manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hitachi
  6. •
  7. Air Conditioner
  8. •
  9. Hitachi RAM-68NP3B User manual

Hitachi RAM-68NP3B User manual

Other manuals for RAM-68NP3B

1

Other Hitachi Air Conditioner manuals

Hitachi RAI-50PPD User manual

Hitachi

Hitachi RAI-50PPD User manual

Hitachi RAS-NP4US Manual

Hitachi

Hitachi RAS-NP4US Manual

Hitachi airHome 300 User manual

Hitachi

Hitachi airHome 300 User manual

Hitachi RAS-30CHP6 User manual

Hitachi

Hitachi RAS-30CHP6 User manual

Hitachi RAS-63CHA3F User manual

Hitachi

Hitachi RAS-63CHA3F User manual

Hitachi RAD-50PPD User manual

Hitachi

Hitachi RAD-50PPD User manual

Hitachi UTOPIA R32 Series User manual

Hitachi

Hitachi UTOPIA R32 Series User manual

Hitachi RAS-18CH7 User manual

Hitachi

Hitachi RAS-18CH7 User manual

Hitachi RAS-10EX9K User manual

Hitachi

Hitachi RAS-10EX9K User manual

Hitachi RA-08KF Specification sheet

Hitachi

Hitachi RA-08KF Specification sheet

Hitachi RAS-60YHA4 User manual

Hitachi

Hitachi RAS-60YHA4 User manual

Hitachi RAK-18PEB User manual

Hitachi

Hitachi RAK-18PEB User manual

Hitachi airHome 400 User manual

Hitachi

Hitachi airHome 400 User manual

Hitachi RAK-18PSC User manual

Hitachi

Hitachi RAK-18PSC User manual

Hitachi MULTIZONE RAF-25RXE User manual

Hitachi

Hitachi MULTIZONE RAF-25RXE User manual

Hitachi Summit RAC-35YH6 User manual

Hitachi

Hitachi Summit RAC-35YH6 User manual

Hitachi RAS-50WX8 User manual

Hitachi

Hitachi RAS-50WX8 User manual

Hitachi RAS-S10HA User manual

Hitachi

Hitachi RAS-S10HA User manual

Hitachi YUTAKI Series Manual

Hitachi

Hitachi YUTAKI Series Manual

Hitachi RAK35NH4 User manual

Hitachi

Hitachi RAK35NH4 User manual

Hitachi RAS-(3-6)HVRNM2E User manual

Hitachi

Hitachi RAS-(3-6)HVRNM2E User manual

Hitachi PH Series User manual

Hitachi

Hitachi PH Series User manual

Hitachi RPF Series User manual

Hitachi

Hitachi RPF Series User manual

Hitachi RAK-AH10PCASM/RAC-AH10PCASM User manual

Hitachi

Hitachi RAK-AH10PCASM/RAC-AH10PCASM User manual

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Daikin R32 Split Series installation manual

