manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HomeSeer
  6. •
  7. Accessories
  8. •
  9. HomeSeer HS-LS100+ User manual

HomeSeer HS-LS100+ User manual

Other HomeSeer Accessories manuals

HomeSeer HS-FLS100-G2 Operator's manual

HomeSeer

HomeSeer HS-FLS100-G2 Operator's manual

HomeSeer HSM200 User manual

HomeSeer

HomeSeer HSM200 User manual

HomeSeer HS-FLS100+ User manual

HomeSeer

HomeSeer HS-FLS100+ User manual

HomeSeer HS-MS100+ User manual

HomeSeer

HomeSeer HS-MS100+ User manual

HomeSeer HS-DS100PLUS User manual

HomeSeer

HomeSeer HS-DS100PLUS User manual

HomeSeer HS-LS100+ User manual

HomeSeer

HomeSeer HS-LS100+ User manual

HomeSeer Flex Sensor HS-FS100+ User manual

HomeSeer

HomeSeer Flex Sensor HS-FS100+ User manual

HomeSeer HS-DS100+ User manual

HomeSeer

HomeSeer HS-DS100+ User manual

HomeSeer HS-FS100+ User manual

HomeSeer

HomeSeer HS-FS100+ User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

HomeSeer | 10 Commerce Park North, Unit 10 | Bedford, NH 03110 | HomeSeer.com | Doc: HS-LS100-en-v1.0a
HS-LS100+ Z-Wave Leak Sensor
Applicaons
• Use to acvate Z-Wave devices such as sirens or water valve controllers when a leak is sensed.
• Use to trigger home automaon events (aka “scenes”, “automaons” or “robots”) when a leak is sensed.
Conguraon
HS-LS100+ is baery powered and includes a Z-Wave network buon, LED indicator and a magnec wall mount/wired probe
assembly. The unit may be deployed as a free-standing sensor (using built-in probes) or as a wired remote sensor (via the wall
mount/wired probe assembly).
Z-Wave Network Installaon
Remove the back cover by rotang counter-clockwise and install 1 ER14250 baery (included) inside HS-LS100+. Include the
sensor into your Z-Wave network using the instrucons below. Then, replace the back cover.
Note: HS-LS100+ may be included into your Z-Wave network as a “secure” device or as a “non-secure” device. Use the
instrucons below to include or exclude HS-LS100+ to/from your Z-Wave network.
Secure Inclusion (recommended if your home controller supports “S0” or “S2” Z-Wave encrypon)
1. Put your home controller into Z-Wave ‘inclusion’ mode.
2. Press and hold the Z-Wave network buon for 5 seconds, then release it. Wait for the inclusion process to nish.
Non-Secure Inclusion
1. Put your home controller into Z-Wave ‘inclusion’ mode.
2. Quickly press and release the Z-Wave network buon once. Wait for the inclusion process to nish.
Exclusion
1. Put your home automaon controller into Z-Wave ‘exclusion’ mode.
2. Quickly triple-press the Z-Wave network buon. Wait for the exclusion process to nish.
Reset (Use this procedure to reset HS-LS100+ to factory sengs when the Z-Wave controller is missing or inoperable).
1. Press and hold the Z-Wave buon for 20 seconds. Release the buon once the LED stops blinking and glows solidly.
Physical Installaon
Free-standing installaon: Simply place the leak sensor on a at horizontal surface in the area where a leak might occur.
Remote installaon: Install the included magnec wall mount/wired probe assembly in the locaon of your choice (using the
supplied mounng hardware) and aach the HS-LS100+ to it by aligning the 3 probes with the 3 holes in the mounng bracket.
Posion and install the wired probe in the area where a leak might occur or where you wish to detect liquid.
Leak Sensor Operaon
HS-LS100+ is designed to transmit a Z-Wave command when liquid is sensed. It will also transmit another command when
liquid is no longer sensed.
Shock Sensor Operaon
The shock sensor is designed to transmit a Z-Wave command when HS-LS100+ has been physically moved. This sensor is
especially helpful in determining whether the unit has been removed from its mount or tampered with.
OVERVIEW
HS-LS100+ is a compact, easy to install leak sensor. It is designed to control other Z-Wave devices directly or it may be used
with a variety of Z-Wave cered home controllers to launch automaon events or scenes.
HomeSeer | 10 Commerce Park North, Unit 10 | Bedford, NH 03110 | HomeSeer.com | Doc: HS-LS100-en-v1.0a
ADVANCED CONFIGURATION (accessible via the “Root device” in a HomeSeer System. Before adjusng these sengs, tap the
network buon 4 mes to wake the unit.)
Parameter Sengs Parameter Sengs
14
Enable / Disable Basic Set Command
Available: 0=disable, 1=enable
Default: 0 | Size: 1 byte
20
Set High Temperature Trigger Value
Available: -670 to 2570 (-67 to 257 °F)
Default: 1040 (104 °F) | Size: 2 bytes
15
Set Value for Basic Set Command
Available: 0=Sends 255 value when leak sensed
Available: 1=Sends 0 value when leak sensed
Default: 0 | Size: 1 byte
22
Set Low Temperature Trigger Value
Available: -670 to 2570 (-67 to 257 °F)
Default: 320 (32 °F) | Size: 2 bytes
17
Leak Report Interval
Available: 0=disable, 1 to 255 (minutes)
Default: 5 | Size: 1 byte
24
Enable Blinking LED When Alarm Triggers
Available: 0=disable, 1=enable
Default: 1 | Size: 1 byte
18
Enable Shock Sensor
Available: 0=disable, 1=enable
Default: 0 | Size: 1 byte
32
Set Value for Low Baery
Available: 10-50 (%)
Default: 20 (%) | Size: 1 byte
19
Temperature Report Interval
Available: 0=disable, 1 to 255 (minutes)
Default: 0 | Size: 1 byte
Note: Parameter 18 (“Enable Shock Sensor”) and parameter 19
(“Temperature Report Interval”) are disabled by default, to
conserve baery life.
LIMITED WARRANTY
HomeSeer Technologies, LLC will repair or replace, at its opon, any part of the device, which proves to be defecve in workmanship or
material under normal use, in the USA except in the states of Alaska or Hawaii, for a period of one year from the date the device is
purchased. During the warranty period, HomeSeer Technologies, LLC will repair and provide all parts necessary to correct such defects, free
of charge, provided the device has been operated in accordance with the manufacturer's guidelines. The Customer will return the device to
HomeSeer Technologies, LLC for tesng and repair or replacement. Should you need service, during warranty period or beyond, contact
HomeSeer to obtain return authorizaon before shipping your device to HomeSeer Technologies, LLC.
SPECIFICATIONS
Operang Temp Range 0ºC to 40ºC Power Requires (1) ER14250 Baery
Z-Wave Frequency | Range
Z-Wave Cercaon
908 MHz (US) | Up To 300 Ft line of sight
Z-Wave Plus
Dimensions Sensor (main unit): 2.75 x 2.75 x .75 (inches)
Baery Sensor Operaon
The baery sensor is designed to report baery level with a Z-Wave command every 43200 seconds (12 hours). If desired,
HomeSeer users can adjust this interval (0-2678400 seconds) by accessing the sengs on the Z-Wave tab of the root device.
Z-Wave Associaon Informaon
HS-LS100+ supports Group 1 associaon. Group 1 reports the sensor’s status and baery if running on baeries.
Notes
• If your home controller supports “S2” security encrypon, the Leak Sensor may be added as a ‘secure’ device to your
network. If not, it will add as a non-secure device. This will not eect the funconality of the unit.
• For more informaon, visit homeseer.com.