERVICE AND WARRANTY
HOW TO ASSEMBLE THE INSTALLATION BRACKET AND THE WATER DRAINAGE
INSTALLATION PRECAUTIONS
as the top priority to turn-on,
The other timer setting are all invalid.
HOW TO ASSEMBLE THE INSTALLATION BRACKET
OUTDOOR SIDE INSTALLATION DISTANCE
ACCESSORY NAMES AND QUANTITIES
▪Water drainage elbow X1
▪Caulking foam X1
▪Battery X2
▪Remote controller X1
USE OF IRON SUPPORT IS REQUIRED.
The iron support installed (field-supplied) should
be strong enough to support the air conditioning
unit and should be rigidly fixed to the wall.

This manual suits for next models

2

Other Hitachi Air Conditioner manuals

Hitachi RAK-65NH5 User manual

Hitachi

Hitachi RAK-65NH5 User manual

Hitachi RAS-D10CDK User manual

Hitachi

Hitachi RAS-D10CDK User manual

Hitachi airHome 400 User manual

Hitachi

Hitachi airHome 400 User manual

Hitachi RAC-70YHA1 User manual

Hitachi

Hitachi RAC-70YHA1 User manual

Hitachi RAS-S10HA User manual

Hitachi

Hitachi RAS-S10HA User manual

Hitachi RPIL-1.0PNN1DH Instruction Manual

Hitachi

Hitachi RPIL-1.0PNN1DH Instruction Manual

Hitachi RAC-AH10PCASM User manual

Hitachi

Hitachi RAC-AH10PCASM User manual

Hitachi RAK-15QEF User manual

Hitachi

Hitachi RAK-15QEF User manual

Hitachi RAS-P25YHAB User manual

Hitachi

Hitachi RAS-P25YHAB User manual

Hitachi airHome 600 User manual

Hitachi

Hitachi airHome 600 User manual

Hitachi RAF-25RXB User manual

Hitachi

Hitachi RAF-25RXB User manual

Hitachi RAS-72CHA3 User manual

Hitachi

Hitachi RAS-72CHA3 User manual

Hitachi RCI-1.0FSR1 User manual

Hitachi

Hitachi RCI-1.0FSR1 User manual

Hitachi RAS-07GH4 User manual

Hitachi

Hitachi RAS-07GH4 User manual

Hitachi RAF-25NXA1 User manual

Hitachi

Hitachi RAF-25NXA1 User manual

Hitachi RAM-130QH5 User manual

Hitachi

Hitachi RAM-130QH5 User manual

Hitachi UTOPIA RAS-4 Series User manual

Hitachi

Hitachi UTOPIA RAS-4 Series User manual

Hitachi RAC-18WED User manual

Hitachi

Hitachi RAC-18WED User manual

Hitachi airCore 700 Instruction Manual

Hitachi

Hitachi airCore 700 Instruction Manual

Hitachi UTOPIA R32 Series User manual

Hitachi

Hitachi UTOPIA R32 Series User manual

Hitachi RAC-VJ50PHAT User manual

Hitachi

Hitachi RAC-VJ50PHAT User manual

Hitachi RAS-X10CCK User manual

Hitachi

Hitachi RAS-X10CCK User manual

Hitachi RAS-S24H2A User manual

Hitachi

Hitachi RAS-S24H2A User manual

Hitachi RAS-X10CB User manual

Hitachi

Hitachi RAS-X10CB User manual

Popular Air Conditioner manuals by other brands

Daikin FTKE25BVM Service manual

Daikin

Daikin FTKE25BVM Service manual

Mitsubishi Electric PLA-M100EA installation manual

Mitsubishi Electric

Mitsubishi Electric PLA-M100EA installation manual

Dometic MCS T6 operating manual

Dometic

Dometic MCS T6 operating manual

Innova IGZCAPS NI Series owner's manual

Innova

Innova IGZCAPS NI Series owner's manual

EMI WLCA operation instruction

EMI

EMI WLCA operation instruction

Eberg QUBO Q40HD instruction manual

Eberg

Eberg QUBO Q40HD instruction manual

Mitsubishi Electric PLA-SP BA Series Operation manual

Mitsubishi Electric

Mitsubishi Electric PLA-SP BA Series Operation manual

ALPATEC AC 12 FIT user manual

ALPATEC

ALPATEC AC 12 FIT user manual

Daikin Comfort Flex CLIV Series Installation, operation and maintenance manual

Daikin

Daikin Comfort Flex CLIV Series Installation, operation and maintenance manual

Dimplex DCEVP5WG instruction manual

Dimplex

Dimplex DCEVP5WG instruction manual

Mitsubishi PQHY-P200YGM-A installation manual

Mitsubishi

Mitsubishi PQHY-P200YGM-A installation manual

Panasonic CS-LZ9ZKA operating instructions

Panasonic

Panasonic CS-LZ9ZKA operating instructions

Mitsubishi Electric Mr.Slim PEA-M200 installation manual

Mitsubishi Electric

Mitsubishi Electric Mr.Slim PEA-M200 installation manual

GE AEZ10AVL1 Owner's manual and installation instructions

GE

GE AEZ10AVL1 Owner's manual and installation instructions

Panasonic S-M20PY3E installation instructions

Panasonic

Panasonic S-M20PY3E installation instructions

REMKO SKT 521 Operating and installation instructions

REMKO

REMKO SKT 521 Operating and installation instructions

Daikin FXFQ07TVJU Operation manual

Daikin

Daikin FXFQ07TVJU Operation manual

LG LW1221IVSM owner's manual

LG

LG LW1221IVSM owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.