Daikin

Daikin R32 Split Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

NO. 0585E
SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT
ROOM AIR CONDITIONER
OUTDOOR UNIT
JANUARY 2015
Refrigeration & Air-Conditioning Division
SERVICE MANUAL
PM
RAM-68NP3B
REFER TO THE FOUNDATION MANUAL
TECHNICAL INFORMATION
FOR SERVICE PERSONNEL ONLY
CONTENTS
SPECIFICATIONS---------------------------------------------------------------------5
FEATURES---------------------------------------------------------------------------- 10
INSTALLATION----------------------------------------------------------------------- 14
CONSTRUCTION AND DIMENSIONAL DIAGRAM ----------------------- 18
MAIN PARTS COMPONENT ---------------------------------------------------- 19
WIRING DIAGRAM ----------------------------------------------------------------- 21
CIRCUIT DIAGRAM ---------------------------------------------------------------- 23
BLOCK DIAGRAM ------------------------------------------------------------------ 25
BASIC MODE ------------------------------------------------------------------------ 27
REFRIGERATING CYCLE DIAGRAM----------------------------------------- 47
DESCRIPTION OF MAIN CIRCUIT OPERATION------------------------- 48
TROUBLE SHOOTING ------------------------------------------------------------ 82
PARTS LIST AND DIAGRAM---------------------------------------------------- 90
After installation
850
800
298
55
(W)
(A)
COOLING CAPACITY
DC INVERTER TRIPLE SYSTEM MULTI
TYPE
MODEL
POWER SOURCE
TOTAL INPUT
TOTAL AMPERES
SPECIFICATIONS
OUTDOOR UNIT
RAM-68NP3B
HEATING CAPACITY
DIMENSIONS (mm)
NET WEIGHT
1ø, 220 - 240V, 50/60Hz
W
H
D
(kg)
(kW)
(B.T.U.)
REFER TO THE SPECIFICATIONS PAGE
RAM-68NP3B
– 1 –
SAFETY DURING REPAIR WORK
1. In order to disassemble and repair
the unit in question, be sure to
disconnect the power cord plug
from the power outlet before starting
the work.
2. If it is necessary to replace any parts, they should be replaced with respective genuine parts for the unit,
and the replacement must be effected in correct manner according to the instructions in the Service Manual
of the unit.
If the contacts of electrical
parts are defective, replace the
electrical parts without trying to
repair them.
3. After completion of repairs, the initial state
should be restored.
4. Lead wires should be connected and laid as
in the initial state.
5. Modification of the unit by the user himself
should absolutely be prohibited.
6. Tools and measuring instruments for use in repairs or inspection should be accurately calibrated in advance.
7. In installing the unit having been repaired, be careful to prevent the occurence of any accident such as
electrical shock, leak of current, or bodily injury due to the drop of any part.
8. To check the insulation of the unit, measure the insulation resistance between the power cord plug and
grounding terminal of the unit. The insulation resistance should be 1M or more as measured by a 500V
DC megger.
9. The initial location of installation such as window, floor or the other should be checked for being and safe
enough to support the repaired unit again.
If it is found not so strong and safe, the unit should be installed at the initial location after reinforced or at
a new location.
10. Any inflammable object must not
be placed about the location of
installation.
11. Check the grounding to see whether
it is proper or not, and if it is found
improper, connect the grounding
terminal to the earth.





