&
¥Toopenthefrontpanel, use the remote controller to stop unitoperation.Thenpress
thetwoÒ Ó sections below PUSH at the topleftandright corners of the front panel.
¥ Grasp the left and right sides of the front panel and open it toward you.
& &
¥Toclose the front panel, press the two Ò Ó sections below PUSH at the top left and
right corners of the front panel.
¥ Press the upper center part of the front panel to close properly.
"- # " ! #
&
This lamp lights when the timer is working.
# &
This lamp lights during operation.
During heating, the operation indicator may blink, blowing
very lightly or totally stopping under the following
conditions:
(1)
' (
For about 2~3 minutes after start up.
(2)
' (
Defrosting will be performed about once an hour when
frost forms on the heat exchanger of the outdoor unit,
for 5~10 minutes each time.(If the piping length used
is longer than usual, frost will likely to form.)
! &
This lamp lights when the device is operated
foratotal of about 100 hours, it is time to clean
the filter. The lamp goes out when the
Ò(AUTO SWING)Ó button is pressed while
the operation is stopped.
#. -"
-"
Upper center part
OOLING OPERATION
¥Ifcooling is started at an AUTO or HI fan speed
setting, and if a considerable difference is present
between the room temperature and preset
temperature, the damper inside of the bottom air
outlet will automatically open to allow cold air to
also be directed out of the bottom side air outlet.
When the room temperature reaches the preset temperature or after approximately 30 minutes have elapsed from
starting operation, cold air will automatically be directed only from the top side air outlet.
¥ When it is desirable to direct cold air from the bottom side air outlet for a longer period of time, set the temperature
at 16¡ and fan speed at HI. When the room temperature is more than 8¡ above the preset temperature (16¡ ),
cold air will continuously blow from the bottom side air outlet.
DEHUMIDIFYING OPERATION
¥ For more efficient dehumidifying, the bottom side air outlet will remain closed.
FAN OPERATION
¥ Air blows out only from top side air outlet.
AIR OUTLET SWIT H IS SET TO
¥ Air blows out only from top side air outlet in both heating and cooling operation.
¥ Air can be blown only from top side air outlet, to prevent blowing air striking your face during sleep, etc.
¥Ifair blows out only from the top side air outlet, it takes more time to reach the set temperature when compared to
air blowing from both top and bottom side air outlets. Also, temperature distribution within the room may be adversely
affected. It is therefore recommended to use both top and bottom side air outlets whenever possible.
#. -"
If the remote controller does not work due to battery failure,
press this switch to start and stop operation.
¥ This temporary operation will be at the most recent setting
made.(The unit will immediately go into automaticoperation
once power is switched on.)
-"
AIR OUTLET SWIT H IS SET TO
HEATING OPERATION
¥Asoperation starts, warm air is automatically discharged
from top and bottom side air outlets.
¥ Whentheroomtemperature reaches the preset temperature,
air is directed only from top side air outlet at the LOW fan
speed.
#
!/0"12 !03"1