Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway
24V
Dimensional drawings:
Installation:
Step 1: Install the mounting bracket to the wall/ceiling. Connect the 24V cable to C1 and C2 on the terminal
block, GND is optional. If surface-mounted cables are used, trim the knock-out opening in the luminaire.
Step 2: Hook the luminaire onto the “hinge” on the bracket and swing inwards until it locks.
Service/maintenance:
Step 3: First, remove the lens by carefully using a flat-bladed screwdriver at the marked positions.
Step 4: Then, use a flat-bladed screwdriver to remove the luminaire housing from the socket.
At the end of their useful life the
packaging and product should be
disposed of via a suitable
recycling centre. Do not dispose
of with your normal household
waste. Do not burn.
Lumen output: 210 lm
Operation voltage: 17-45V DC / 1 - 5V AC 50/60Hz
Maximum power consumption: W / 4.5VA
Ambient temperature range: -20 to +50°C
Relative humidity: Up to 95%
Weight: 800g
Classification: EN 60598-2-22
IP20