– 2 –
WORKING STANDARDS FOR PREVENTING BREAKAGE OF SEMICONDUCTORS
1. Scope
The standards provide for items to be generally observed in carrying and handling semiconductors in relative
manufacturers during maintenance and handling thereof. (They apply the same to handling of abnormal
goods such as rejected goods being returned).
2. Object parts
(1) Micro computer
(2) Integrated circuits (I.C.)
(3) Field-effective transistor (F.E.T.)
(4) P.C. boards or the like to which the parts mentioned in (1) and (2) of this paragraph are equipped.
3. Items to be observed in handling
(1) Use a conductive container for carrying and storing of parts. (Even rejected goods should be handled
in the same way).
Fig. 1. Conductive container
(2) When any part is handled uncovered (in counting, packing and the like), the handling person must always
use himself as a body earth. (Make yourself a body earth by passing 1M earth resistance through a
ring or bracelet).
(3) Be careful not to touch the parts with your clothing when you hold a part even if a body earth is being
taken.
(4) Be sure to place a part on a metal plate with grounding.
(5) Be careful not to fail to turn off power when you repair the printed circuit board. At the same time, try
to repair the printed circuit board on a grounded metal plate.
1M
Fig. 2. Body Earth
Body earth
(Elimik conductive band)
Clip for connection with a
grounding wire
IC
A conductive polyvinyl bag IC
Conductive sponge
– 3 –
(6) Use a three wire type soldering iron including a grounding wire.
Bare copper wire (for body earth)
Working table
Resistor 1 M (1/2W)
Earth wire
Fig. 3. Grounding of the working table
2
Screw stop at the screwed
part using a rag plate
Soldering iron
Grounding wire
Fig. 4. Grounding a solder iron
Use a high insulation mode (100V, 10M or higher) when ordinary iron is to be used.
(7) In checking circuits for maintenance, inspection or some others, be careful not to have the test probes of
the measuring instrument short circuit a load circuit or the like.
Metal plate (of aluminium, stainless steel, etc.)
Staple
– 4 –
1. In quiet or stop operation, slight flowing noise of refrigerant in the refrigerating cycle is heard occasionally,
but this noise is not abnormal for the operation.
2. When it thunders nearby, it is recommend to stop the operation and to disconnect the power cord plug
from the power outlet for safety.
3. In the event of power failure, the air conditioner will restart automatically in the previously selected mode
once the power is restored. In the event of power failure during TIMER operation, the air conditioner will
not start automatically. Re-press ON/OFF button after 3 minutes from when the unit off or power recovery.
4. If the room air conditioner is stopped by adjusting thermostat, or missoperation, and re-start in a moment,
there is occasion that the cooling and heating operation does not start for 3 minutes, it is not abnormal
and this is the result of the operation of IC delay circuit. This IC delay circuit ensures that there is no
danger of blowing fuse or damaging parts even if operation is restarted accidentally.
5. This room air conditioner should not be used at the cooling operation when the outside temperature is
below –10°C (14°F).
6. This room air conditioner (the reverse cycle) should not be used when the outside temperature is below
–15°C (5°F).
If the reverse cycle is used under this condition, the outside heat exchanger is frosted and efficiency falls.
7. When the outside heat exchanger is frosted, the frost is melted by operating the hot gas system, it is not
trouble that at this time fan stops and the vapour may rise from the outside heat exchanger.
!
CAUTION
– 5 –
SPECIFICATIONS
MODEL
FAN MOTOR
FAN MOTOR CAPACITOR
FAN MOTOR PROTECTOR
COMPRESSOR
COMPRESSOR MOTOR CAPACITOR
OVERLOAD PROTECTOR
OVERHEAT PROTECTOR
FUSE (for MICROPROCESSOR)
POWER RELAY
POWER SWITCH
TEMPORARY SWITCH
SERVICE SWITCH
TRANSFORMER
VARISTOR
NOISE SUPPRESSOR
THERMOSTAT
REMOTE CONTROL SWITCH (LIQUID CRYSTAL)
47 W
NO
NO
JU151XC1
NO
YES
YES
5.0A
G4A
NO
NO
YES
NO
450NR
YES
YES(IC)
NO
2300gUNIT
REFRIGERANT CHARGING
VOLUME
(Refrigerant R410A)
WITHOUT REFRIGERANT BECAUSE
COUPLING IS FLARE TYPE.
PIPES (MAX.)
In case the pipe length is more than 30m, add refrigerant R410 at 20gram per every meter exceeds.
RAM-68NP3B
MAX. 60m
– 6 –
SPECIFICATIONS FOR INDOOR UNITS COMBINATION
OPERATION SCOPE
TYPE
DC INVERTER TRIPLE SYSTEM MULTI COOLING AND HEATING
MODEL OUTDOOR UNIT
PHASE/VOLTAGE/FREQUENCY
CIRCUIT AMPERES TO CONNECT (A)
COOLING
(THREE
UNITS)
CAPACITY (kW)
(B.T.U./h)
TOTAL INPUT (W)
EER (B.T.U./hW)
TOTAL AMPERES (A)
POWER FACTOR (%)
HEATING
(THREE
UNITS)
CAPACITY (kW)
(B.T.U./h)
TOTAL INPUT (W)
EER (B.T.U./hW)
TOTAL AMPERES (A)
POWER FACTOR (%)
MAXIMUM LENGTH OF PIPING
STANDARD
RAM-68NP3B
1ø, 220 - 240V, 50/60Hz
20A
6.80
23,200
2,080
11.15
9.55 - 8.75
99
8.50
29,010
2,280
12.72
10.5 - 9.6
99
MAX. 60m (THREE UNIT TOTAL)
CE (EMC&LVD)
RAM-68NP3B
MODEL
W
PACKING
(mm)
H
D
cu.ft.
1,008
848
394
11.89
63
GROSS WEIGHT (kg)
(6.35DX4)/(9.52DX3)
FLARE NUT SIZE (SMALL/LARGE)
INDOOR SUCTION
TEMPERATURE (˚C)
COOLING OPERATION SCOPE
OUTDOOR SUCTION
TEMPERATURE (˚C)
INDOOR SUCTION
HUMIDITY (%)
HEATING OPERATION SCOPE
16 ~ 32 -10 ~ 43 BELOW 80
BELOW 27 –15 ~ 21—
3 ROOM MULTI-SPLIT INVERTER TYPE RAC: RAM-68NP3B
POSSIBLE COMBINATION TO OPERATE (SAME TIME OPERATION)
POWER POWER
CONSUMPTION 220 - 230 - 240 CONSUMPTION 220 - 230 - 240
TOTAL (W) TOTAL (W)
1.50 400 2.00 560
(200-480) (320-850)
450 720
(280-500) (320-1130)
650 980
(280-720) (320-1480)
1030 1150
(280-1130) (320-1950)
1450 2030
(280-1800) (320-2530)
1.5 + 1.5 1.50 + 1.50 870 2.00 + 2.00 4.00 1080
(380-980) (200-1100)
1.5 + 1.8 1.50 + 1.80 3.30 950 2.00 + 2.50 4.50 1200
(380-1000) (200-1300)
1.5 + 2.5 1.50 + 2.50 4.00 1150 2.00 + 3.40 5.40 1450
(380-1300) (200-1780)
1.5 + 3.5 1.50 + 3.50 5.00 1450 2.00 + 4.30 6.30 1660
(380-1450) (200-2010)
1.5 + 5.0 1.50 + 5.00 6.50 1950 2.00 + 6.50 8.50 2200
(380-2380) (390-3120)
1.8 + 1.8 1.80 + 1.80 1020 2.50 + 2.50 1380
(380-1020) (390-2750)
1.8 + 2.5 1.80 + 2.50 1120 2.50 + 3.40 1610
(380-1360) (390-3000)
1.8 + 3.5 1.80 + 3.50 1600 2.50 + 4.30 1850
(380-1950) (390-3120)
1.8 + 5.0 1.80 + 5.00 2050 2.36 + 6.14 2350
(380-2820) (390-3120)
2.5 + 2.5 2.50 + 2.50 1410 3.40 + 3.40 2000
(380-1720) (390-3120)
2.5 + 3.5 2.50 + 3.50 1850 3.40 + 4.30 2120
(380-2380) (390-3120)
2.5 + 5.0 2.40 + 4.70 2060 2.92 + 5.58 2350
(380-2980) (390-3120)
3.5 + 3.5 3.50 + 3.50 2060 4.25 + 4.25 2350
(380-2940) (390-3120)
3.5 + 5.0 2.90 + 4.20 2060 3.38 + 5.12 2350
(380-2890) (390-3120)
5.0 + 5.0 3.55 + 3.55 2060 4.25 + 4.25 8.50 2350
(380-3170) (390-3120)
1.5 + 1.5 + 1.5 1.50 + 1.50 + 1.50 1400 2.00 + 2.00 + 2.00 1650
(420-1680) (430-1800)
1.5 + 1.5 + 1.8 1.50 + 1.50 + 1.80 1480 2.00 + 2.00 + 2.50 6.50 1750
(240-1880) (430-2100)
1.5 + 1.5 + 2.5 1.50 + 1.50 + 2.50 1680 2.00 + 2.00 + 3.40 7.40 2010
(420-2280) (430-2200)
1.5 + 1.5 + 3.5 1.50 + 1.50 + 3.50 2010 2.00 + 2.00 + 4.30 8.30 2260
(420-2480) (430-2500)
1.5 + 1.5 + 5.0 1.28 + 1.28 + 4.25 2100 1.62 + 1.62 + 5.26 8.50 2300
(420-2890) (430-2600)
1.5 + 1.8 + 1.8 1.50 + 1.80 + 1.80 1550 2.00 + 2.50 + 2.50 7.00 1900
(420-2280) (430-2400)
1.5 + 1.8 + 2.5 1.50 + 1.80 + 2.50 1800 2.00 + 2.50 + 3.40 7.90 2150
(420-2480) (430-2600)
1.5 + 1.8 + 3.5 1.50 + 1.80 + 3.50 2100 1.93 + 2.41 + 4.15 8.50 2290
(420-2480) (430-2600)
1.5 + 1.8 + 5.0 1.23 + 1.47 + 4.10 2100 1.55 + 1.93 + 5.02 8.50 2290
(420-2890) (430-2600)
1.5 + 2.5 + 2.5 1.50 + 2.50 + 2.50 2020 1.93 + 3.28 + 3.28 8.50 2290
(420-2480) (430-2600)
1.5 + 2.5 + 3.5 1.36 + 2.27 + 3.17 2100 1.75 + 2.98 + 3.77 8.50 2290
(420-2890) (430-2600)
1.5 + 2.5 + 5.0 1.13 + 1.89 + 3.78 2100 1.43 + 2.43 + 4.64 8.50 2310
(420-2960) (430-2600)
1.5 + 3.5 + 3.5 1.20 + 2.80 + 2.80 2100 1.60 + 3.45 + 3.45 8.50 2310
(420-2890) (430-2600)
1.5 + 3.5 + 5.0 1.02 + 2.38 + 3.40 2100 1.33 + 2.86 + 4.32 8.50 2310
(420-2960) (430-2600)
1.8 + 1.8 + 1.8 1.80 + 1.80 + 1.80 1450 2.50 + 2.50 + 2.50 7.50 2050
(420-2190) (430-2600)
1.8 + 1.8 + 2.5 1.80 + 1.80 + 2.50 1720 2.50 + 2.50 + 3.40 8.40 2290
(420-2480) (430-2600)
1.8 + 1.8 + 3.5 1.72 + 1.72 + 3.35 2080 2.28 + 2.28 + 3.93 8.50 2290
(420-2890) (430-2600)
1.8 + 1.8 + 5.0 1.42 + 1.42 + 3.95 2080 1.85 + 1.85 + 4.80 8.50 2280
(420-2960) (430-2600)
1.8 + 2.5 + 2.5 1.80 + 2.50 + 2.50 2080 2.28 + 3.11 + 3.11 8.50 2290
(420-2780) (430-2600)
1.8 + 2.5 + 3.5 1.57 + 2.18 + 3.05 2080 2.08 + 2.83 + 3.58 8.50 2290
(420-2960) (430-2600)
1.8 + 2.5 + 5.0 1.32 + 1.83 + 3.66 2080 1.71 + 2.33 + 4.46 8.50 2280
(440-2770) (430-2600)
1.8 + 3.5 + 3.5 1.39 + 2.70 + 2.70 2080 1.91 + 3.29 + 3.29 8.50 2290
(420-2960) (430-2600)
1.8 + 3.5 + 5.0 1.19 + 2.31 + 3.30 2080 1.60 + 2.75 + 4.15 8.50 2280
(420-2960) (430-2600)
2.5 + 2.5 + 2.5 2.27 + 2.27 + 2.27 2080 2.83 + 2.83 + 2.83 8.50 2290
(420-2890) (430-2600)
2.5 + 2.5 + 3.5 2.00 + 2.00 + 2.80 2080 2.60 + 2.60 + 3.29 8.50 2290
(420-2960) (430-2600)
2.5 + 2.5 + 5.0 1.70 + 1.70 + 3.40 2080 2.17 + 2.17 + 4.15 8.50 2280
(420-2960) (430-2600)
2.5 + 3.5 + 3.5 1.79 + 2.51 + 2.51 2080 2.41 + 3.05 + 3.05 8.50 2290
(420-2960) (430-2600)
2.5 + 3.5 + 5.0 1.55 + 2.16 + 3.09 2080 2.04 + 2.57 + 3.89 8.50 2280
(420-2960) (430-2600)
3.5 + 3.5 + 3.5 2.27 + 2.27 + 2.27 2080 2.83 + 2.83 + 2.83 8.50 2280
(420-2960) (430-2600)
<REMARKS>
*
ONE UNIT INDICATED ARE ONLY FOR ONE UNIT OPERATION WHEN TWO OR THREE INDOOR UNITS ARE CONNECTED.
*
TWO UNITS INDICATED ARE ONLY FOR TWO UNIT OPERATION WHEN TWO OR THREE INDOOR UNITS ARE CONNECTED.
*
THREE UNITS INDICATED ARE ONLY FOR THREE UNIT OPERATION WHEN THREE INDOOR UNITS ARE CONNECTED.
*Total nominal coolin
g
ca
p
acit
y
should not be more than 11kW.
ONE UNIT
- 9.6 3.73 A
(2.20-8.00) (2.40-9.50)
3.27 A 10.5 - 10.0
(2.20-8.00) (2.40-9.50)
8.75
10.0-
10.5 6.80 9.55 - 9.13 -
- 9.6 3.73 A3.27 A 10.5
A
(2.20-8.00) (2.40-9.50)
11.0 6.80 9.55 - 9.13 - 8.75
- 10.1 - 9.6 3.718.8 3.27 A 10.59.5 6.80 9.6 - 9.1 -
(2.20-8.00) (2.40-9.50) - 9.6 3.73 A3.27 A 10.5 - 10.0
A
(2.20-8.00) (2.40-9.50)
10.0 6.80 9.6 - 9.1 - 8.8
- 10.1 - 9.6 3.718.8 3.27 A 10.58.5 6.80 9.6 - 9.1 -
3.71 A
(2.20-7.80) (2.40-9.50)
3.27 A
(2.20-8.00) (2.40-9.50)
7.5 6.80 9.6 - 9.1 - 8.8
- 9.6
10.5 - 10.1 - 9.6
3.73 A3.27 A 10.5 - 10.0
A
(2.20-8.00) (2.40-9.50)
10.3 6.80 9.6 - 9.1 - 8.8
- 10.1 - 9.6 3.718.8 3.27 A 10.58.8 6.80 9.6 - 9.1 -
(2.20-8.00) (2.40-9.50) - 9.6 3.73 A3.27 A 10.5 - 10.0
A
(2.20-8.00) (2.40-9.50)
9.3 6.80 9.6 - 9.1 - 8.8
- 10.1 - 9.6 3.718.8 3.27 A 10.57.8 6.80 9.6 - 9.1 -
3.71 A
(2.20-7.50) (2.40-9.50)
3.27 A6.8 6.80 9.6 - 9.1 - 8.8 10.5 - 10.1 - 9.6
A
(2.20-8.00) (2.40-9.50) - 10.0 - 9.6 3.738.8 3.27 A 10.58.6 6.80 9.6 - 9.1 -
3.71 A
(2.20-7.80) (2.40-9.50)
3.27 A
(2.20-6.70) (2.40-9.50)
7.1 6.80 9.6 - 9.1 - 8.8
- 9.6
10.5 - 10.1 - 9.6
3.67 A3.55 A 10.5 - 10.1
A
(2.20-5.90) (2.40-9.50)
6.1 6.10 7.9 - 7.6 - 7.2
- 9.0 - 8.6 3.666.1 3.72 A 9.45.4 5.40 6.7 - 6.4 -
3.68 A
(2.20-8.00) (2.40-9.50)
3.24 A
(2.20-8.00) (2.40-9.50)
10.0 6.80 9.6 - 9.2 - 8.8
- 9.7
10.6 - 10.1 - 9.7
3.68 A3.24 A 10.6 - 10.18.5 6.80 9.6 - 9.2 - 8.8
3.68 A
(2.20-8.00) (2.40-9.50)
3.24 A
(2.20-7.80) (2.40-9.50)
9.0 6.80 9.6 - 9.2 - 8.8
- 9.6
10.6 - 10.1 - 9.7
3.71 A3.24 A 10.5 - 10.1
A
(1.50-7.00) (2.40-9.50)
7.5 6.80 9.6 - 9.2 - 8.8
- 10.1 - 9.6 3.718.5 3.22 A 10.56.5 6.50 9.3 - 8.9 -
(2.20-7.50) (2.40-9.50) - 9.6 3.71 A3.24 A 10.5 - 10.1
(2.20-7.50) (2.40-9.50)
8.3 6.80 9.6 - 9.2 - 8.8
10.1 - 9.6 3.71 A3.24 A 10.5 -
A
(2.20-6.30) (2.40-9.50)
6.8 6.80 9.6 - 9.2 - 8.8
- 9.4 - 9.0 3.677.6 3.22 A 9.95.8 5.80 8.3 - 7.9 -
3.68 A
(2.20-5.60) (2.20-9.30)
3.29 A5.1 5.10 7.1 - 6.8 - 6.5 8.7 - 8.3 - 8.0
A
(2.20-7.50) (2.40-9.50) - 10.1 - 9.7 3.708.8 3.24 A 10.68.0 6.80 9.6 - 9.2 -
3.67 A
(2.20-7.00) (2.40-9.50)
3.23 A
(2.20-6.00) (2.20-9.30)
6.5 6.50 9.2 - 8.8 - 8.5
- 8.5
10.4 - 9.9 - 9.5
3.68 A3.27 A 9.2 - 8.8
A
(2.20-5.50) (2.40-7.00)
5.5 5.50 7.7 - 7.4 - 7.1
- 7.7 - 7.4 3.716.2 3.24 A 8.0
3.64 A
(2.20-5.00) (2.40-6.50)
4.8 4.80 6.8 - 6.5 -
7.6 - 7.2 - 6.95.9 3.21 A 6.004.5 4.50 6.4 - 6.1 -
THREE UNITS
A
(2.00-8.00) (2.20-9.50) - 10.3 - 9.9 3.628.7 3.30 A 10.810.0 6.80 9.5 - 9.0 -
3.62 A
(2.00-7.50) (2.20-9.50) 10.8 - 10.3 - 9.98.7 3.30 A 8.50
3.62 A
(2.00-7.40) (2.20-9.50)
8.5 6.80 9.5 - 9.0 -
10.8 - 10.3 - 9.98.7 3.30 A 8.507.0 6.80 9.5 - 9.0 -
3.62 A
(2.00-7.50) (2.20-9.50) 10.8 - 10.3 - 9.98.7 3.30 A 8.50
3.63 A
(2.00-6.60) (2.20-9.50)
7.5 6.80 9.5 - 9.0 -
9.7 - 9.3 - 8.97.8 3.24 A 7.70
3.40 B
(2.00-5.50) (2.20-9.50)
6.0 6.00 8.5 - 8.1 -
9.2 - 8.8 - 8.45.9 3.55 A 6.805.0 5.00 6.5 - 6.2 -
3.62 A
(2.00-7.10) (2.20-9.50) 10.8 - 10.3 - 9.98.6 3.32 A 8.50
3.68 A
(2.00-5.80) (2.20-7.20)
6.8 6.80 9.4 - 9.0 -
8.5 - 8.1 - 7.86.7 3.31 A 6.80
3.66 A
(2.00-4.70) (2.20-7.20)
5.3 5.30 7.3 - 7.0 -
7.4 - 7.1 - 6.84.7 3.84 A 5.90
3.62 A
(2.00-4.00) (2.20-6.40)
4.3 4.30 5.1 - 4.9 -
6.3 - 6.1 - 5.84.3 3.53 A 5.003.6 3.60 4.7 - 4.5 -
9.7 - 9.3 3.86 A3.33 A 10.1 -
(2.20-7.20)
6.5 9.0 - 8.6 - 8.2
(1.50-5.90)
7.3 - 7.0 3.80 A3.45 A 7.6 -
(2.20-7.20)
5.0 6.7 - 6.4 - 6.1
(1.50-5.20)
6.4 - 6.1 3.72 A3.48 A 6.7 -
(2.20-6.40)
4.0 5.3 - 5.1 - 4.8
(1.50-4.00)
- 5.1 3.75 A
(1.50-3.50) (2.20-5.20)
3.47 A 5.5 - 5.3
A
(1.50-2.80) (2.20-4.70) - 4.7 -
3.3 4.4 - 4.2 - 4.0
4.5 3.703.7 3.45 A 5.03.0 3.00 4.0 - 3.8 -
TWO UNITS
8.9 - 8.5 3.20 C
6.50 6.50 9.3 -
(1.80-7.20)
6.4 - 6.1 3.45 A5.0 5.0 5.00 5.00 6.7 -
(1.50-5.60)
5.1 - 4.8 3.74 A
4.30 4.30 5.3 -
(1.80-5.80)
4.5 - 4.3 3.40 A3.5 3.5 3.50 3.50 4.7 -
(1.50-3.90)
4.3 - 4.1 3.47 B
3.40 3.40 4.5 -
(1.80-4.70)
2.9 - 2.7 3.85 A2.5 2.5 2.50 2.50 3.0 -
(1.50-2.80)
3.0 3.47 B
(1.50-2.00) (1.80-3.50)
2.50 2.50 3.3 -2.0 - 3.2 -1.9 4.00 A1.8 1.8 1.80 1.80 2.1 -
- 2.4 3.57 B
(1.00-1.60) (1.10-2.20)
2.00 2.6 - 2.51.8 - 1.7 3.75 A1.5 1.5 1.50 1.8 -
COP
energy
efficie
ncy
class
RATING (kW) AMPERE (A) at RATING (kW) AMPERE (A) at
(RANGE) (RANGE)
POSSIBLE COMBINATIONS TO
OPERATE
COOLING HEATING
CAPACITY OUTDOOR UNIT
EER
energy
efficie
ncy
class
CAPACITY OUTDOOR UNIT
– 9 –
TRIPLE SYSTEM MULTI R.A.C. RAM-68NP3B INDOOR UNITS
COMBINATIONS TO BE ABLE TO INSTALL
Two or three indoor units can be installed with one outdoor unit. And
total nominal cooling capacity should not be more than 11.0kW
Be sure to connect two or three indoor units to this outdoor unit. If not, condensed water may drop,
resulting in trouble.
– 10 –
TRIPLE RAM-68NP3B
No.1 No.2 No.3
6.35/9.52D 6.35/9.52D 6.35/9.52D
1.5 1.5
1.5 1.8
1.5 2.5
1.5 3.5
1.5 ⊙ 5.0
1.8 1.8
1.8 2.5
1.8 3.5
1.8 ⊙ 5.0
2.5 2.5
2.5 3.5
2.5 ⊙ 5.0
3.5 3.5
3.5 ⊙ 5.0
⊙ 5.0 ⊙ 5.0
1.5 1.5 1.5
1.5 1.5 1.8
1.5 1.5 2.5
1.5 1.5 3.5
1.5 1.5 ⊙ 5.0
1.5 1.8 1.8
1.5 1.8 2.5
1.5 1.8 3.5
1.5 1.8 ⊙ 5.0
1.5 2.5 2.5
1.5 2.5 3.5
1.5 2.5 ⊙ 5.0
1.5 3.5 3.5
1.5 3.5 ⊙ 5.0
1.8 1.8 1.8
1.8 1.8 2.5
1.8 1.8 3.5
1.8 1.8 ⊙ 5.0
1.8 2.5 2.5
1.8 2.5 3.5
1.8 2.5 ⊙ 5.0
1.8 3.5 3.5
1.8 3.5 ⊙ 5.0
2.5 2.5 2.5
2.5 2.5 3.5
2.5 2.5 ⊙ 5.0
2.5 3.5 3.5
2.5 3.5 ⊙ 5.0
3.5 3.5 3.5
CONNECTING POSITION ON OUTDOOR
UNIT (VALVE DIAMETER)(mm)
2.5 3.5 5.0 (8 ~ 12) (9 ~ 15) (14 ~ 21)
3.5 3.5 3.5 (11 ~ 16) (11 ~ 16) (11 ~ 16)
2.5 2.5 5.0 (8 ~ 12) (8 ~ 12) (16 ~ 24)
2.5 3.5 3.5 (8 ~ 13) (11 ~ 17) (11 ~ 17)
2.5 2.5 2.5 (11 ~ 16) (11 ~ 16) (11 ~ 16)
2.5 2.5 3.5 (9 ~ 14) (9 ~ 14) (12 ~ 19)
1.8 3.5 3.5 (7 ~ 11) (12 ~ 19) (12 ~ 19)
1.8 3.5 5.0 (6 ~ 10) (11 ~ 16) (15 ~ 23)
1.8 2.5 3.5 (8 ~ 12) (9 ~ 15) (14 ~ 21)
1.8 2.5 5.0 (7 ~ 11) (8 ~ 13) (17 ~ 25)
1.8 1.8 5.0 (7 ~ 11) (7 ~ 11) (18 ~ 27)
1.8 2.5 2.5 (8 ~ 12) (11 ~ 17) (11 ~ 17)
1.8 1.8 2.5 (8 ~ 12) (8 ~ 12) (11 ~ 17)
1.8 1.8 3.5 (8 ~ 12) (8 ~ 12) (15 ~ 23)
1.5 3.5 5.0 (6 ~ 9) (16 ~ 24) (16 ~ 24)
1.8 1.8 1.8 (8 ~ 12) (8 ~ 12) (8 ~ 12)
1.5 2.5 5.0 (6 ~ 10) (8 ~ 13) (18 ~ 26)
1.5 3.5 3.5 (6 ~ 10) (12 ~ 19) (12 ~ 19)
1.5 2.5 2.5 (8 ~ 12) (11 ~ 17) (11 ~ 17)
1.5 2.5 3.5 (7 ~ 11) (11 ~ 16) (14 ~ 22)
1.5 1.8 3.5 (8 ~ 12) (8 ~ 12) (16 ~ 24)
1.5 1.8 5.0 (7 ~ 10) (8 ~ 12) (19 ~ 28)
1.5 1.5 5.0 (7 ~ 11) (7 ~ 11) (20 ~ 29)
1.5 1.8 1.8 (8 ~ 12) (8 ~ 12) (8 ~ 12)
1.5 1.8 2.5 (8 ~ 12) (8 ~ 12) (11 ~ 17)
THREE UNITS
1.5 1.5 1.5 (8 ~ 12) (8 ~ 12) (8 ~ 12)
1.5 1.5 1.8 (8 ~ 12) (8 ~ 12) (8 ~ 12)
1.5 1.5 2.5 (8 ~ 12) (8 ~ 12) (11 ~ 17)
3.5 5.0 (12 ~ 19) (19 ~ 27)
5.0 5.0 (16 ~ 24) (16 ~ 24)
2.5 5.0 (9 ~ 15) (22 ~ 31)
3.5 3.5 (16 ~ 24) (16 ~ 24)
1.5 1.5 3.5 (8 ~ 12) (8 ~ 12) (16 ~ 24)
2.5 2.5 (11 ~ 17) (11 ~ 17)
2.5 3.5 (11 ~ 17) (16 ~ 24)
1.8 3.5 (8 ~ 12) (16 ~ 24)
1.8 5.0 (8 ~ 12) (23 ~ 34)
1.8 1.8 (8 ~ 12) (8 ~ 12)
1.8 2.5 (8 ~ 12) (11 ~ 17)
1.5 3.5 (8 ~ 12) (16 ~ 24)
1.5 5.0 (8 ~ 12) (23 ~ 34)
1.5 1.8 (8 ~ 12) (8 ~ 12)
1.5 2.5 (8 ~ 12) (11 ~ 17)
POSSIBLE COMBINATIONS TO
INSTALL (kW) SUITABLE ROOM SIZE TO INSTALL (m²)
TWO UNITS
1.5 1.5 (8 ~ 12) (8 ~ 12)
1.5, 2.5, 3.5 & 5.0